Format
Sort by
Items per page

Send to

Choose Destination

Links from PubMed

Items: 1 to 20 of 122

1.

Microbiological evaluation of endodontic files after cleaning and steam sterilization procedures.

Van Eldik DA, Zilm PS, Rogers AH, Marin PD.

Aust Dent J. 2004 Sep;49(3):122-7.

2.

A SEM evaluation of debris removal from endodontic files after cleaning and steam sterilization procedures.

Van Eldik DA, Zilm PS, Rogers AH, Marin PD.

Aust Dent J. 2004 Sep;49(3):128-35.

3.

Cleaning of used rotary nickel-titanium files in an ultrasonic bath by locally intensified acoustic cavitation.

Bryson LM, Fernandez Rivas D, Boutsioukis C.

Int Endod J. 2018 Apr;51(4):457-468. doi: 10.1111/iej.12866. Epub 2017 Nov 1.

PMID:
29023781
5.

The effect of pre-soaking and time in the ultrasonic cleaner on the cleanliness of sterilized endodontic files.

Aasim SA, Mellor AC, Qualtrough AJ.

Int Endod J. 2006 Feb;39(2):143-9.

PMID:
16454795
6.

Cleaning endodontic files in a washer disinfector.

Assaf M, Mellor AC, Qualtrough AJ.

Br Dent J. 2008 May 24;204(10):E17; discussion 562-3. doi: 10.1038/sj.bdj.2008.411. Epub 2008 May 23.

PMID:
18493255
7.

A cleaning protocol for rotary nickel-titanium endodontic instruments.

Parashos P, Linsuwanont P, Messer HH.

Aust Dent J. 2004 Mar;49(1):20-7.

8.

Cleaning of endodontic files, Part I: The effect of bioburden on the sterilization of endodontic files.

Johnson MA, Primack PD, Loushine RJ, Craft DW.

J Endod. 1997 Jan;23(1):32-4.

PMID:
9594742
9.

Evaluation of biological debris on endodontic instruments after cleaning and sterilization procedures.

Popovic J, Gasic J, Zivkovic S, Petrovic A, Radicevic G.

Int Endod J. 2010 Apr;43(4):336-41. doi: 10.1111/j.1365-2591.2010.01686.x.

PMID:
20487454
10.

Effective cleaning protocols for rotary niclkel-titanium files.

Parashos P, Linsuwanont P, Messer HH.

Aust Endod J. 2003 Apr;29(1):23-4.

PMID:
12772968
11.

Comparison of an ultrasonic cleaner and a washer disinfector in the cleaning of endodontic files.

Perakaki K, Mellor AC, Qualtrough AJ.

J Hosp Infect. 2007 Dec;67(4):355-9. Epub 2007 Nov 19.

PMID:
18023926
12.

Effect of three nickel-titanium rotary file techniques on infected root dentin reduction.

Chuste-Guillot MP, Badet C, Peli JF, Perez F.

Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2006 Aug;102(2):254-8. Epub 2006 Apr 21.

PMID:
16876071
13.

Torsional properties of stainless-steel and nickel-titanium files after multiple autoclave sterilizations.

Hilt BR, Cunningham CJ, Shen C, Richards N.

J Endod. 2000 Feb;26(2):76-80.

PMID:
11194376
14.

Cleaning of rotary nickel-titanium endodontic instruments.

Linsuwanont P, Parashos P, Messer HH.

Int Endod J. 2004 Jan;37(1):19-28.

PMID:
14718053
15.

The sterilization of endodontic hand files.

Hurtt CA, Rossman LE.

J Endod. 1996 Jun;22(6):321-2.

PMID:
8934994
16.

Comparison of autoclaving effects on torsional deformation and fracture resistance of three innovative endodontic file systems.

Casper RB, Roberts HW, Roberts MD, Himel VT, Bergeron BE.

J Endod. 2011 Nov;37(11):1572-5. doi: 10.1016/j.joen.2011.07.008. Epub 2011 Sep 9.

PMID:
22000466
17.
18.

The effectiveness of three instrumentation techniques on the elimination of Enterococcus faecalis from a root canal: an in vitro study.

Colak M, Evcil S, Bayindir YZ, Yigit N.

J Contemp Dent Pract. 2005 Feb 15;6(1):94-106.

PMID:
15719081
19.

Histologic analysis of the cleaning capacity of mechanical endodontic instruments activated by the ENDOflash system.

Fariniuk LF, Baratto-Filho F, da Cruz-Filho AM, de Sousa-Neto MD.

J Endod. 2003 Oct;29(10):651-3.

PMID:
14606788
20.

Changes in root canal morphology in simulated curved canals over-instrumented with a variety of stainless steel and nickel titanium files.

Lam TV, Lewis DJ, Atkins DR, Macfarlane RH, Clarkson RM, Whitehead MG, Brockhurst PJ, Moule AJ.

Aust Dent J. 1999 Mar;44(1):12-9.

Supplemental Content

Support Center