Format
Sort by
Items per page

Send to

Choose Destination

Search results

Items: 1 to 50 of 311

1.

Relationship Between Pregnancy Complications and Subsequent Coronary Artery Disease Assessed by Coronary Computed Tomographic Angiography in Black Women.

Wichmann JL, Takx RAP, Nunez JH, Vliegenthart R, Otani K, Litwin SE, Morris PB, De Cecco CN, Rosenberg RD, Bayer RR 2nd, Baumann S, Renker M, Vogl TJ, Wenger NK, Schoepf UJ.

Circ Cardiovasc Imaging. 2019 Jul;12(7):e008754. doi: 10.1161/CIRCIMAGING.118.008754. Epub 2019 Jul 15.

PMID:
31303028
2.

Dual energy computed tomography virtual monoenergetic imaging: technique and clinical applications.

D'Angelo T, Cicero G, Mazziotti S, Ascenti G, Albrecht MH, Martin SS, Othman AE, Vogl TJ, Wichmann JL.

Br J Radiol. 2019 Jun;92(1098):20180546. doi: 10.1259/bjr.20180546. Epub 2019 Apr 9. Review.

PMID:
30919651
3.

Advanced Virtual Monoenergetic Imaging: Improvement of Visualization and Differentiation of Intramuscular Lesions in Portal-Venous-phase Contrast-enhanced Dual-energy CT.

Kraus MS, Selo N, Kiefer LS, Esser M, Albtoush OM, Weiss J, Wichmann JL, Bamberg F, Othman AE.

Acad Radiol. 2019 Mar 14. pii: S1076-6332(19)30080-7. doi: 10.1016/j.acra.2019.02.014. [Epub ahead of print]

PMID:
30879946
4.

Modified calcium subtraction in dual-energy CT angiography of the lower extremity runoff: impact on diagnostic accuracy for stenosis detection.

De Santis D, De Cecco CN, Schoepf UJ, Nance JW, Yamada RT, Thomas BA, Otani K, Jacobs BE, Turner DA, Wichmann JL, Eid M, Varga-Szemes A, Caruso D, Grant KL, Schmidt B, Vogl TJ, Laghi A, Albrecht MH.

Eur Radiol. 2019 Feb 25. doi: 10.1007/s00330-019-06032-y. [Epub ahead of print]

PMID:
30805703
5.

Comparison of Radiation Dose and Image Quality of Contrast-Enhanced Dual-Source CT of the Chest: Single-Versus Dual-Energy and Second-Versus Third-Generation Technology.

Lenga L, Leithner D, Peterke JL, Albrecht MH, Gudauskas T, D'Angelo T, Booz C, Hammerstingl R, Vogl TJ, Martin SS, Wichmann JL.

AJR Am J Roentgenol. 2019 Apr;212(4):741-747. doi: 10.2214/AJR.18.20065. Epub 2019 Jan 30.

PMID:
30699006
6.

Single- and dual-energy CT pulmonary angiography using second- and third-generation dual-source CT systems: comparison of radiation dose and image quality.

Lenga L, Trapp F, Albrecht MH, Wichmann JL, Johnson AA, Yel I, D'Angelo T, Booz C, Vogl TJ, Martin SS.

Eur Radiol. 2019 Jan 21. doi: 10.1007/s00330-018-5982-1. [Epub ahead of print]

PMID:
30666446
7.

Diagnostic Accuracy of Noncontrast Self-navigated Free-breathing MR Angiography versus CT Angiography: A Prospective Study in Pediatric Patients with Suspected Anomalous Coronary Arteries.

Albrecht MH, Varga-Szemes A, Schoepf UJ, Nance JW, De Cecco CN, De Santis D, Tesche C, Eid MH, Penmetsa M, Lesslie VW, Piccini D, Goeller M, Wichmann JL, Vogl TJ, Chowdhury SM, Nutting A, Hlavacek AM.

Acad Radiol. 2019 Jan 14. pii: S1076-6332(19)30003-0. doi: 10.1016/j.acra.2018.12.010. [Epub ahead of print]

PMID:
30655052
8.

Virtual Noncalcium Dual-Energy CT: Detection of Lumbar Disk Herniation in Comparison with Standard Gray-scale CT.

