Format
Sort by
Items per page

Send to

Choose Destination

Search results

Items: 1 to 50 of 351

1.

Monitoring diffuse injury during disease progression in experimental autoimmune encephalomyelitis with on resonance variable delay multiple pulse (onVDMP) CEST MRI.

Thomas AM, Xu J, Calabresi PA, van Zijl PCM, Bulte JWM.

Neuroimage. 2019 Oct 9:116245. doi: 10.1016/j.neuroimage.2019.116245. [Epub ahead of print]

PMID:
31605825
2.

Quantification of whole-brain oxygenation extraction fraction and cerebral metabolic rate of oxygen consumption in adults with sickle cell anemia using individual T2 -based oxygenation calibrations.

Li W, Xu X, Liu P, Strouse JJ, Casella JF, Lu H, van Zijl PCM, Qin Q.

Magn Reson Med. 2019 Sep 4. doi: 10.1002/mrm.27972. [Epub ahead of print]

PMID:
31483528
3.

High-resolution creatine mapping of mouse brain at 11.7 T using non-steady-state chemical exchange saturation transfer.

Chen L, Wei Z, Cai S, Li Y, Liu G, Lu H, Weiss RG, van Zijl PCM, Xu J.

NMR Biomed. 2019 Aug 28:e4168. doi: 10.1002/nbm.4168. [Epub ahead of print]

PMID:
31461196
4.

Differential Changes in Functional Connectivity of Striatum-Prefrontal and Striatum-Motor Circuits in Premanifest Huntington's Disease.

Kronenbuerger M, Hua J, Bang JYA, Ultz KE, Miao X, Zhang X, Pekar JJ, van Zijl PCM, Duan W, Margolis RL, Ross CA.

Neurodegener Dis. 2019 Aug 14:1-10. doi: 10.1159/000501616. [Epub ahead of print]

PMID:
31412344
5.

Undersampled MR image reconstruction using an enhanced recursive residual network.

Bao L, Ye F, Cai C, Wu J, Zeng K, van Zijl PCM, Chen Z.

J Magn Reson. 2019 Aug;305:232-246. doi: 10.1016/j.jmr.2019.07.020. Epub 2019 Jul 9.

PMID:
31323504
6.

DeepHarmony: A deep learning approach to contrast harmonization across scanner changes.

Dewey BE, Zhao C, Reinhold JC, Carass A, Fitzgerald KC, Sotirchos ES, Saidha S, Oh J, Pham DL, Calabresi PA, van Zijl PCM, Prince JL.

Magn Reson Imaging. 2019 Jul 10. pii: S0730-725X(18)30649-0. doi: 10.1016/j.mri.2019.05.041. [Epub ahead of print]

PMID:
31301354
7.

Detecting acid phosphatase enzymatic activity with phenol as a chemical exchange saturation transfer magnetic resonance imaging contrast agent (PhenolCEST MRI).

Zhang J, Yuan Y, Han Z, Li Y, van Zijl PCM, Yang X, Bulte JWM, Liu G.

Biosens Bioelectron. 2019 Sep 15;141:111442. doi: 10.1016/j.bios.2019.111442. Epub 2019 Jun 20.

PMID:
31252256
8.

Prospective acceleration of parallel RF transmission-based 3D chemical exchange saturation transfer imaging with compressed sensing.

Heo HY, Xu X, Jiang S, Zhao Y, Keupp J, Redmond KJ, Laterra J, van Zijl PCM, Zhou J.

Magn Reson Med. 2019 Nov;82(5):1812-1821. doi: 10.1002/mrm.27875. Epub 2019 Jun 17.

PMID:
31209938
9.

Carbon Dots as a New Class of Diamagnetic Chemical Exchange Saturation Transfer (diaCEST) MRI Contrast Agents.

Zhang J, Yuan Y, Gao M, Han Z, Chu C, Li Y, van Zijl PCM, Ying M, Bulte JWM, Liu G.

Angew Chem Int Ed Engl. 2019 Jul 15;58(29):9871-9875. doi: 10.1002/anie.201904722. Epub 2019 Jun 24.

PMID:
31162873
10.

CEST MRI monitoring of tumor response to vascular disrupting therapy using high molecular weight dextrans.

Chen H, Liu D, Li Y, Xu X, Xu J, Yadav NN, Zhou S, van Zijl PCM, Liu G.

Magn Reson Med. 2019 Oct;82(4):1471-1479. doi: 10.1002/mrm.27818. Epub 2019 May 20.

PMID:
31106918
11.

