Format
Sort by
Items per page

Send to

Choose Destination

Links from PubMed

Items: 1 to 20 of 134

1.

MREIT with SENSE acceleration using a dedicated RF coil design.

Muftuler LT, Chen G, Hamamura MJ, Ha SH.

Physiol Meas. 2009 Sep;30(9):913-29. doi: 10.1088/0967-3334/30/9/004. Epub 2009 Jul 30.

2.

Highly accelerated acquisition and homogeneous image reconstruction with rotating RF coil array at 7T-A phantom based study.

Li M, Zuo Z, Jin J, Xue R, Trakic A, Weber E, Liu F, Crozier S.

J Magn Reson. 2014 Mar;240:102-12. doi: 10.1016/j.jmr.2013.11.002. Epub 2013 Nov 15.

PMID:
24365100
3.

Design and comparison of two eight-channel transmit/receive radiofrequency arrays for in vivo rodent imaging on a 7 T human whole-body MRI system.

Orzada S, Maderwald S, Göricke SL, Parohl N, Ladd SC, Ladd ME, Quick HH.

Med Phys. 2010 May;37(5):2225-32.

PMID:
20527556
4.

An inverse method to design RF coil arrays optimized for SENSE imaging.

Muftuler LT, Chen G, Nalcioglu O.

Phys Med Biol. 2006 Dec 21;51(24):6457-69. Epub 2006 Dec 1.

PMID:
17148829
5.

A 16-channel receive, forced current excitation dual-transmit coil for breast imaging at 7T.

By S, Rispoli JV, Cheshkov S, Dimitrov I, Cui J, Seiler S, Goudreau S, Malloy C, Wright SM, McDougall MP.

PLoS One. 2014 Nov 24;9(11):e113969. doi: 10.1371/journal.pone.0113969. eCollection 2014.

6.

Novel RF coil geometry for lower extremity imaging.

Brown R, Mareyam A, Reid E, Wang Y.

Magn Reson Med. 2004 Mar;51(3):635-9.

7.

7T transmit/receive arrays using ICE decoupling for human head MR imaging.

Yan X, Zhang X, Feng B, Ma C, Wei L, Xue R.

IEEE Trans Med Imaging. 2014 Sep;33(9):1781-7. doi: 10.1109/TMI.2014.2313879. Epub 2014 Apr 1.

PMID:
24710826
8.

Comparison of volume, four- and eight-channel head coils using standard and parallel imaging.

Gizewski ER, Maderwald S, Wanke I, Goehde S, Forsting M, Ladd ME.

Eur Radiol. 2005 Aug;15(8):1555-62. Epub 2005 Apr 23.

PMID:
15856247
9.

MREIT experiments with 200 µA injected currents: a feasibility study using two reconstruction algorithms, SMM and harmonic B(Z).

Arpinar VE, Hamamura MJ, Degirmenci E, Muftuler LT.

Phys Med Biol. 2012 Jul 7;57(13):4245-61. doi: 10.1088/0031-9155/57/13/4245. Epub 2012 Jun 8.

10.

Comparison of three commercially available radio frequency coils for human brain imaging at 3 Tesla.

Mekle R, van der Zwaag W, Joosten A, Gruetter R.

MAGMA. 2008 Mar;21(1-2):53-61. doi: 10.1007/s10334-007-0100-4. Epub 2008 Jan 10.

PMID:
18193311
11.

Electrical conductivity imaging by magnetic resonance electrical impedance tomography (MREIT).

Oh SH, Han JY, Lee SY, Cho MH, Lee BI, Woo EJ.

Magn Reson Med. 2003 Oct;50(4):875-8.

12.

Optimization of magnetic flux density for fast MREIT conductivity imaging using multi-echo interleaved partial fourier acquisitions.

Chauhan M, Jeong WC, Kim HJ, Kwon OI, Woo EJ.

Biomed Eng Online. 2013 Aug 27;12:82. doi: 10.1186/1475-925X-12-82.

13.

High-resolution magnetic resonance angiography of the lower extremities with a dedicated 36-element matrix coil at 3 Tesla.

Kramer H, Michaely HJ, Matschl V, Schmitt P, Reiser MF, Schoenberg SO.

Invest Radiol. 2007 Jun;42(6):477-83.

PMID:
17507821
14.

Special designed RF-antenna with integrated non-invasive carbon electrodes for simultaneous magnetic resonance imaging and electroencephalography acquisition at 7T.

Van Audekerkea J, Peeters R, Verhoye M, Sijbers J, Van der Linden A.

Magn Reson Imaging. 2000 Sep;18(7):887-91.

PMID:
11027884
15.

In vivo sensitivity estimation and imaging acceleration with rotating RF coil arrays at 7 Tesla.

Li M, Jin J, Zuo Z, Liu F, Trakic A, Weber E, Zhuo Y, Xue R, Crozier S.

J Magn Reson. 2015 Mar;252:29-40. doi: 10.1016/j.jmr.2014.12.004. Epub 2014 Dec 26.

PMID:
25635352
16.

Ophthalmic magnetic resonance imaging at 7 T using a 6-channel transceiver radiofrequency coil array in healthy subjects and patients with intraocular masses.

Graessl A, Muhle M, Schwerter M, Rieger J, Oezerdem C, Santoro D, Lysiak D, Winter L, Hezel F, Waiczies S, Guthoff RF, Falke K, Hosten N, Hadlich S, Krueger PC, Langner S, Stachs O, Niendorf T.

Invest Radiol. 2014 May;49(5):260-70. doi: 10.1097/RLI.0000000000000049.

PMID:
24651662
17.

A high-throughput eight-channel probe head for murine MRI at 9.4 T.

Lanz T, Müller M, Barnes H, Neubauer S, Schneider JE.

Magn Reson Med. 2010 Jul;64(1):80-7. doi: 10.1002/mrm.22414.

18.

Basic considerations on the impact of the coil array on the performance of Transmit SENSE.

Katscher U, Röhrs J, Börnert P.

MAGMA. 2005 May;18(2):81-8. Epub 2005 Feb 11.

PMID:
15711852
19.

Harmonic decomposition in PDE-based denoising technique for magnetic resonance electrical impedance tomography.

Lee BI, Lee SH, Kim TS, Kwon O, Woo EJ, Seo JK.

IEEE Trans Biomed Eng. 2005 Nov;52(11):1912-20.

PMID:
16285395
20.

Sensitivity of an eight-element phased array coil in 3 Tesla MR imaging: a basic analysis.

Hiratsuka Y, Miki H, Kikuchi K, Kiriyama I, Mochizuki T, Takahashi S, Sadamoto K.

Magn Reson Med Sci. 2007;6(3):177-81.

Supplemental Content

Support Center