1.

Comparison of residual geometric errors obtained for lung SBRT under static beams and VMAT techniques: Implications for PTV margins.

Vloet A, Li W, Giuliani M, Seco P, Silver L, Sun A, Bissonnette JP.

Phys Med. 2018 Aug;52:129-132. doi: 10.1016/j.ejmp.2018.07.009. Epub 2018 Jul 30. No abstract available.

PMID:
30139601
2.

Implementation of a voluntary deep inspiration breath hold technique (vDIBH) using BrainLab ExacTrac infrared optical tracking system.

Ippolito E, Fiore M, Di Donato A, Silipigni S, Rinaldi C, Cornacchione P, Infusino E, Di Venanzio C, Greco C, Trodella L, Ramella S, D'Angelillo RM.

PLoS One. 2018 May 10;13(5):e0195506. doi: 10.1371/journal.pone.0195506. eCollection 2018.

3.

Effects of megavoltage computed tomographic scan methodology on setup verification and adaptive dose calculation in helical TomoTherapy.

Zhu J, Bai T, Gu J, Sun Z, Wei Y, Li B, Yin Y.

Radiat Oncol. 2018 Apr 27;13(1):80. doi: 10.1186/s13014-018-0989-y.

4.

Analysis of which local set-up errors can be covered by a 5-mm margin for cone beam CT-guided radiotherapy for nasopharyngeal carcinoma.

Zhong R, Song Y, Yan Y, Wang X, Li S, Zhou J, Li X, Bai S.

Br J Radiol. 2018 Jul;91(1088):20160849. doi: 10.1259/bjr.20160849. Epub 2018 May 17.

PMID:
29688742
5.

Lower limb immobilization device induced small setup errors in the radiotherapy.

Lu Y, Ni X, Yu J, Ni X, Sun Z, Wang J, Sun S, Wang J.

Medicine (Baltimore). 2018 Apr;97(15):e0384. doi: 10.1097/MD.0000000000010384.

6.

Monitoring frequency of intra-fraction patient motion using the ExacTrac system for LINAC-based SRS treatments.

Lewis BC, Snyder WJ, Kim S, Kim T.

J Appl Clin Med Phys. 2018 May;19(3):58-63. doi: 10.1002/acm2.12279. Epub 2018 Mar 25.

7.

Assessment of dosimetric errors induced by deformable image registration methods in 4D pencil beam scanned proton treatment planning for liver tumours.

Ribeiro CO, Knopf A, Langendijk JA, Weber DC, Lomax AJ, Zhang Y.

Radiother Oncol. 2018 Jul;128(1):174-181. doi: 10.1016/j.radonc.2018.03.001. Epub 2018 Mar 20.

8.

Image guidance in clinical practice - Influence of positioning inaccuracy on the dose distribution for prostate cancer.

Bell K, Dzierma Y, Morlo M, Nüsken F, Licht N, Rübe C.

Phys Med. 2018 Feb;46:81-88. doi: 10.1016/j.ejmp.2018.01.015.

PMID:
29519414
9.

Comparison of MLC error sensitivity of various commercial devices for VMAT pre-treatment quality assurance.

Saito M, Sano N, Shibata Y, Kuriyama K, Komiyama T, Marino K, Aoki S, Ashizawa K, Yoshizawa K, Onishi H.

J Appl Clin Med Phys. 2018 May;19(3):87-93. doi: 10.1002/acm2.12288. Epub 2018 Mar 3.

10.

Setup errors in radiation therapy for thoracic tumor patients of different body mass index.

Zhao J, Zhang M, Zhai F, Wang H, Li X.

J Appl Clin Med Phys. 2018 May;19(3):27-31. doi: 10.1002/acm2.12270. Epub 2018 Mar 1.

11.

Under-reported dosimetry errors due to interplay effects during VMAT dose delivery in extreme hypofractionated stereotactic radiotherapy.

Gauer T, Sothmann T, Blanck O, Petersen C, Werner R.

Strahlenther Onkol. 2018 Jun;194(6):570-579. doi: 10.1007/s00066-018-1264-8. Epub 2018 Feb 15.

PMID:
29450592
12.

Evaluation of the accuracy and clinical practicality of a calculation system for patient positional displacement in carbon ion radiotherapy at five sites.

Kubota Y, Hayashi H, Abe S, Souda S, Okada R, Ishii T, Tashiro M, Torikoshi M, Kanai T, Ohno T, Nakano T.

J Appl Clin Med Phys. 2018 Mar;19(2):144-153. doi: 10.1002/acm2.12261. Epub 2018 Jan 25.

13.

Real-time beam monitoring for error detection in IMRT plans and impact on dose-volume histograms : A multi-center study.

Marrazzo L, Arilli C, Pasler M, Kusters M, Canters R, Fedeli L, Calusi S, Casati M, Talamonti C, Simontacchi G, Livi L, Pallotta S.

Strahlenther Onkol. 2018 Mar;194(3):243-254. doi: 10.1007/s00066-017-1245-3. Epub 2017 Dec 18.

PMID:
29255923
14.
15.

Multi-institutional comparison of simulated treatment delivery errors in ssIMRT, manually planned VMAT and autoplan-VMAT plans for nasopharyngeal radiotherapy.

Pogson EM, Aruguman S, Hansen CR, Currie M, Oborn BM, Blake SJ, Juresic J, Ochoa C, Yakobi J, Haman A, Trtovac A, Carolan M, Holloway L, Thwaites DI.

Phys Med. 2017 Oct;42:55-66. doi: 10.1016/j.ejmp.2017.08.008. Epub 2017 Sep 4.

PMID:
29173921
16.

Deep-Inspiration Breath-Hold Intensity Modulated Radiation Therapy to the Mediastinum for Lymphoma Patients: Setup Uncertainties and Margins.

Aristophanous M, Chi PM, Kao J, Williamson R, Tung S, Andraos T, Milgrom SA, Pinnix CC, Dabaja BS.

Int J Radiat Oncol Biol Phys. 2018 Jan 1;100(1):254-262. doi: 10.1016/j.ijrobp.2017.09.036. Epub 2017 Sep 25.

PMID:
29100788
17.

A robust optimisation approach accounting for the effect of fractionation on setup uncertainties.

Lowe M, Aitkenhead A, Albertini F, Lomax AJ, MacKay RI.

Phys Med Biol. 2017 Oct 4;62(20):8178-8196. doi: 10.1088/1361-6560/aa8c58.

PMID:
28901947
18.

Comparison of initial patient setup accuracy between surface imaging and three point localization: A retrospective analysis.

Stanley DN, McConnell KA, Kirby N, Gutiérrez AN, Papanikolaou N, Rasmussen K.

J Appl Clin Med Phys. 2017 Nov;18(6):58-61. doi: 10.1002/acm2.12183. Epub 2017 Sep 13.

19.

Combined influence of CT random noise and HU-RSP calibration curve nonlinearities on proton range systematic errors.

Brousmiche S, Souris K, de Xivry JO, Lee JA, Macq B, Seco J.

Phys Med Biol. 2017 Oct 12;62(21):8226-8245. doi: 10.1088/1361-6560/aa86e9.

PMID:
28817383
20.

Photon caliper to achieve submillimeter positioning accuracy.

Gallagher KJ, Wong J, Zhang J.

Phys Med Biol. 2017 Sep 1;62(18):N404-N416. doi: 10.1088/1361-6560/aa8493.

PMID:
28783038