Molecular Imaging of Deoxycytidine Kinase Activity Using Deoxycytidine-Enhanced CEST MRI.

Han Z, Li Y, Zhang J, Liu J, Chen C, van Zijl PC, Liu G.

Cancer Res. 2019 May 15;79(10):2775-2783. doi: 10.1158/0008-5472.CAN-18-3565. Epub 2019 Apr 2.

PMID:
30940660
12.

Extradomain-B Fibronectin-Targeted Dextran-Based Chemical Exchange Saturation Transfer Magnetic Resonance Imaging Probe for Detecting Pancreatic Cancer.

Han Z, Zhang S, Fujiwara K, Zhang J, Li Y, Liu J, van Zijl PCM, Lu ZR, Zheng L, Liu G.

Bioconjug Chem. 2019 May 15;30(5):1425-1433. doi: 10.1021/acs.bioconjchem.9b00161. Epub 2019 Apr 15.

PMID:
30938983
13.

The effect of the mTOR inhibitor rapamycin on glucoCEST signal in a preclinical model of glioblastoma.

Xu X, Xu J, Knutsson L, Liu J, Liu H, Li Y, Lal B, Laterra J, Artemov D, Liu G, van Zijl PCM, Chan KWY.

Magn Reson Med. 2019 Jun;81(6):3798-3807. doi: 10.1002/mrm.27683. Epub 2019 Feb 22.

PMID:
30793789
14.

Effect of disease-modifying therapies on subcortical gray matter atrophy in multiple sclerosis.

Sotirchos ES, Gonzalez-Caldito N, Dewey BE, Fitzgerald KC, Glaister J, Filippatou A, Ogbuokiri E, Feldman S, Kwakyi O, Risher H, Crainiceanu C, Pham DL, Van Zijl PC, Mowry EM, Reich DS, Prince JL, Calabresi PA, Saidha S.

Mult Scler. 2019 Feb 11:1352458519826364. doi: 10.1177/1352458519826364. [Epub ahead of print]

PMID:
30741108
15.

Increased cerebral blood volume in small arterial vessels is a correlate of amyloid-β-related cognitive decline.

Hua J, Lee S, Blair NIS, Wyss M, van Bergen JMG, Schreiner SJ, Kagerer SM, Leh SE, Gietl AF, Treyer V, Buck A, Nitsch RM, Pruessmann KP, Lu H, Van Zijl PCM, Albert M, Hock C, Unschuld PG.

Neurobiol Aging. 2019 Apr;76:181-193. doi: 10.1016/j.neurobiolaging.2019.01.001. Epub 2019 Jan 10.

16.

Multi-atlas tool for automated segmentation of brain gray matter nuclei and quantification of their magnetic susceptibility.

Li X, Chen L, Kutten K, Ceritoglu C, Li Y, Kang N, Hsu JT, Qiao Y, Wei H, Liu C, Miller MI, Mori S, Yousem DM, van Zijl PCM, Faria AV.

Neuroimage. 2019 May 1;191:337-349. doi: 10.1016/j.neuroimage.2019.02.016. Epub 2019 Feb 7.

PMID:
30738207
17.

Cerebral blood volume mapping using Fourier-transform-based velocity-selective saturation pulse trains.

Qin Q, Qu Y, Li W, Liu D, Shin T, Zhao Y, Lin DD, van Zijl PCM, Wen Z.

Magn Reson Med. 2019 Jun;81(6):3544-3554. doi: 10.1002/mrm.27668. Epub 2019 Feb 8.

PMID:
30737847
18.

APT-weighted MRI: Techniques, current neuro applications, and challenging issues.

Zhou J, Heo HY, Knutsson L, van Zijl PCM, Jiang S.

J Magn Reson Imaging. 2019 Aug;50(2):347-364. doi: 10.1002/jmri.26645. Epub 2019 Jan 20. Review.

PMID:
30663162
19.

Quantifying amide proton exchange rate and concentration in chemical exchange saturation transfer imaging of the human brain.

Heo HY, Han Z, Jiang S, Schär M, van Zijl PCM, Zhou J.

Neuroimage. 2019 Apr 1;189:202-213. doi: 10.1016/j.neuroimage.2019.01.034. Epub 2019 Jan 14.

PMID:
30654175
20.

Arterial Input Functions and Tissue Response Curves in Dynamic Glucose-Enhanced (DGE) Imaging: Comparison Between glucoCEST and Blood Glucose Sampling in Humans.

Knutsson L, Seidemo A, Rydhög Scherman A, Markenroth Bloch K, Kalyani RR, Andersen M, Sundgren PC, Wirestam R, Helms G, van Zijl PCM, Xu X.

