Format
Sort by

Send to

Choose Destination

Links from PubMed

Items: 1 to 20 of 495

1.

A comparison of transmittance and reflectance pulse oximetry during vascular surgery.

Wax DB, Rubin P, Neustein S.

Anesth Analg. 2009 Dec;109(6):1847-9. doi: 10.1213/ANE.0b013e3181bbc446.

PMID:
19923513
2.

Evaluation of oesophageal pulse oximetry in patients undergoing cardiothoracic surgery.

Kyriacou PA, Powell SL, Jones DP, Langford RM.

Anaesthesia. 2003 May;58(5):422-7.

3.

Comparison of forehead and digit oximetry in surgical/trauma patients at risk for decreased peripheral perfusion.

Schallom L, Sona C, McSweeney M, Mazuski J.

Heart Lung. 2007 May-Jun;36(3):188-94.

PMID:
17509425
4.

Forehead is as sensitive as finger pulse oximetry during general anesthesia.

Sugino S, Kanaya N, Mizuuchi M, Nakayama M, Namiki A.

Can J Anaesth. 2004 May;51(5):432-6.

PMID:
15128627
5.

Forehead reflectance oximetry: a clinical comparison with conventional digit sensors during laparotomic and laparoscopic abdominal surgery.

Casati A, Squicciarini G, Baciarello M, Putzu M, Salvadori A, Fanelli G.

J Clin Monit Comput. 2007 Oct;21(5):271-6.

PMID:
17701387
6.

Pulse oximetry and high-dose vasopressors: a comparison between forehead reflectance and finger transmission sensors.

Nesseler N, Frénel JV, Launey Y, Morcet J, Mallédant Y, Seguin P.

Intensive Care Med. 2012 Oct;38(10):1718-22.

PMID:
22868275
7.

[Comparison of a reflectance sensor and a transmittance sensor for pulse oximetry].

Sato N, Yasumoto K, Hosoyamada A.

Masui. 1994 Feb;43(2):262-7. Japanese.

PMID:
8164335
8.

Limitations of forehead pulse oximetry.

Jørgensen JS, Schmid ER, König V, Faisst K, Huch A, Huch R.

J Clin Monit. 1995 Jul;11(4):253-6.

PMID:
7561999
9.

Continuous noninvasive hemoglobin monitoring during complex spine surgery.

Berkow L, Rotolo S, Mirski E.

Anesth Analg. 2011 Dec;113(6):1396-402. doi: 10.1213/ANE.0b013e318230b425.

PMID:
21965372
10.

Evaluation of oesophageal reflectance pulse oximetry in major burns patients.

Pal SK, Kyriacou PA, Kumaran S, Fadheel S, Emamdee R, Langford RM, Jones DP.

Burns. 2005 May;31(3):337-41.

PMID:
15774290
11.

Pulse oximeter probes. A comparison between finger, nose, ear and forehead probes under conditions of poor perfusion.

Clayton DG, Webb RK, Ralston AC, Duthie D, Runciman WB.

Anaesthesia. 1991 Apr;46(4):260-5.

12.

Accuracy of pulse oximetry in hypothermic neonates and infants undergoing cardiac surgery.

Iyer P, McDougall P, Loughnan P, Mee RB, Al-Tawil K, Carlin J.

Crit Care Med. 1996 Mar;24(3):507-11.

PMID:
8625642
13.

Accuracy of continuous central venous oxygen saturation monitoring in patients undergoing cardiac surgery.

Baulig W, Dullenkopf A, Kobler A, Baulig B, Roth HR, Schmid ER.

J Clin Monit Comput. 2008 Jun;22(3):183-8. doi: 10.1007/s10877-008-9123-2.

PMID:
18443743
14.

The revised digital transcutaneous PCO2/SpO2 ear sensor is a reliable noninvasive monitoring tool in patients after cardiac surgery.

Roediger R, Beck-Schimmer B, Theusinger OM, Rusch D, Seifert B, Spahn DR, Schmid ER, Baulig W.

J Cardiothorac Vasc Anesth. 2011 Apr;25(2):243-9. doi: 10.1053/j.jvca.2010.06.021.

PMID:
20851636
15.

Reflectance pulse oximetry from core body in neonates and infants: comparison to arterial blood oxygen saturation and to transmission pulse oximetry.

Kugelman A, Wasserman Y, Mor F, Goldinov L, Geller Y, Bader D.

J Perinatol. 2004 Jun;24(6):366-71.

PMID:
15057251
16.
17.

Esophageal pulse oximetry utilizing reflectance photoplethysmography.

Kyriacou PA, Powell S, Langford RM, Jones DP.

IEEE Trans Biomed Eng. 2002 Nov;49(11):1360-8.

PMID:
12450366
18.

[Reliability of pulsatile saturometry in patients with shock. Digital standard sensors are not reliable for facial measurement!].

Joly LM, Guyomarc'h L, Damm C, Dureuil B, Veber B.

Ann Fr Anesth Reanim. 2012 Jan;31(1):41-6. doi: 10.1016/j.annfar.2011.07.019. French.

PMID:
22118873
19.

Evaluation of a new combined transcutaneous measurement of PCO2/pulse oximetry oxygen saturation ear sensor in newborn patients.

Bernet-Buettiker V, Ugarte MJ, Frey B, Hug MI, Baenziger O, Weiss M.

Pediatrics. 2005 Jan;115(1):e64-8.

PMID:
15601814
20.

Influence of digital clubbing on oxygen saturation measurements by pulse-oximetry in cystic fibrosis patients.

Van Ginderdeuren F, Van Cauwelaert K, Malfroot A.

J Cyst Fibros. 2006 May;5(2):125-8.

Items per page

Supplemental Content

Support Center