Booz C, Nöske J, Martin SS, Albrecht MH, Yel I, Lenga L, Gruber-Rouh T, Eichler K, D'Angelo T, Vogl TJ, Wichmann JL.

Radiology. 2019 Feb;290(2):446-455. doi: 10.1148/radiol.2018181286. Epub 2018 Dec 4.

PMID:
30615548
9.

Human lung tissue provides highly relevant data about efficacy of new anti-asthmatic drugs.

Danov O, Jiménez Delgado SM, Obernolte H, Seehase S, Dehmel S, Braubach P, Fieguth HG, Matschiner G, Fitzgerald M, Jonigk D, Knauf S, Pfennig O, Warnecke G, Wichmann J, Braun A, Sewald K.

PLoS One. 2018 Nov 30;13(11):e0207767. doi: 10.1371/journal.pone.0207767. eCollection 2018.

10.

Dual-energy CT in early acute pancreatitis: improved detection using iodine quantification.

Martin SS, Trapp F, Wichmann JL, Albrecht MH, Lenga L, Durden J, Booz C, Vogl TJ, D'Angelo T.

Eur Radiol. 2019 May;29(5):2226-2232. doi: 10.1007/s00330-018-5844-x. Epub 2018 Nov 28.

PMID:
30488112
11.

Multi-observer comparison study between unenhanced quiescent-interval single-shot magnetic resonance angiography and invasive carbon dioxide angiography in patients with peripheral arterial disease and chronic renal insufficiency.

Arendt CT, Leithner D, Lenga L, Wichmann JL, Albrecht MH, Czwikla R, Varga-Szemes A, d'Angelo T, Martin SS, Thalhammer A, Nagel E, Vogl TJ, Gruber-Rouh T.

Eur J Radiol. 2018 Nov;108:140-146. doi: 10.1016/j.ejrad.2018.09.029. Epub 2018 Sep 28.

PMID:
30396647
12.

Virtual non-enhanced dual-energy CT reconstruction may replace true non-enhanced CT scans in the setting of suspected active hemorrhage.

Walter SS, Schneeweiß S, Maurer M, Kraus MS, Wichmann JL, Bongers MN, Lescan M, Bamberg F, Othman AE.

Eur J Radiol. 2018 Dec;109:218-222. doi: 10.1016/j.ejrad.2018.10.026. Epub 2018 Oct 28.

PMID:
30392950
13.

Comparison of thick- and thin-slice images in thoracoabdominal trauma CT: a retrospective analysis.

Guchlerner L, Wichmann JL, Tischendorf P, Albrecht M, Vogl TJ, Wutzler S, Ackermann H, Eichler K, Frellesen C.

Eur J Trauma Emerg Surg. 2018 Sep 28. doi: 10.1007/s00068-018-1021-9. [Epub ahead of print]

PMID:
30267119
14.

Factors associated with parent-reported wheeze and cough in children living in an industrial area of Gauteng, South Africa.

Olutola BG, Claassen N, Wichmann J, Voyi K.

Environ Sci Pollut Res Int. 2018 Nov;25(33):33455-33463. doi: 10.1007/s11356-018-3304-4. Epub 2018 Sep 28.

PMID:
30264349
15.

Evaluation of Radiation Dose and Image Quality using High-Pitch 70-kV Chest CT in Immunosuppressed Patients.

Yel I, Martin SS, Wichmann JL, Lenga L, Albrecht MH, Bucher AM, Kaltenbach B, Polkowski C, Booz C, Vogl TJ, Hammerstingl RM.

Rofo. 2019 Feb;191(2):122-129. doi: 10.1055/a-0668-6031. Epub 2018 Sep 4. English, German.

16.

Improved long-term durability of allogeneic heart valves in the orthotopic sheep model.

Biermann AC, Marzi J, Brauchle E, Wichmann JL, Arendt CT, Puntmann V, Nagel E, Abdelaziz S, Winter AG, Brockbank KGM, Layland S, Schenke-Layland K, Stock UA.

Eur J Cardiothorac Surg. 2019 Mar 1;55(3):484-493. doi: 10.1093/ejcts/ezy292.

PMID:
30165639
17.

Dual-energy CT in patients with colorectal cancer: Improved assessment of hypoattenuating liver metastases using noise-optimized virtual monoenergetic imaging.

