Format
Sort by
Items per page

Send to

Choose Destination

Links from PubMed

Items: 1 to 20 of 133

1.

Initial experience with the Evolution mechanical dilator sheath for lead extraction: safety and efficacy.

Hussein AA, Wilkoff BL, Martin DO, Karim S, Kanj M, Callahan T, Baranowski B, Saliba WI, Wazni OM.

Heart Rhythm. 2010 Jul;7(7):870-3. doi: 10.1016/j.hrthm.2010.03.019. Epub 2010 Mar 23.

PMID:
20346418
2.

Evolution in transvenous extraction of pacemaker and implantable cardioverter defibrillator leads using a mechanical dilator sheath.

Oto A, Aytemir K, Canpolat U, Yorgun H, Şahiner L, Kaya EB, Kabakçi G, Tokgözoğlu L.

Pacing Clin Electrophysiol. 2012 Jul;35(7):834-40. doi: 10.1111/j.1540-8159.2012.03385.x. Epub 2012 Apr 5.

PMID:
22486778
3.

Initial experience with the TightRail™ Rotating Mechanical Dilator Sheath for transvenous lead extraction.

Aytemir K, Yorgun H, Canpolat U, Şahiner ML, Kaya EB, Evranos B, Özer N.

Europace. 2016 Jul;18(7):1043-8. doi: 10.1093/europace/euv245. Epub 2015 Oct 14.

PMID:
26467403
4.

Percutaneous extraction of cardiac pacemaker and implantable cardioverter defibrillator leads with evolution mechanical dilator sheath: a single-centre experience.

Oto A, Aytemir K, Yorgun H, Canpolat U, Kaya EB, Kabakçı G, Tokgözoğlu L, Özkutlu H.

Europace. 2011 Apr;13(4):543-7. doi: 10.1093/europace/euq400. Epub 2010 Nov 17.

PMID:
21084359
5.

Initial experience of pacemaker and implantable cardioverter defibrillator lead extraction with the new GlideLight 80 Hz laser sheaths.

Hakmi S, Pecha S, Sill B, Reiter B, Willems S, Aydin MA, Yildirim Y, Reichenspurner H, Treede H.

Interact Cardiovasc Thorac Surg. 2014 Jan;18(1):56-60. doi: 10.1093/icvts/ivt428. Epub 2013 Sep 30.

6.

Lead extraction: a new effective tool to overcome fibrous binding sites.

Dello Russo A, Biddau R, Pelargonio G, Casella M, Frontera A, Camporeale A, Bisceglia C, Forleo GB, Tondo C, Zecchi P, Bellocci F.

J Interv Card Electrophysiol. 2009 Mar;24(2):147-50. doi: 10.1007/s10840-008-9326-y. Epub 2008 Nov 6.

PMID:
18987963
7.

Clinical performance of a new bidirectional rotational mechanical lead extraction sheath.

Starck CT, Steffel J, Caliskan E, Holubec T, Schoenrath F, Maisano F, Falk V.

Europace. 2016 Feb;18(2):253-6. doi: 10.1093/europace/euv126. Epub 2015 May 19.

PMID:
25995394
8.

Initial experience using Excimer laser for the extraction of chronically implanted pacemaker and implantable cardioverter defibrillator leads in Japanese patients.

Okamura H, Yasuda S, Sato S, Ogawa K, Nakajima I, Noda T, Shimahara Y, Hayashi T, Onishi Y, Kobayashi J, Kamakura S, Ogawa H, Shimizu W.

J Cardiol. 2013 Sep;62(3):195-200. doi: 10.1016/j.jjcc.2013.03.012. Epub 2013 May 30.

9.

Large, single-center, single-operator experience with transvenous lead extraction: outcomes and changing indications.

Jones SO 4th, Eckart RE, Albert CM, Epstein LM.

Heart Rhythm. 2008 Apr;5(4):520-5. doi: 10.1016/j.hrthm.2008.01.009. Epub 2008 Jan 17.

PMID:
18325849
10.

Advanced techniques for chronic lead extraction: heading from the laser towards the evolution system.

Mazzone P, Tsiachris D, Marzi A, Ciconte G, Paglino G, Sora N, Gulletta S, Vergara P, Della Bella P.

Europace. 2013 Dec;15(12):1771-6. doi: 10.1093/europace/eut126. Epub 2013 May 3.

PMID:
23645529
11.

Lead extractions: the Zwolle experience with the Evolution mechanical sheath.

Delnoy PP, Witte OA, Adiyaman A, Ghani A, Smit JJ, Ramdat Misier AR, Elvan A.

Europace. 2016 May;18(5):762-6. doi: 10.1093/europace/euv243. Epub 2015 Oct 14.

PMID:
26467401
12.

[Evaluation of lead extraction procedures using the Evolution Mechanical Dilatator Sheath lead extraction system: A single centre experience].

Kocabaş U, Duygu H, Eren NK, Akyıldız Zİ, Özyıldırım S, Tülüce SY, Nazlı C.

Turk Kardiyol Dern Ars. 2015 Jun;43(4):350-5. doi: 10.5543/tkda.2015.76329. Turkish.

13.

Transvenous extraction of pacemaker and implantable cardioverter defibrillator leads using Evolution® mechanical dilator sheath: a single center confirmatory experience.

Kocabaş U, Duygu H, Eren NK, Akyıldız Zİ, Özyıldırım S, Tülüce SY, Kırış T, Nazlı C.

Springerplus. 2016 Mar 22;5:356. doi: 10.1186/s40064-016-1987-x. eCollection 2016.

15.
16.

Transvenous extraction of implantable cardioverter-defibrillator leads under advisory--a comparison of Riata, Sprint Fidelis, and non-recalled implantable cardioverter-defibrillator leads.

Brunner MP, Cronin EM, Jacob J, Duarte VE, Tarakji KG, Martin DO, Callahan T, Borek PP, Cantillon DJ, Niebauer MJ, Saliba WI, Kanj M, Wazni O, Baranowski B, Wilkoff BL.

Heart Rhythm. 2013 Oct;10(10):1444-50. doi: 10.1016/j.hrthm.2013.06.021. Epub 2013 Jun 28.

PMID:
23816440
17.

Clinical study of the laser sheath for lead extraction: the total experience in the United States.

Byrd CL, Wilkoff BL, Love CJ, Sellers TD, Reiser C.

Pacing Clin Electrophysiol. 2002 May;25(5):804-8.

PMID:
12049372
18.

Single-operator experience with a mechanical approach for removal of pacing and implantable defibrillator leads.

Calvagna GM, Evola R, Scardace G, Valsecchi S.

Europace. 2009 Nov;11(11):1505-9. doi: 10.1093/europace/eup222. Epub 2009 Aug 7.

PMID:
19666895
19.

Safety and efficacy of the new bidirectional rotational Evolution® mechanical lead extraction sheath: results from a multicentre Italian registry.

Mazzone P, Migliore F, Bertaglia E, Facchin D, Daleffe E, Calzolari V, Crosato M, Melillo F, Peruzza F, Marzi A, Sora N, Della Bella P.

Europace. 2017 Feb 23. doi: 10.1093/europace/eux020. [Epub ahead of print]

PMID:
28339758
20.

Supplemental Content

Support Center