Format
Sort by
Items per page

Send to

Choose Destination

Links from PubMed

Items: 1 to 20 of 136

1.

A sub-microwatt piezo-floating-gate sensor for long-term fatigue monitoring in biomechanical implants.

Lajnef N, Chakrabartty S, Elvin N, Elvin A.

Conf Proc IEEE Eng Med Biol Soc. 2006;1:5936-9.

PMID:
17946349
2.

A piezo-powered floating-gate sensor array for long-term fatigue monitoring in biomechanical implants.

Lajnef N, Elvin NG, Chakrabartty S.

IEEE Trans Biomed Circuits Syst. 2008 Sep;2(3):164-72. doi: 10.1109/TBCAS.2008.2001473.

PMID:
23852966
3.

An ultra-linear piezo-floating-gate strain-gauge for self-powered measurement of quasi-static-strain.

Sarkar P, Huang C, Chakrabartty S.

IEEE Trans Biomed Circuits Syst. 2013 Aug;7(4):437-50. doi: 10.1109/TBCAS.2012.2220764.

PMID:
23893203
4.

N-Channel field-effect transistors with floating gates for extracellular recordings.

Meyburg S, Goryll M, Moers J, Ingebrandt S, Böcker-Meffert S, Lüth H, Offenhäusser A.

Biosens Bioelectron. 2006 Jan 15;21(7):1037-44. Epub 2005 Jul 18.

PMID:
16029948
5.

Design and fabrication of a largely deformable sensorized polymer actuator.

Ryu J, Park J, Kim B, Park JO.

Biosens Bioelectron. 2005 Nov 15;21(5):822-6.

PMID:
16242623
6.

An FET-type charge sensor for highly sensitive detection of DNA sequence.

Kim DS, Jeong YT, Park HJ, Shin JK, Choi P, Lee JH, Lim G.

Biosens Bioelectron. 2004 Jul 30;20(1):69-74.

PMID:
15142578
7.

Electrolyte pulse current measurements by CvMOS with microsecond and thermal voltage resolution.

Jacquot BC, Muñoz N, Kan EC.

Conf Proc IEEE Eng Med Biol Soc. 2006;1:1846-9.

PMID:
17945675
8.

A low-voltage wide-input CMOS comparator for sensor application using back-gate technique.

Hung YC, Liu BD.

Biosens Bioelectron. 2004 Jul 30;20(1):53-9.

PMID:
15142576
9.

Direct protein detection with a nano-interdigitated array gate MOSFET.

Tang X, Jonas AM, Nysten B, Demoustier-Champagne S, Blondeau F, Prévot PP, Pampin R, Godfroid E, Iñiguez B, Colinge JP, Raskin JP, Flandre D, Bayot V.

Biosens Bioelectron. 2009 Aug 15;24(12):3531-7. doi: 10.1016/j.bios.2009.05.012. Epub 2009 May 18.

PMID:
19501500
10.

Broadband electrical impedance matching for piezoelectric ultrasound transducers.

Huang H, Paramo D.

IEEE Trans Ultrason Ferroelectr Freq Control. 2011 Dec;58(12):2699-707. doi: 10.1109/TUFFC.2011.2132.

PMID:
23443705
11.

Identifying the mechanism of biosensing with carbon nanotube transistors.

Heller I, Janssens AM, Männik J, Minot ED, Lemay SG, Dekker C.

Nano Lett. 2008 Feb;8(2):591-5. Epub 2007 Dec 28.

PMID:
18162002
12.

A PVDF transducer for low-frequency acceleration measurements.

Daku BL, Mohamed EM, Prugger AF.

ISA Trans. 2004 Jul;43(3):319-28.

PMID:
15272789
13.

Depletion type floating gate p-channel MOS transistor for recording action potentials generated by cultured neurons.

Cohen A, Spira ME, Yitshaik S, Borghs G, Shwartzglass O, Shappir J.

Biosens Bioelectron. 2004 Jul 15;19(12):1703-9.

PMID:
15142605
14.

A wide range charge-balancing circuit using floating-gate transistors.

Hu J, Gordon C.

Conf Proc IEEE Eng Med Biol Soc. 2007;2007:5696-9.

PMID:
18003305
15.

Label-free DNA sensor based on organic thin film transistors.

Yan F, Mok SM, Yu J, Chan HL, Yang M.

Biosens Bioelectron. 2009 Jan 1;24(5):1241-5. doi: 10.1016/j.bios.2008.07.030. Epub 2008 Jul 26.

PMID:
18771910
16.

High frequency piezoelectric MEMS ultrasound transducers.

Mina IG, Kim H, Kim I, Park SK, Choi K, Jackson TN, Tutwiler RL, Trolier-McKinstry S.

IEEE Trans Ultrason Ferroelectr Freq Control. 2007 Dec;54(12):2422-30. doi: 10.1109/TUFFC.2007.555.

PMID:
18276533
17.

Novel neuromorphic CMOS device array for biochemical charge sensing.

Pandey S, Daryanani M, Chen B, Tao C.

Conf Proc IEEE Eng Med Biol Soc. 2008;2008:2291-4. doi: 10.1109/IEMBS.2008.4649655.

PMID:
19163158
18.

Very low-noise ENG amplifier system using CMOS technology.

Rieger R, Schuettler M, Pal D, Clarke C, Langlois P, Taylor J, Donaldson N.

IEEE Trans Neural Syst Rehabil Eng. 2006 Dec;14(4):427-37.

PMID:
17190035
19.

Micromechanical mass sensors for biomolecular detection in a physiological environment.

Braun T, Barwich V, Ghatkesar MK, Bredekamp AH, Gerber C, Hegner M, Lang HP.

Phys Rev E Stat Nonlin Soft Matter Phys. 2005 Sep;72(3 Pt 1):031907. Epub 2005 Sep 14.

PMID:
16241482
20.

TranSIESTA: a spice for molecular electronics.

Stokbro K, Taylor J, Brandbyge M, Ordejón P.

Ann N Y Acad Sci. 2003 Dec;1006:212-26.

PMID:
14976020

Supplemental Content

Support Center