Lenga L, Czwikla R, Wichmann JL, Leithner D, Albrecht MH, Booz C, Arendt CT, Yel I, D'Angelo T, Vogl TJ, Martin SS.

Eur J Radiol. 2018 Sep;106:184-191. doi: 10.1016/j.ejrad.2018.07.027. Epub 2018 Jul 31.

PMID:
30150043
18.

Synthetic metabolic pathways for photobiological conversion of CO2 into hydrocarbon fuel.

Yunus IS, Wichmann J, Wördenweber R, Lauersen KJ, Kruse O, Jones PR.

Metab Eng. 2018 Sep;49:201-211. doi: 10.1016/j.ymben.2018.08.008. Epub 2018 Aug 23.

PMID:
30144559
19.

Evaluation of a Computer-Aided Diagnosis System for Automated Bone Age Assessment in Comparison to the Greulich-Pyle Atlas Method: A Multireader Study.

Booz C, Wichmann JL, Boettger S, Al Kamali A, Martin SS, Lenga L, Leithner D, Albrecht MH, Ackermann H, Vogl TJ, Bodelle B, Kaltenbach B.

J Comput Assist Tomogr. 2019 Jan/Feb;43(1):39-45. doi: 10.1097/RCT.0000000000000786.

PMID:
30119064
20.

Inhibitors of histone acetyltransferases KAT6A/B induce senescence and arrest tumour growth.

Baell JB, Leaver DJ, Hermans SJ, Kelly GL, Brennan MS, Downer NL, Nguyen N, Wichmann J, McRae HM, Yang Y, Cleary B, Lagiakos HR, Mieruszynski S, Pacini G, Vanyai HK, Bergamasco MI, May RE, Davey BK, Morgan KJ, Sealey AJ, Wang B, Zamudio N, Wilcox S, Garnham AL, Sheikh BN, Aubrey BJ, Doggett K, Chung MC, de Silva M, Bentley J, Pilling P, Hattarki M, Dolezal O, Dennis ML, Falk H, Ren B, Charman SA, White KL, Rautela J, Newbold A, Hawkins ED, Johnstone RW, Huntington ND, Peat TS, Heath JK, Strasser A, Parker MW, Smyth GK, Street IP, Monahan BJ, Voss AK, Thomas T.

Nature. 2018 Aug;560(7717):253-257. doi: 10.1038/s41586-018-0387-5. Epub 2018 Aug 1.

PMID:
30069049
21.

Intron-containing algal transgenes mediate efficient recombinant gene expression in the green microalga Chlamydomonas reinhardtii.

Baier T, Wichmann J, Kruse O, Lauersen KJ.

Nucleic Acids Res. 2018 Jul 27;46(13):6909-6919. doi: 10.1093/nar/gky532.

22.

Phototrophic production of heterologous diterpenoids and a hydroxy-functionalized derivative from Chlamydomonas reinhardtii.

Lauersen KJ, Wichmann J, Baier T, Kampranis SC, Pateraki I, Møller BL, Kruse O.

Metab Eng. 2018 Sep;49:116-127. doi: 10.1016/j.ymben.2018.07.005. Epub 2018 Jul 12.

PMID:
30017797
23.

Indication of whole body computed tomography in pediatric polytrauma patients-Diagnostic potential of the Glasgow Coma Scale, the mechanism of injury and clinical examination.

Frellesen C, Klein D, Tischendorf P, Wichmann JL, Wutzler S, Frank J, Ackermann H, Vogl TJ, Albrecht MH, Eichler K.

Eur J Radiol. 2018 Aug;105:32-40. doi: 10.1016/j.ejrad.2018.05.022. Epub 2018 May 25.

PMID:
30017296
24.

Dual-energy CT-based iodine quantification to differentiate abdominal malignant lymphoma from lymph node metastasis.

Martin SS, Czwikla R, Wichmann JL, Albrecht MH, Lenga L, Savage RH, Arendt C, Hammerstingl R, Vogl TJ, Kaltenbach B.

Eur J Radiol. 2018 Aug;105:255-260. doi: 10.1016/j.ejrad.2018.06.017. Epub 2018 Jun 22.

PMID:
30017291
25.