Tomography. 2018 Dec;4(4):164-171. doi: 10.18383/j.tom.2018.00025.

21.

Protein aggregation linked to Alzheimer's disease revealed by saturation transfer MRI.

Chen L, Wei Z, Chan KWY, Cai S, Liu G, Lu H, Wong PC, van Zijl PCM, Li T, Xu J.

Neuroimage. 2019 Mar;188:380-390. doi: 10.1016/j.neuroimage.2018.12.018. Epub 2018 Dec 13.

PMID:
30553917
22.

Altered brain iron content and deposition rate in Huntington's disease as indicated by quantitative susceptibility MRI.

Chen L, Hua J, Ross CA, Cai S, van Zijl PCM, Li X.

J Neurosci Res. 2019 Apr;97(4):467-479. doi: 10.1002/jnr.24358. Epub 2018 Nov 29.

23.

Altered functional connectivity between sub-regions in the thalamus and cortex in schizophrenia patients measured by resting state BOLD fMRI at 7T.

Hua J, Blair NIS, Paez A, Choe A, Barber AD, Brandt A, Lim IAL, Xu F, Kamath V, Pekar JJ, van Zijl PCM, Ross CA, Margolis RL.

Schizophr Res. 2019 Apr;206:370-377. doi: 10.1016/j.schres.2018.10.016. Epub 2018 Nov 6.

PMID:
30409697
24.

Optimization of phase-contrast MRI for the estimation of global cerebral blood flow of mice at 11.7T.

Wei Z, Chen L, Lin Z, Jiang D, Xu J, Liu P, van Zijl PCM, Lu H.

Magn Reson Med. 2019 Apr;81(4):2566-2575. doi: 10.1002/mrm.27592. Epub 2018 Nov 4.

PMID:
30393888
25.

Identifying Recurrent Malignant Glioma after Treatment Using Amide Proton Transfer-Weighted MR Imaging: A Validation Study with Image-Guided Stereotactic Biopsy.

Jiang S, Eberhart CG, Lim M, Heo HY, Zhang Y, Blair L, Wen Z, Holdhoff M, Lin D, Huang P, Qin H, Quinones-Hinojosa A, Weingart JD, Barker PB, Pomper MG, Laterra J, van Zijl PCM, Blakeley JO, Zhou J.

Clin Cancer Res. 2019 Jan 15;25(2):552-561. doi: 10.1158/1078-0432.CCR-18-1233. Epub 2018 Oct 26.

PMID:
30366937
26.

Brain and retinal atrophy in African-Americans versus Caucasian-Americans with multiple sclerosis: a longitudinal study.

Caldito NG, Saidha S, Sotirchos ES, Dewey BE, Cowley NJ, Glaister J, Fitzgerald KC, Al-Louzi O, Nguyen J, Rothman A, Ogbuokiri E, Fioravante N, Feldman S, Kwakyi O, Risher H, Kimbrough D, Frohman TC, Frohman E, Balcer L, Crainiceanu C, Van Zijl PCM, Mowry EM, Reich DS, Oh J, Pham DL, Prince J, Calabresi PA.

Brain. 2018 Nov 1;141(11):3115-3129. doi: 10.1093/brain/awy245.

PMID:
30312381
27.

Background field removal for susceptibility mapping of human brain with large susceptibility variations.

Fang J, Bao L, Li X, van Zijl PCM, Chen Z.

Magn Reson Med. 2019 Mar;81(3):2025-2037. doi: 10.1002/mrm.27492. Epub 2018 Oct 9.

28.

Creatine and phosphocreatine mapping of mouse skeletal muscle by a polynomial and Lorentzian line-shape fitting CEST method.

Chen L, Barker PB, Weiss RG, van Zijl PCM, Xu J.

Magn Reson Med. 2019 Jan;81(1):69-78. doi: 10.1002/mrm.27514. Epub 2018 Sep 23.

PMID:
30246265
29.

Dynamic glucose enhanced MRI of the placenta in a mouse model of intrauterine inflammation.

Wu D, Xu J, Lei J, Mclane M, van Zijl PC, Burd I.

Placenta. 2018 Sep;69:86-91. doi: 10.1016/j.placenta.2018.07.012. Epub 2018 Jul 20.

PMID:
30213490
30.

CEST MRI of 3-O-methyl-D-glucose uptake and accumulation in brain tumors.

Sehgal AA, Li Y, Lal B, Yadav NN, Xu X, Xu J, Laterra J, van Zijl PCM.

