Format
Sort by
Items per page

Send to

Choose Destination

Links from PubMed

Items: 1 to 20 of 510

1.

Forward-viewing CMUT arrays for medical imaging.

Demirci U, Ergun AS, Oralkan O, Karaman M, Khuri-Yakub BT.

IEEE Trans Ultrason Ferroelectr Freq Control. 2004 Jul;51(7):887-95.

PMID:
15301009
2.

Integration of 2D CMUT arrays with front-end electronics for volumetric ultrasound imaging.

Wygant IO, Zhuang X, Yeh DT, Oralkan O, Sanli Ergun A, Karaman M, Khuri-Yakub BT.

IEEE Trans Ultrason Ferroelectr Freq Control. 2008 Feb;55(2):327-42. doi: 10.1109/TUFFC.2008.652.

PMID:
18334340
3.

Annular-ring CMUT arrays for forward-looking IVUS: transducer characterization and imaging.

Degertekin FL, Guldiken RO, Karaman M.

IEEE Trans Ultrason Ferroelectr Freq Control. 2006 Feb;53(2):474-82.

PMID:
16529123
4.

Design, fabrication and characterization of a capacitive micromachined ultrasonic probe for medical imaging.

Caliano G, Carotenuto R, Cianci E, Foglietti V, Caronti A, Iula A, Pappalardo M.

IEEE Trans Ultrason Ferroelectr Freq Control. 2005 Dec;52(12):2259-69.

PMID:
16463491
5.

3-D ultrasound imaging using a forward-looking CMUT ring array for intravascular/intracardiac applications.

Yeh DT, Oralkan O, Wygant IO, O'Donnell M, Khuri-Yakub BT.

IEEE Trans Ultrason Ferroelectr Freq Control. 2006 Jun;53(6):1202-11.

PMID:
16846153
6.

Volumetric ultrasound imaging using 2-D CMUT arrays.

Oralkan O, Ergun AS, Cheng CH, Johnson JA, Karaman M, Lee TH, Khuri-Yakub BT.

IEEE Trans Ultrason Ferroelectr Freq Control. 2003 Nov;50(11):1581-94.

PMID:
14682642
7.

Exploitation of capacitive micromachined transducers for nonlinear ultrasound imaging.

Novell A, Legros M, Felix N, Bouakaz A.

IEEE Trans Ultrason Ferroelectr Freq Control. 2009 Dec;56(12):2733-43. doi: 10.1109/TUFFC.2009.1364.

PMID:
20040410
8.

Wafer-bonded 2-D CMUT arrays incorporating through-wafer trench-isolated interconnects with a supporting frame.

Zhuang X, Wygant IO, Lin DS, Kupnik M, Oralkan O, Khuri-Yakub BT.

IEEE Trans Ultrason Ferroelectr Freq Control. 2009 Jan;56(1):182-92. doi: 10.1109/TUFFC.2009.1018.

PMID:
19213645
9.

Design of a front-end integrated circuit for 3D acoustic imaging using 2D CMUT arrays.

Ciçek I, Bozkurt A, Karaman M.

IEEE Trans Ultrason Ferroelectr Freq Control. 2005 Dec;52(12):2235-41.

PMID:
16463489
10.

Optimization of the gain-bandwidth product of capacitive micromachined ultrasonic transducers.

Olcum S, Senlik MN, Atalar A.

IEEE Trans Ultrason Ferroelectr Freq Control. 2005 Dec;52(12):2211-9.

PMID:
16463487
11.

CMUT array modeling through free acoustic CMUT modes and analysis of the fluid CMUT interface through Fourier transform methods.

Rønnekleiv A.

IEEE Trans Ultrason Ferroelectr Freq Control. 2005 Dec;52(12):2173-84.

PMID:
16463484
12.

An integrated circuit with transmit beamforming flip-chip bonded to a 2-D CMUT array for 3-D ultrasound imaging.

Wygant IO, Jamal NS, Lee HJ, Nikoozadeh A, Oralkan O, Karaman M, Khuri-Yakub BT.

IEEE Trans Ultrason Ferroelectr Freq Control. 2009 Oct;56(10):2145-56. doi: 10.1109/TUFFC.2009.1297.

PMID:
19942502
13.

Design and fabrication of annular arrays for high-frequency ultrasound.

Brown JA, Démoré CE, Lockwood GR.

IEEE Trans Ultrason Ferroelectr Freq Control. 2004 Aug;51(8):1010-7.

PMID:
15344406
14.

CMUTS with dual-electrode structure for improved transmit and receive performance.

Guldiken RO, McLean J, Degertekin FL.

IEEE Trans Ultrason Ferroelectr Freq Control. 2006 Feb;53(2):483-91.

PMID:
16529124
15.

Capacitive micromachined ultrasonic transducers: next-generation arrays for acoustic imaging?

Oralkan O, Ergun AS, Johnson JA, Karaman M, Demirci U, Kaviani K, Lee TH, Khuri-Yakub BT.

IEEE Trans Ultrason Ferroelectr Freq Control. 2002 Nov;49(11):1596-610.

PMID:
12484483
16.

Three-dimensional photoacoustic imaging using a two-dimensional CMUT array.

Vaithilingam S, Ma TJ, Furukawa Y, Wygant IO, Zhuang X, De La Zerda A, Oralkan O, Kamaya A, Gambhir SS, Jeffrey RB Jr, Khuri-Yakub BT.

IEEE Trans Ultrason Ferroelectr Freq Control. 2009 Nov;56(11):2411-9. doi: 10.1109/TUFFc.2009.1329.

PMID:
19942528
17.

Dynamic analysis of capacitive micromachined ultrasonic transducers.

Bayram B, Yaralioglu GG, Kupnik M, Ergun AS, Oralkan O, Nikoozadeh A, Khuri-Yakub BT.

IEEE Trans Ultrason Ferroelectr Freq Control. 2005 Dec;52(12):2270-5.

PMID:
16463492
18.

High-frequency ultrasound annular-array imaging. Part I: array design and fabrication.

Snook KA, Hu CH, Shrout TR, Shung KK.

IEEE Trans Ultrason Ferroelectr Freq Control. 2006 Feb;53(2):300-8.

PMID:
16529104
19.

Capacitive micromachined ultrasonic transducers: fabrication technology.

Ergun AS, Huang Y, Zhuang X, Oralkan O, Yaralioglu GG, Khuri-Yakub BT.

IEEE Trans Ultrason Ferroelectr Freq Control. 2005 Dec;52(12):2242-58.

PMID:
16463490
20.

Finite element modeling and experimental characterization of crosstalk in 1-D CMUT arrays.

Bayram B, Kupnik M, Yaralioglu GG, Oralkan O, Ergun AS, Lin DS, Wong SH, Khuri-Yakub BT.

IEEE Trans Ultrason Ferroelectr Freq Control. 2007 Feb;54(2):418-30.

PMID:
17328339

Supplemental Content

Support Center