Format
Sort by
Items per page

Send to

Choose Destination

Links from PubMed

Items: 1 to 20 of 80

1.

Time course EPI of human brain function during task activation.

Bandettini PA, Wong EC, Hinks RS, Tikofsky RS, Hyde JS.

Magn Reson Med. 1992 Jun;25(2):390-7.

PMID:
1614324
2.

Spin-echo and gradient-echo EPI of human brain activation using BOLD contrast: a comparative study at 1.5 T.

Bandettini PA, Wong EC, Jesmanowicz A, Hinks RS, Hyde JS.

NMR Biomed. 1994 Mar;7(1-2):12-20.

PMID:
8068520
3.

Dynamic magnetic resonance imaging of human brain activity during primary sensory stimulation.

Kwong KK, Belliveau JW, Chesler DA, Goldberg IE, Weisskoff RM, Poncelet BP, Kennedy DN, Hoppel BE, Cohen MS, Turner R, et al.

Proc Natl Acad Sci U S A. 1992 Jun 15;89(12):5675-9.

4.

Simultaneous recording of cerebral blood oxygenation changes during human brain activation by magnetic resonance imaging and near-infrared spectroscopy.

Kleinschmidt A, Obrig H, Requardt M, Merboldt KD, Dirnagl U, Villringer A, Frahm J.

J Cereb Blood Flow Metab. 1996 Sep;16(5):817-26.

PMID:
8784226
5.

Inflow versus deoxyhemoglobin effects in BOLD functional MRI using gradient echoes at 1.5 T.

Duyn JH, Moonen CT, van Yperen GH, de Boer RW, Luyten PR.

NMR Biomed. 1994 Mar;7(1-2):83-8.

PMID:
8068530
6.

Assessment of spatial BOLD sensitivity variations in fMRI using gradient-echo field maps.

Mannfolk P, Wirestam R, Nilsson M, van Westen D, Ståhlberg F, Olsrud J.

Magn Reson Imaging. 2010 Sep;28(7):947-56. doi: 10.1016/j.mri.2010.05.003. Epub 2010 Jun 22. Erratum in: Magn Reson Imaging. 2011 May;29(4):586.

PMID:
20573463
7.

Brain or vein--oxygenation or flow? On signal physiology in functional MRI of human brain activation.

Frahm J, Merboldt KD, Hänicke W, Kleinschmidt A, Boecker H.

NMR Biomed. 1994 Mar;7(1-2):45-53.

PMID:
8068525
8.

Functional connectivity in the motor cortex of resting human brain using echo-planar MRI.

Biswal B, Yetkin FZ, Haughton VM, Hyde JS.

Magn Reson Med. 1995 Oct;34(4):537-41.

PMID:
8524021
9.

Functional magnetic resonance imaging of the human brain: data acquisition and analysis.

Turner R, Howseman A, Rees GE, Josephs O, Friston K.

Exp Brain Res. 1998 Nov;123(1-2):5-12. Review.

PMID:
9835386
10.
11.

Brain magnetic resonance imaging with contrast dependent on blood oxygenation.

Ogawa S, Lee TM, Kay AR, Tank DW.

Proc Natl Acad Sci U S A. 1990 Dec;87(24):9868-72.

12.

Echo-planar MR imaging of human brain oxygenation changes.

Stehling MK, Schmitt F, Ladebeck R.

J Magn Reson Imaging. 1993 May-Jun;3(3):471-4.

PMID:
8324305
13.

No increase of the blood oxygenation level-dependent functional magnetic resonance imaging signal with higher field strength: implications for brain activation studies.

Seehafer JU, Kalthoff D, Farr TD, Wiedermann D, Hoehn M.

J Neurosci. 2010 Apr 14;30(15):5234-41. doi: 10.1523/JNEUROSCI.0844-10.2010.

14.

Comparison of blood-oxygen-level-dependent functional magnetic resonance imaging and near-infrared spectroscopy recording during functional brain activation in patients with stroke and brain tumors.

Sakatani K, Murata Y, Fujiwara N, Hoshino T, Nakamura S, Kano T, Katayama Y.

J Biomed Opt. 2007 Nov-Dec;12(6):062110. doi: 10.1117/1.2823036. Review.

PMID:
18163813
15.

Comparison of functional MR-venography and EPI-BOLD fMRI at 1.5 T.

Baudendistel KT, Reichenbach JR, Metzner R, Schroeder J, Schad LR.

Magn Reson Imaging. 1998 Oct;16(8):989-91.

PMID:
9814782
16.

Investigating the benefits of multi-echo EPI for fMRI at 7 T.

Poser BA, Norris DG.

Neuroimage. 2009 May 1;45(4):1162-72. doi: 10.1016/j.neuroimage.2009.01.007. Epub 2009 Jan 21.

PMID:
19349231
17.

A quantitative comparison of simultaneous BOLD fMRI and NIRS recordings during functional brain activation.

Strangman G, Culver JP, Thompson JH, Boas DA.

Neuroimage. 2002 Oct;17(2):719-31.

PMID:
12377147
18.

EPI imaging of global increase of brain MR signal with breath-hold preceded by breathing O2.

Kwong KK, Wanke I, Donahue KM, Davis TL, Rosen BR.

Magn Reson Med. 1995 Mar;33(3):448-52.

PMID:
7760716
19.

Functional MRI of the human brain with GRASE-based BOLD contrast.

Jovicich J, Norris DG.

Magn Reson Med. 1999 May;41(5):871-6.

20.

Whole brain, high resolution multiband spin-echo EPI fMRI at 7 T: a comparison with gradient-echo EPI using a color-word Stroop task.

Boyacioğlu R, Schulz J, Müller NC, Koopmans PJ, Barth M, Norris DG.

Neuroimage. 2014 Aug 15;97:142-50. doi: 10.1016/j.neuroimage.2014.04.011. Epub 2014 Apr 13.

PMID:
24736172

Supplemental Content

Support Center