Format
Sort by
Items per page

Send to

Choose Destination

Links from PubMed

Items: 1 to 20 of 119

1.

Experiments and observations regarding the mechanisms of glass removal in magnetorheological finishing.

Shorey AB, Jacobs SD, Kordonski WI, Gans RF.

Appl Opt. 2001 Jan 1;40(1):20-33.

PMID:
18356970
2.

Removal rate model for magnetorheological finishing of glass.

Degroote JE, Marino AE, Wilson JP, Bishop AL, Lambropoulos JC, Jacobs SD.

Appl Opt. 2007 Nov 10;46(32):7927-41.

PMID:
17994145
3.

Zirconia-coated carbonyl-iron-particle-based magnetorheological fluid for polishing optical glasses and ceramics.

Shafrir SN, Romanofsky HJ, Skarlinski M, Wang M, Miao C, Salzman S, Chartier T, Mici J, Lambropoulos JC, Shen R, Yang H, Jacobs SD.

Appl Opt. 2009 Dec 10;48(35):6797-810. doi: 10.1364/AO.48.006797.

PMID:
20011021
4.

Process parameter effects on material removal in magnetorheological finishing of borosilicate glass.

Miao C, Lambropoulos JC, Jacobs SD.

Appl Opt. 2010 Apr 1;49(10):1951-63. doi: 10.1364/AO.49.001951.

PMID:
20357881
5.

Minimizing artifact formation in magnetorheological finishing of chemical vapor deposition ZnS flats.

Kozhinova IA, Romanofsky HJ, Maltsev A, Jacobs SD, Kordonski WI, Gorodkin SR.

Appl Opt. 2005 Aug 1;44(22):4671-7.

PMID:
16075880
6.

Nanoindentation hardness of particles used in magnetorheological finishing (MRF).

Shorey AB, Kwong KM, Johnson KM, Jacobs SD.

Appl Opt. 2000 Oct 1;39(28):5194-204.

PMID:
18354516
7.

Acidic magnetorheological finishing of infrared polycrystalline materials.

Salzman S, Romanofsky HJ, West G, Marshall KL, Jacobs SD, Lambropoulos JC.

Appl Opt. 2016 Oct 20;55(30):8448-8456. doi: 10.1364/AO.55.008448.

PMID:
27828155
8.

Shear stress in magnetorheological finishing for glasses.

Miao C, Shafrir SN, Lambropoulos JC, Mici J, Jacobs SD.

Appl Opt. 2009 May 1;48(13):2585-94.

PMID:
19412219
9.

The Magnetorheological Finishing (MRF) of Potassium Dihydrogen Phosphate (KDP) Crystal with Fe3O4 Nanoparticles.

Ji F, Xu M, Wang C, Li X, Gao W, Zhang Y, Wang B, Tang G, Yue X.

Nanoscale Res Lett. 2016 Dec;11(1):79. doi: 10.1186/s11671-016-1301-4. Epub 2016 Feb 9.

10.

Magnetic field effects on shear and normal stresses in magnetorheological finishing.

Lambropoulos JC, Miao C, Jacobs SD.

Opt Express. 2010 Sep 13;18(19):19713-23. doi: 10.1364/OE.18.019713.

PMID:
20940866
11.

Research of polishing process to control the iron contamination on the magnetorheological finished KDP crystal surface.

Chen S, Li S, Peng X, Hu H, Tie G.

Appl Opt. 2015 Feb 20;54(6):1478-84. doi: 10.1364/AO.54.001478.

PMID:
25968216
12.

Rapid fabrication of a silicon modification layer on silicon carbide substrate.

Bai Y, Li L, Xue D, Zhang X.

Appl Opt. 2016 Aug 1;55(22):5814-20. doi: 10.1364/AO.55.005814.

PMID:
27505358
13.

Calibration and prediction of removal function in magnetorheological finishing.

Dai Y, Song C, Peng X, Shi F.

Appl Opt. 2010 Jan 20;49(3):298-306. doi: 10.1364/AO.49.000298.

PMID:
20090792
14.

Magnetorheological finishing of chemical-vapor deposited zinc sulfide via chemically and mechanically modified fluids.

Salzman S, Romanofsky HJ, Giannechini LJ, Jacobs SD, Lambropoulos JC.

Appl Opt. 2016 Feb 20;55(6):1481-9. doi: 10.1364/AO.55.001481.

PMID:
26906603
15.

Influence law of structural characteristics on the surface roughness of a magnetorheological-finished KDP crystal.

Chen S, Li S, Hu H, Li Q, Tie G.

Appl Opt. 2014 Nov 1;53(31):7215-23. doi: 10.1364/AO.53.007215.

PMID:
25402879
16.

Effects of temperature on the removal efficiency of KDP crystal during the process of magnetorheological water-dissolution polishing.

Zhang Y, Dai Y, Tie G, Hu H.

Appl Opt. 2016 Oct 10;55(29):8308-8315. doi: 10.1364/AO.55.008308.

PMID:
27828080
17.
18.
19.

Research on reducing the edge effect in magnetorheological finishing.

Hu H, Dai Y, Peng X, Wang J.

Appl Opt. 2011 Mar 20;50(9):1220-6. doi: 10.1364/AO.50.001220.

PMID:
21460993
20.

Effect of finishing technique on the microleakage and surface texture of resin-modified glass ionomer restorative materials.

Wilder AD Jr, Swift EJ Jr, May KN Jr, Thompson JY, McDougal RA.

J Dent. 2000 Jul;28(5):367-73.

PMID:
10785304

Supplemental Content

Support Center