Iodine quantification to distinguish hepatic neuroendocrine tumor metastasis from hepatocellular carcinoma at dual-source dual-energy liver CT.

Kaltenbach B, Wichmann JL, Pfeifer S, Albrecht MH, Booz C, Lenga L, Hammerstingl R, D'Angelo T, Vogl TJ, Martin SS.

Eur J Radiol. 2018 Aug;105:20-24. doi: 10.1016/j.ejrad.2018.05.019. Epub 2018 May 19.

PMID:
30017280
26.

Dual-energy CT in patients with abdominal malignant lymphoma: impact of noise-optimised virtual monoenergetic imaging on objective and subjective image quality.

Lenga L, Czwikla R, Wichmann JL, Leithner D, Albrecht MH, D'Angelo T, Arendt CT, Booz C, Hammerstingl R, Vogl TJ, Martin SS.

Clin Radiol. 2018 Sep;73(9):833.e19-833.e27. doi: 10.1016/j.crad.2018.04.015. Epub 2018 Jun 5.

PMID:
29884524
27.

From low-dose to no-dose: thin-section magnetic resonance imaging for evaluation of pulmonary nodules.

D'Angelo T, Vogl TJ, Wichmann JL.

J Thorac Dis. 2018 Apr;10(Suppl 9):S1055-S1057. doi: 10.21037/jtd.2018.04.65. No abstract available.

28.

90-kVp low-tube-voltage CT pulmonary angiography in combination with advanced modeled iterative reconstruction algorithm: effects on radiation dose, image quality and diagnostic accuracy for the detection of pulmonary embolism.

Leithner D, Gruber-Rouh T, Beeres M, Wichmann JL, Mahmoudi S, Martin SS, Lenga L, Albrecht MH, Booz C, Vogl TJ, Scholtz JE.

Br J Radiol. 2018 Jul;91(1088):20180269. doi: 10.1259/bjr.20180269. Epub 2018 Jun 5.

PMID:
29792729
29.

Dynamic 4D-CT Angiography for Guiding Transarterial Chemoembolization: Impact on the Reduction of Contrast Material, Operator Radiation Exposure, Catheter Consumption, and Diagnostic Confidence.

Albrecht MH, Vogl TJ, Wichmann JL, Martin SS, Scholtz JE, Fischer S, Hammerstingl RM, Harth M, Nour-Eldin NA, Thalhammer A, Zangos S, Bauer RW.

Rofo. 2018 Jun;190(6):513-520. doi: 10.1055/a-0595-7964. Epub 2018 May 15.

30.

Patchoulol Production with Metabolically Engineered Corynebacterium glutamicum.

Henke NA, Wichmann J, Baier T, Frohwitter J, Lauersen KJ, Risse JM, Peters-Wendisch P, Kruse O, Wendisch VF.

Genes (Basel). 2018 Apr 17;9(4). pii: E219. doi: 10.3390/genes9040219.

31.

Respiratory Health Symptoms among Schoolchildren in Relation to Possible Food-Related Risk and Protective Factors.

Wright CY, Nkosi V, Wichmann J.

Int J Environ Res Public Health. 2018 Mar 13;15(3). pii: E502. doi: 10.3390/ijerph15030502.

32.

Diagnostic yield of 90-kVp low-tube-voltage carotid and intracerebral CT-angiography: effects on radiation dose, image quality and diagnostic performance for the detection of carotid stenosis.

Leithner D, Wichmann JL, Mahmoudi S, Martin SS, Albrecht MH, Vogl TJ, Scholtz JE.

Br J Radiol. 2018 Jun;91(1086):20170927. doi: 10.1259/bjr.20170927. Epub 2018 Mar 8.

33.

Dual-Energy Computed Tomography-Based Display of Bone Marrow Edema in Incidental Vertebral Compression Fractures: Diagnostic Accuracy and Characterization in Oncological Patients Undergoing Routine Staging Computed Tomography.

Frellesen C, Azadegan M, Martin SS, Otani K, DʼAngelo T, Booz C, Eichler K, Panahi B, Kaup M, Bauer RW, Vogl TJ, Wichmann JL.

Invest Radiol. 2018 Jul;53(7):409-416. doi: 10.1097/RLI.0000000000000458.

PMID:
29489560
34.

