Format
Sort by
Items per page

Send to

Choose Destination

Search results

Items: 1 to 50 of 105

1.

A Novel Gradient Echo Plural Contrast Imaging Method Detects Brain Tissue Abnormalities in Patients With TBI Without Evident Anatomical Changes on Clinical MRI: A Pilot Study.

Astafiev SV, Wen J, Brody DL, Cross AH, Anokhin AP, Zinn KL, Corbetta M, Yablonskiy DA.

Mil Med. 2019 Mar 1;184(Suppl 1):218-227. doi: 10.1093/milmed/usy394.

PMID:
30901451
2.

Genetically defined cellular correlates of the baseline brain MRI signal.

Wen J, Goyal MS, Astafiev SV, Raichle ME, Yablonskiy DA.

Proc Natl Acad Sci U S A. 2018 Oct 9;115(41):E9727-E9736. doi: 10.1073/pnas.1808121115. Epub 2018 Sep 25.

3.

Single scan quantitative gradient recalled echo MRI for evaluation of tissue damage in lesions and normal appearing gray and white matter in multiple sclerosis.

Xiang B, Wen J, Cross AH, Yablonskiy DA.

J Magn Reson Imaging. 2019 Feb;49(2):487-498. doi: 10.1002/jmri.26218. Epub 2018 Aug 29.

PMID:
30155934
4.

Lorentzian effects in magnetic susceptibility mapping of anisotropic biological tissues.

Yablonskiy DA, Sukstanskii AL.

J Magn Reson. 2018 Jul;292:129-136. doi: 10.1016/j.jmr.2018.04.014. Epub 2018 Apr 26.

5.

Phase-sensitive B1 mapping: Effects of relaxation and RF spoiling.

Wen J, Sukstanskii AL, Yablonskiy DA.

Magn Reson Med. 2018 Jul;80(1):101-111. doi: 10.1002/mrm.27009. Epub 2017 Nov 20.

6.

Limbic system damage in MS: MRI assessment and correlations with clinical testing.

Wen J, Yablonskiy DA, Salter A, Cross AH.

PLoS One. 2017 Nov 9;12(11):e0187915. doi: 10.1371/journal.pone.0187915. eCollection 2017.

7.

What makes a good pediatric transplant lung: Insights from in vivo lung morphometry with hyperpolarized 3 He magnetic resonance imaging.

Fishman EF, Quirk JD, Sweet SC, Woods JC, Gierada DS, Conradi MS, Siegel MJ, Yablonskiy DA.

Pediatr Transplant. 2017 May;21(3). doi: 10.1111/petr.12886. Epub 2017 Jan 24.

8.

In vivo detection of microstructural correlates of brain pathology in preclinical and early Alzheimer Disease with magnetic resonance imaging.

Zhao Y, Raichle ME, Wen J, Benzinger TL, Fagan AM, Hassenstab J, Vlassenko AG, Luo J, Cairns NJ, Christensen JJ, Morris JC, Yablonskiy DA.

Neuroimage. 2017 Mar 1;148:296-304. doi: 10.1016/j.neuroimage.2016.12.026. Epub 2016 Dec 15.

9.
10.

On the relationship between cellular and hemodynamic properties of the human brain cortex throughout adult lifespan.

Zhao Y, Wen J, Cross AH, Yablonskiy DA.

Neuroimage. 2016 Jun;133:417-429. doi: 10.1016/j.neuroimage.2016.03.022. Epub 2016 Mar 17.

11.

Simultaneous multi-angular relaxometry of tissue with MRI (SMART MRI): Theoretical background and proof of concept.

Sukstanskii AL, Wen J, Cross AH, Yablonskiy DA.

Magn Reson Med. 2017 Mar;77(3):1296-1306. doi: 10.1002/mrm.26176. Epub 2016 Mar 15.

12.

Direct comparison of 129 Xe diffusion measurements with quantitative histology in human lungs.

Thomen RP, Quirk JD, Roach D, Egan-Rojas T, Ruppert K, Yusen RD, Altes TA, Yablonskiy DA, Woods JC.