Magn Reson Med. 2019 Mar;81(3):1993-2000. doi: 10.1002/mrm.27489. Epub 2018 Sep 11.

PMID:
30206994
31.

GlucoCEST imaging with on-resonance variable delay multiple pulse (onVDMP) MRI.

Xu X, Xu J, Chan KWY, Liu J, Liu H, Li Y, Chen L, Liu G, van Zijl PCM.

Magn Reson Med. 2019 Jan;81(1):47-56. doi: 10.1002/mrm.27364. Epub 2018 Jul 29.

PMID:
30058240
32.

Triazoles as T2 -Exchange Magnetic Resonance Imaging Contrast Agents for the Detection of Nitrilase Activity.

Zhang J, Han Z, Lu J, Li Y, Liao X, van Zijl PC, Yang X, Liu G.

Chemistry. 2018 Oct 9;24(56):15013-15018. doi: 10.1002/chem.201802663. Epub 2018 Sep 10.

PMID:
29989227
33.

CEST MRI of sepsis-induced acute kidney injury.

Liu J, Han Z, Chen G, Li Y, Zhang J, Xu J, van Zijl PCM, Zhang S, Liu G.

NMR Biomed. 2018 Aug;31(8):e3942. doi: 10.1002/nbm.3942. Epub 2018 Jun 13.

PMID:
29897643
34.

CEST, ASL, and magnetization transfer contrast: How similar pulse sequences detect different phenomena.

Knutsson L, Xu J, Ahlgren A, van Zijl PCM.

Magn Reson Med. 2018 Oct;80(4):1320-1340. doi: 10.1002/mrm.27341. Epub 2018 May 30. Review.

35.

MRI detection of bacterial brain abscesses and monitoring of antibiotic treatment using bacCEST.

Liu J, Bai R, Li Y, Staedtke V, Zhang S, van Zijl PCM, Liu G.

Magn Reson Med. 2018 Aug;80(2):662-671. doi: 10.1002/mrm.27180. Epub 2018 Mar 25.

36.

Simultaneous quantitative susceptibility mapping and Flutemetamol-PET suggests local correlation of iron and β-amyloid as an indicator of cognitive performance at high age.

van Bergen JMG, Li X, Quevenco FC, Gietl AF, Treyer V, Meyer R, Buck A, Kaufmann PA, Nitsch RM, van Zijl PCM, Hock C, Unschuld PG.

Neuroimage. 2018 Jul 1;174:308-316. doi: 10.1016/j.neuroimage.2018.03.021. Epub 2018 Mar 13.

37.

Salicylic Acid-Based Polymeric Contrast Agents for Molecular Magnetic Resonance Imaging of Prostate Cancer.

Banerjee SR, Song X, Yang X, Minn I, Lisok A, Chen Y, Bui A, Chatterjee S, Chen J, van Zijl PCM, McMahon MT, Pomper MG.

Chemistry. 2018 May 17;24(28):7235-7242. doi: 10.1002/chem.201800882. Epub 2018 Apr 26.

38.

Separating fast and slow exchange transfer and magnetization transfer using off-resonance variable-delay multiple-pulse (VDMP) MRI.

Chen L, Xu X, Zeng H, Chan KWY, Yadav N, Cai S, Schunke KJ, Faraday N, van Zijl PCM, Xu J.

Magn Reson Med. 2018 Oct;80(4):1568-1576. doi: 10.1002/mrm.27111. Epub 2018 Feb 5.

39.

Low cortical iron and high entorhinal cortex volume promote cognitive functioning in the oldest-old.

van Bergen JMG, Li X, Quevenco FC, Gietl AF, Treyer V, Leh SE, Meyer R, Buck A, Kaufmann PA, Nitsch RM, van Zijl PCM, Hock C, Unschuld PG.

Neurobiol Aging. 2018 Apr;64:68-75. doi: 10.1016/j.neurobiolaging.2017.12.014. Epub 2017 Dec 20.

40.

Phenols as Diamagnetic T2 -Exchange Magnetic Resonance Imaging Contrast Agents.

Zhang J, Li Y, Slania S, Yadav NN, Liu J, Wang R, Zhang J, Pomper MG, van Zijl PC, Yang X, Liu G.

Chemistry. 2018 Jan 26;24(6):1259-1263. doi: 10.1002/chem.201705772. Epub 2018 Jan 11.

41.

Characterization of tumor vascular permeability using natural dextrans and CEST MRI.

