Format
Sort by
Items per page

Send to

Choose Destination

Links from PubMed

Items: 1 to 20 of 138

1.

Double-lumen tube position should be confirmed by fiberoptic bronchoscopy.

Cohen E.

Curr Opin Anaesthesiol. 2004 Feb;17(1):1-6.

PMID:
17021522
2.

Fiberoptic bronchoscopy need not be a routine part of double-lumen tube placement.

Brodsky JB.

Curr Opin Anaesthesiol. 2004 Feb;17(1):7-11.

PMID:
17021523
3.

[Influence of the position of double-lumen endobronchial tube on the efficacy of lung separation and ventilation].

Hou HW, Ouyang BY.

Nan Fang Yi Ke Da Xue Xue Bao. 2006 May;26(5):576-8. Chinese.

4.

Role of fiberoptic bronchoscopy in conjunction with the use of double-lumen tubes for thoracic anesthesia: a prospective study.

Klein U, Karzai W, Bloos F, Wohlfarth M, Gottschall R, Fritz H, Gugel M, Seifert A.

Anesthesiology. 1998 Feb;88(2):346-50.

PMID:
9477054
6.

Update on tracheobronchial anatomy and flexible fiberoptic bronchoscopy in thoracic anesthesia.

Campos JH.

Curr Opin Anaesthesiol. 2009 Feb;22(1):4-10. doi: 10.1097/ACO.0b013e32831a43ab. Review.

PMID:
19295287
7.

Use of a video fiberoptic bronchoscope to assist double-lumen endobronchial tube intubation in a patient with a difficult airway.

Chen KY, Lin SK, Hsiao CL, Hsu WT, Tsao SL.

Acta Anaesthesiol Taiwan. 2011 Mar;49(1):26-8. doi: 10.1016/j.aat.2011.02.002. Epub 2011 Mar 17.

8.

Inflation of the distal cuff by saline reduces the incidence of malposition of the bronchial tube during lung separation in patients receiving nitrous oxide.

Suzuki M, Haraguchi S, Kitamura A, Shimada Y, Sakamoto A.

J Cardiothorac Vasc Anesth. 2007 Dec;21(6):838-42. Epub 2007 Feb 22.

PMID:
18068062
9.

Modified right-sided Broncho-Cath double lumen tube improves endobronchial positioning: a randomized study.

Bussières JS, Lacasse Y, Côté D, Beauvais M, St-Onge S, Lemieux J, Soucy J.

Can J Anaesth. 2007 Apr;54(4):276-82.

PMID:
17400979
10.

Fiberoptic bronchoscopic positioning of double-lumen tubes.

Slinger PD.

J Cardiothorac Anesth. 1989 Aug;3(4):486-96. Review.

PMID:
2520925
11.

Methods of lung separation.

Cohen E.

Minerva Anestesiol. 2004 May;70(5):313-8.

12.

Methods of lung separation.

Cohen E.

Curr Opin Anaesthesiol. 2002 Feb;15(1):69-78.

PMID:
17019187
13.

[Comparison of the double-lumen endotracheal tube and the Arndt bronchial blocker used by inexperienced anesthesiologists in right- and left-sided thoracic surgery].

Vilà E, García Guasch R, Ibáñez C, Rodríguez M, Martínez L, López de Castro P.

Rev Esp Anestesiol Reanim. 2007 Dec;54(10):602-7. Spanish.

PMID:
18200995
14.

The use of fiberoptic endoscopy in anesthesia.

Lee AC, Wu CL, Feins RH, Ward DS.

Chest Surg Clin N Am. 1996 May;6(2):329-47. Review.

PMID:
8724282
15.
16.

Incidence of malposition of polyvinylchloride and red rubber left-sided double-lumen tubes and clinical sequelae.

Cohen E, Neustein SM, Goldofsky S, Camunas JL.

J Cardiothorac Vasc Anesth. 1995 Apr;9(2):122-7.

PMID:
7780066
17.

[Correct placement of left-sided double lumen endotracheal tubes: a simple verification technique].

Zango BA, Morales SP, Raimundo MG, Pinillos JL, Paulino AM, Nácher JB.

Rev Esp Anestesiol Reanim. 2008 May;55(5):277-81. Spanish.

PMID:
18661686
18.

[Fiber bronchoscopy as an aid in placing and monitoring double lumen tubes in thoracic anesthesia].

Schottke-Hennings H, Klippe HJ, Schmieding B.

Anasth Intensivther Notfallmed. 1989 Dec;24(6):327-33. German.

PMID:
2618989
19.

[Connector for double-lumen tubes in thoracic surgery interventions].

Klein U, Knebel F, Gottschall R.

Anasthesiol Intensivmed Notfallmed Schmerzther. 1993 Nov;28(7):467-9. German.

PMID:
8297957
20.

Double-lumen tube placement using a retractable carinal hook: a preliminary report.

Al-Metwalli RR, Mowafi HA, Ismail SA.

Anesth Analg. 2009 Aug;109(2):447-50. doi: 10.1213/ane.0b013e3181ac6d78.

PMID:
19608816

Supplemental Content

Support Center