Magn Reson Med. 2017 Jan;77(1):265-272. doi: 10.1002/mrm.26120. Epub 2016 Jan 17.

PMID:
26778748
13.

Diffusion lung imaging with hyperpolarized gas MRI.

Yablonskiy DA, Sukstanskii AL, Quirk JD.

NMR Biomed. 2017 Mar;30(3). doi: 10.1002/nbm.3448. Epub 2015 Dec 16. Review.

14.

Experimental evidence of age-related adaptive changes in human acinar airways.

Quirk JD, Sukstanskii AL, Woods JC, Lutey BA, Conradi MS, Gierada DS, Yusen RD, Castro M, Yablonskiy DA.

J Appl Physiol (1985). 2016 Jan 15;120(2):159-65. doi: 10.1152/japplphysiol.00541.2015. Epub 2015 Nov 5.

15.

Detection of cortical lesions in multiple sclerosis: A new imaging approach.

Patel KR, Luo J, Alvarez E, Piccio L, Schmidt RE, Yablonskiy DA, Cross AH.

Mult Scler J Exp Transl Clin. 2015 Sep 24;1:2055217315606465. doi: 10.1177/2055217315606465. eCollection 2015 Jan-Dec.

16.

Separation of cellular and BOLD contributions to T2* signal relaxation.

Ulrich X, Yablonskiy DA.

Magn Reson Med. 2016 Feb;75(2):606-15. doi: 10.1002/mrm.25610. Epub 2015 Mar 10.

17.

Detection and quantification of regional cortical gray matter damage in multiple sclerosis utilizing gradient echo MRI.

Wen J, Yablonskiy DA, Luo J, Lancia S, Hildebolt C, Cross AH.

Neuroimage Clin. 2015 Aug 18;9:164-75. doi: 10.1016/j.nicl.2015.08.003. eCollection 2015.

18.

Generalized Lorentzian Tensor Approach (GLTA) as a biophysical background for quantitative susceptibility mapping.

Yablonskiy DA, Sukstanskii AL.

Magn Reson Med. 2015 Feb;73(2):757-64. doi: 10.1002/mrm.25538. Epub 2014 Nov 26.

19.

Assessment of regional lung function with multivolume (1)H MR imaging in health and obstructive lung disease: comparison with (3)He MR imaging.

Pennati F, Quirk JD, Yablonskiy DA, Castro M, Aliverti A, Woods JC.

Radiology. 2014 Nov;273(2):580-90. doi: 10.1148/radiol.14132470. Epub 2014 Jun 15.

20.

Probing lung microstructure with hyperpolarized 3He gradient echo MRI.

Sukstanskii AL, Quirk JD, Yablonskiy DA.

NMR Biomed. 2014 Dec;27(12):1451-60. doi: 10.1002/nbm.3150. Epub 2014 Jun 11.

21.

In vivo lung morphometry with accelerated hyperpolarized (3) He diffusion MRI: a preliminary study.

Chang YV, Quirk JD, Yablonskiy DA.

Magn Reson Med. 2015 Apr;73(4):1609-14. doi: 10.1002/mrm.25284. Epub 2014 May 5.

22.

Lorentz sphere versus generalized Lorentzian approach: What would lorentz say about it?

Yablonskiy DA, He X, Luo J, Sukstanskii AL.

Magn Reson Med. 2014 Jul;72(1):4-7. doi: 10.1002/mrm.25230. Epub 2014 Apr 25. No abstract available.

23.

In vivo lung morphometry with hyperpolarized (3) He diffusion MRI: reproducibility and the role of diffusion-sensitizing gradient direction.

Quirk JD, Chang YV, Yablonskiy DA.

Magn Reson Med. 2015 Mar;73(3):1252-7. doi: 10.1002/mrm.25241. Epub 2014 Apr 21.

24.

Biophysical mechanisms of myelin-induced water frequency shifts.

Yablonskiy DA, Sukstanskii AL.

Magn Reson Med. 2014 Jun;71(6):1956-8. doi: 10.1002/mrm.25214. Epub 2014 Apr 3. No abstract available.

25.