Li Y, Qiao Y, Chen H, Bai R, Staedtke V, Han Z, Xu J, Chan KWY, Yadav N, Bulte JWM, Zhou S, van Zijl PCM, Liu G.

Magn Reson Med. 2018 Feb;79(2):1001-1009. doi: 10.1002/mrm.27014. Epub 2017 Nov 28.

42.

Accounting for the role of hematocrit in between-subject variations of MRI-derived baseline cerebral hemodynamic parameters and functional BOLD responses.

Xu F, Li W, Liu P, Hua J, Strouse JJ, Pekar JJ, Lu H, van Zijl PCM, Qin Q.

Hum Brain Mapp. 2018 Jan;39(1):344-353. doi: 10.1002/hbm.23846. Epub 2017 Oct 11.

43.

Investigation of the contribution of total creatine to the CEST Z-spectrum of brain using a knockout mouse model.

Chen L, Zeng H, Xu X, Yadav NN, Cai S, Puts NA, Barker PB, Li T, Weiss RG, van Zijl PCM, Xu J.

NMR Biomed. 2017 Dec;30(12). doi: 10.1002/nbm.3834. Epub 2017 Sep 29.

44.

Detection of dynamic substrate binding using MRI.

Yadav NN, Yang X, Li Y, Li W, Liu G, van Zijl PCM.

Sci Rep. 2017 Aug 31;7(1):10138. doi: 10.1038/s41598-017-10545-1.

45.

Dynamic Susceptibility Contrast MRI at 7 T: Tail-Scaling Analysis and Inferences About Field Strength Dependence.

Knutsson L, Xu X, Ståhlberg F, Barker PB, Lind E, Sundgren PC, van Zijl PCM, Wirestam R.

Tomography. 2017 Jun;3(2):74-78. doi: 10.18383/j.tom.2017.00001.

46.

Consensus statement on current and emerging methods for the diagnosis and evaluation of cerebrovascular disease.

Donahue MJ, Achten E, Cogswell PM, De Leeuw FE, Derdeyn CP, Dijkhuizen RM, Fan AP, Ghaznawi R, Heit JJ, Ikram MA, Jezzard P, Jordan LC, Jouvent E, Knutsson L, Leigh R, Liebeskind DS, Lin W, Okell TW, Qureshi AI, Stagg CJ, van Osch MJ, van Zijl PC, Watchmaker JM, Wintermark M, Wu O, Zaharchuk G, Zhou J, Hendrikse J.

J Cereb Blood Flow Metab. 2018 Sep;38(9):1391-1417. doi: 10.1177/0271678X17721830. Epub 2017 Aug 17. Review.

47.

Language Mapping Using T2-Prepared BOLD Functional MRI in the Presence of Large Susceptibility Artifacts-Initial Results in Patients With Brain Tumor and Epilepsy.

Hua J, Miao X, Agarwal S, Bettegowda C, Quiñones-Hinojosa A, Laterra J, Van Zijl PCM, Pekar JJ, Pillai JJ.

Tomography. 2017 Jun;3(2):105-113. doi: 10.18383/j.tom.2017.00006.

48.

Whole-brain arteriography and venography: Using improved velocity-selective saturation pulse trains.

Li W, Xu F, Schär M, Liu J, Shin T, Zhao Y, van Zijl PCM, Wasserman BA, Qiao Y, Qin Q.

Magn Reson Med. 2018 Apr;79(4):2014-2023. doi: 10.1002/mrm.26864. Epub 2017 Aug 10.

49.

Predicting IDH mutation status in grade II gliomas using amide proton transfer-weighted (APTw) MRI.

Jiang S, Zou T, Eberhart CG, Villalobos MAV, Heo HY, Zhang Y, Wang Y, Wang X, Yu H, Du Y, van Zijl PCM, Wen Z, Zhou J.

Magn Reson Med. 2017 Sep;78(3):1100-1109. doi: 10.1002/mrm.26820. Epub 2017 Jul 16.

50.

GlucoCEST magnetic resonance imaging in vivo may be diagnostic of acute renal allograft rejection.

Kentrup D, Bovenkamp P, Busch A, Schuette-Nuetgen K, Pawelski H, Pavenstädt H, Schlatter E, Herrmann KH, Reichenbach JR, Löffler B, Heitplatz B, Van Marck V, Yadav NN, Liu G, van Zijl PCM, Reuter S, Hoerr V.

Kidney Int. 2017 Sep;92(3):757-764. doi: 10.1016/j.kint.2017.04.015. Epub 2017 Jul 12.

PMID:
28709641

Supplemental Content

Loading ...
Support Center