A noise-optimized virtual monoenergetic reconstruction algorithm improves the diagnostic accuracy of late hepatic arterial phase dual-energy CT for the detection of hypervascular liver lesions.

De Cecco CN, Caruso D, Schoepf UJ, De Santis D, Muscogiuri G, Albrecht MH, Meinel FG, Wichmann JL, Burchett PF, Varga-Szemes A, Sheafor DH, Hardie AD.

Eur Radiol. 2018 Aug;28(8):3393-3404. doi: 10.1007/s00330-018-5313-6. Epub 2018 Feb 19.

PMID:
29460075
35.

Using coronary CT angiography for guiding invasive coronary angiography: potential role to reduce intraprocedural radiation exposure.

Arendt CT, Tischendorf P, Wichmann JL, Messerli M, Jörg L, Ehl N, Gohmann RF, Wildermuth S, Vogl TJ, Bauer RW.

Eur Radiol. 2018 Jul;28(7):2756-2762. doi: 10.1007/s00330-018-5317-2. Epub 2018 Feb 7.

PMID:
29417250
36.

Validating Baboon Ex Vivo and In Vivo Radiation-Related Gene Expression with Corresponding Human Data.

Port M, Majewski M, Herodin F, Valente M, Drouet M, Forcheron F, Tichy A, Sirak I, Zavrelova A, Malkova A, Becker BV, Veit DA, Waldeck S, Badie C, O'Brien G, Christiansen H, Wichmann J, Eder M, Beutel G, Vachelova J, Doucha-Senf S, Abend M.

Radiat Res. 2018 Apr;189(4):389-398. doi: 10.1667/RR14958.1. Epub 2018 Jan 26.

PMID:
29373091
37.

Evaluation of virtual monoenergetic imaging algorithms for dual-energy carotid and intracerebral CT angiography: Effects on image quality, artefacts and diagnostic performance for the detection of stenosis.

Leithner D, Mahmoudi S, Wichmann JL, Martin SS, Lenga L, Albrecht MH, Booz C, Arendt CT, Beeres M, D'Angelo T, Bodelle B, Vogl TJ, Scholtz JE.

Eur J Radiol. 2018 Feb;99:111-117. doi: 10.1016/j.ejrad.2017.12.024. Epub 2017 Dec 30.

PMID:
29362140
38.

Tailored carbon partitioning for phototrophic production of (E)-α-bisabolene from the green microalga Chlamydomonas reinhardtii.

Wichmann J, Baier T, Wentnagel E, Lauersen KJ, Kruse O.

Metab Eng. 2018 Jan;45:211-222. doi: 10.1016/j.ymben.2017.12.010. Epub 2017 Dec 16.

PMID:
29258965
39.

Impact of T-cell-mediated immune response on xenogeneic heart valve transplantation: short-term success and mid-term failure.

Biermann AC, Marzi J, Brauchle E, Schneider M, Kornberger A, Abdelaziz S, Wichmann JL, Arendt CT, Nagel E, Brockbank KGM, Seifert M, Schenke-Layland K, Stock UA.

Eur J Cardiothorac Surg. 2018 Apr 1;53(4):784-792. doi: 10.1093/ejcts/ezx396.

40.

Impact of noise-optimized virtual monoenergetic dual-energy computed tomography on image quality in patients with renal cell carcinoma.

Martin SS, Wichmann JL, Pfeifer S, Leithner D, Lenga L, Reynolds MA, D'Angelo T, Hammerstingl R, Gruber-Rouh T, Vogl TJ, Albrecht MH.

Eur J Radiol. 2017 Dec;97:1-7. doi: 10.1016/j.ejrad.2017.10.008. Epub 2017 Oct 6.

PMID:
29153358
41.

High-pitch dual-source paranasal sinus CT in agitated patients with maxillofacial trauma: analysis of image quality, motion artifacts, and dose aspects.

Frellesen C, Wichmann JL, Tischendorf P, Scholtz JE, Beeres M, Vogl TJ, Bauer RW.

Acta Radiol. 2018 Aug;59(8):909-916. doi: 10.1177/0284185117740931. Epub 2017 Nov 6.

PMID:
29105487
42.

Acute kidney injury in patients with nephrotic syndrome undergoing contrast-enhanced CT for suspected venous thromboembolism: a propensity score-matched retrospective cohort study.