On the role of physiological fluctuations in quantitative gradient echo MRI: implications for GEPCI, QSM, and SWI.

Wen J, Cross AH, Yablonskiy DA.

Magn Reson Med. 2015 Jan;73(1):195-203. doi: 10.1002/mrm.25114. Epub 2014 Jan 30.

26.

Commentary on "The influence of lung airways branching structure and diffusion time on measurements and models of short-range 3He gas MR diffusion".

Yablonskiy DA, Sukstanskii AL, Conradi MS.

J Magn Reson. 2014 Feb;239:139-42. doi: 10.1016/j.jmr.2013.09.019. Epub 2013 Nov 16.

27.

Gradient echo magnetic resonance imaging correlates with clinical measures and allows visualization of veins within multiple sclerosis lesions.

Luo J, Yablonskiy DA, Hildebolt CF, Lancia S, Cross AH.

Mult Scler. 2014 Mar;20(3):349-55. doi: 10.1177/1352458513495935. Epub 2013 Jul 8.

28.
29.

Probing lung microstructure with hyperpolarized noble gas diffusion MRI: theoretical models and experimental results.

Yablonskiy DA, Sukstanskii AL, Quirk JD, Woods JC, Conradi MS.

Magn Reson Med. 2014 Feb;71(2):486-505. doi: 10.1002/mrm.24729.

30.

On the role of neuronal magnetic susceptibility and structure symmetry on gradient echo MR signal formation.

Sukstanskii AL, Yablonskiy DA.

Magn Reson Med. 2014 Jan;71(1):345-53. doi: 10.1002/mrm.24629. Epub 2013 Feb 4.

31.

Commentaries on viewpoint: unresolved mysteries.

Weibel ER, Nieman GF, Gatto LA, Frazer DG, Schittny JC, Woods JC, Conradi MS, Yablonskiy DA.

J Appl Physiol (1985). 2012 Dec 15;113(12):1948-9. doi: 10.1152/japplphysiol.01203.2012. No abstract available.

32.

Voxel spread function method for correction of magnetic field inhomogeneity effects in quantitative gradient-echo-based MRI.

Yablonskiy DA, Sukstanskii AL, Luo J, Wang X.

Magn Reson Med. 2013 Nov;70(5):1283-92. doi: 10.1002/mrm.24585. Epub 2012 Dec 11.

33.
34.

Biophysical mechanisms of MRI signal frequency contrast in multiple sclerosis.

Yablonskiy DA, Luo J, Sukstanskii AL, Iyer A, Cross AH.

Proc Natl Acad Sci U S A. 2012 Aug 28;109(35):14212-7. doi: 10.1073/pnas.1206037109. Epub 2012 Aug 13.

35.

Evidence for adult lung growth in humans.

Butler JP, Loring SH, Patz S, Tsuda A, Yablonskiy DA, Mentzer SJ.

N Engl J Med. 2012 Jul 19;367(3):244-7. doi: 10.1056/NEJMoa1203983.

36.

Optimization strategies for evaluation of brain hemodynamic parameters with qBOLD technique.

Wang X, Sukstanskii AL, Yablonskiy DA.

Magn Reson Med. 2013 Apr;69(4):1034-43. doi: 10.1002/mrm.24338. Epub 2012 May 23.

37.

Gradient echo plural contrast imaging--signal model and derived contrasts: T2*, T1, phase, SWI, T1f, FST2*and T2*-SWI.

Luo J, Jagadeesan BD, Cross AH, Yablonskiy DA.

Neuroimage. 2012 Apr 2;60(2):1073-82. doi: 10.1016/j.neuroimage.2012.01.108. Epub 2012 Jan 28.

38.

Transmembrane dynamics of water exchange in human brain.

He X, Raichle ME, Yablonskiy DA.

Magn Reson Med. 2012 Feb;67(2):562-71. doi: 10.1002/mrm.23019. Epub 2011 Aug 29.

39.

Morphometric changes in the human pulmonary acinus during inflation.

Hajari AJ, Yablonskiy DA, Sukstanskii AL, Quirk JD, Conradi MS, Woods JC.

J Appl Physiol (1985). 2012 Mar;112(6):937-43. doi: 10.1152/japplphysiol.00768.2011. Epub 2011 Nov 17.

40.

Quantitative phenomenological model of the BOLD contrast mechanism.

Dickson JD, Ash TW, Williams GB, Sukstanskii AL, Ansorge RE, Yablonskiy DA.

J Magn Reson. 2011 Sep;212(1):17-25. doi: 10.1016/j.jmr.2011.06.003. Epub 2011 Jun 13.

41.

In vivo detection of acinar microstructural changes in early emphysema with (3)He lung morphometry.

Quirk JD, Lutey BA, Gierada DS, Woods JC, Senior RM, Lefrak SS, Sukstanskii AL, Conradi MS, Yablonskiy DA.

Radiology. 2011 Sep;260(3):866-74. doi: 10.1148/radiol.11102226. Epub 2011 Jul 6.

42.

Lung morphometry with hyperpolarized 129Xe: theoretical background.

Sukstanskii AL, Yablonskiy DA.

Magn Reson Med. 2012 Mar;67(3):856-66. doi: 10.1002/mrm.23056. Epub 2011 Jun 28.

43.

Cerebral metabolic rate in hypercapnia: controversy continues.

Yablonskiy DA.

J Cereb Blood Flow Metab. 2011 Jul;31(7):1502-3. doi: 10.1038/jcbfm.2011.32. Epub 2011 Mar 23. No abstract available.

44.

Imaging alveolar-duct geometry during expiration via ³He lung morphometry.

Hajari AJ, Yablonskiy DA, Quirk JD, Sukstanskii AL, Pierce RA, Deslée G, Conradi MS, Woods JC.

J Appl Physiol (1985). 2011 May;110(5):1448-54. doi: 10.1152/japplphysiol.01352.2010. Epub 2011 Feb 24.

45.

Imaging lung microstructure in mice with hyperpolarized 3He diffusion MRI.

Wang W, Nguyen NM, Yablonskiy DA, Sukstanskii AL, Osmanagic E, Atkinson JJ, Conradi MS, Woods JC.

Magn Reson Med. 2011 Mar;65(3):620-6. doi: 10.1002/mrm.22737. Epub 2010 Dec 16.

46.

³He lung morphometry technique: accuracy analysis and pulse sequence optimization.

Sukstanskii AL, Conradi MS, Yablonskiy DA.

J Magn Reson. 2010 Dec;207(2):234-41. doi: 10.1016/j.jmr.2010.09.005. Epub 2010 Sep 16.

47.

Theoretical models of the diffusion weighted MR signal.

Yablonskiy DA, Sukstanskii AL.

NMR Biomed. 2010 Aug;23(7):661-81. doi: 10.1002/nbm.1520. Review.

48.

Emphysema quantification in inflation-fixed lungs using low-dose computed tomography and 3He magnetic resonance imaging.

Gierada DS, Woods JC, Jacob RE, Bierhals AJ, Choong CK, Bartel ST, Chang YV, Das NA, Hong C, Lutey BA, Ritter JH, Pilgram TK, Cooper JD, Patterson GA, Battafarano RJ, Meyers BF, Yablonskiy DA, Conradi MS.

J Comput Assist Tomogr. 2010 Sep-Oct;34(5):773-9. doi: 10.1097/RCT.0b013e3181e480f9.

49.

Commentaries on Viewpoint: Standards for quantitative assessment of lung structure. Quantifying lung microstructure by MRI with hyperpolarized gases.

Yablonskiy DA.

J Appl Physiol (1985). 2010 Sep;109(3):936; author reply 937. No abstract available.

PMID:
20848743
50.

Quantitative assessment of lung microstructure in healthy mice using an MR-based 3He lung morphometry technique.

Osmanagic E, Sukstanskii AL, Quirk JD, Woods JC, Pierce RA, Conradi MS, Weibel ER, Yablonskiy DA.

J Appl Physiol (1985). 2010 Dec;109(6):1592-9. doi: 10.1152/japplphysiol.00736.2010. Epub 2010 Aug 26.

Supplemental Content

Loading ...
Support Center