Tao SM, Kong X, Schoepf UJ, Wichmann JL, Shuler DC, Zhou CS, Lu GM, Zhang LJ.

Eur Radiol. 2018 Apr;28(4):1585-1593. doi: 10.1007/s00330-017-5109-0. Epub 2017 Nov 2.

PMID:
29098438
43.

Optimisation of window settings for traditional and noise-optimised virtual monoenergetic imaging in dual-energy computed tomography pulmonary angiography.

D'Angelo T, Bucher AM, Lenga L, Arendt CT, Peterke JL, Caruso D, Mazziotti S, Blandino A, Ascenti G, Othman AE, Martin SS, Leithner D, Vogl TJ, Wichmann JL.

Eur Radiol. 2018 Apr;28(4):1393-1401. doi: 10.1007/s00330-017-5059-6. Epub 2017 Oct 10.

PMID:
29018926
44.

Iodine and Fat Quantification for Differentiation of Adrenal Gland Adenomas From Metastases Using Third-Generation Dual-Source Dual-Energy Computed Tomography.

Martin SS, Weidinger S, Czwikla R, Kaltenbach B, Albrecht MH, Lenga L, Vogl TJ, Wichmann JL.

Invest Radiol. 2018 Mar;53(3):173-178. doi: 10.1097/RLI.0000000000000425.

PMID:
28990974
45.

Dual-energy computed tomography in patients with cutaneous malignant melanoma: Comparison of noise-optimized and traditional virtual monoenergetic imaging.

Martin SS, Wichmann JL, Weyer H, Albrecht MH, D'Angelo T, Leithner D, Lenga L, Booz C, Scholtz JE, Bodelle B, Vogl TJ, Hammerstingl R.

Eur J Radiol. 2017 Oct;95:1-8. doi: 10.1016/j.ejrad.2017.07.017. Epub 2017 Jul 21.

PMID:
28987652
46.

Long-range transport clusters and positive matrix factorization source apportionment for investigating transboundary PM2.5 in Gothenburg, Sweden.

Molnár P, Tang L, Sjöberg K, Wichmann J.

Environ Sci Process Impacts. 2017 Oct 18;19(10):1270-1277. doi: 10.1039/c7em00122c.

PMID:
28799617
47.

Evaluation of microwave ablation of liver malignancy with enabled constant spatial energy control to achieve a predictable spherical ablation zone.

Vogl TJ, Basten LM, Nour-Eldin NA, Kaltenbach B, Bodelle B, Wichmann JL, Ackermann H, Naguib NNN.

Int J Hyperthermia. 2018 Jun;34(4):492-500. doi: 10.1080/02656736.2017.1358408. Epub 2017 Aug 3.

PMID:
28774210
48.

A comparative study on the activity of fungal lytic polysaccharide monooxygenases for the depolymerization of cellulose in soybean spent flakes.

Pierce BC, Agger JW, Zhang Z, Wichmann J, Meyer AS.

Carbohydr Res. 2017 Sep 8;449:85-94. doi: 10.1016/j.carres.2017.07.004. Epub 2017 Jul 18.

PMID:
28750348
49.

Noise-Optimized Virtual Monoenergetic Dual-Energy CT Improves Diagnostic Accuracy for the Detection of Active Arterial Bleeding of the Abdomen.

Martin SS, Wichmann JL, Scholtz JE, Leithner D, D'Angelo T, Weyer H, Booz C, Lenga L, Vogl TJ, Albrecht MH.

J Vasc Interv Radiol. 2017 Sep;28(9):1257-1266. doi: 10.1016/j.jvir.2017.06.011. Epub 2017 Jul 19.

PMID:
28734847
50.

Endoleaks after endovascular aortic aneurysm repair: Improved detection with noise-optimized virtual monoenergetic dual-energy CT.

Martin SS, Wichmann JL, Weyer H, Scholtz JE, Leithner D, Spandorfer A, Bodelle B, Jacobi V, Vogl TJ, Albrecht MH.

Eur J Radiol. 2017 Sep;94:125-132. doi: 10.1016/j.ejrad.2017.06.017. Epub 2017 Jun 27.

PMID:
28712695

Supplemental Content

Loading ...
Support Center