Format
Sort by
Items per page

Send to

Choose Destination

Search results

Items: 1 to 50 of 193

1.

Intraneural sensory feedback restores grip force control and motor coordination while using a prosthetic hand.

Clemente F, Valle G, Controzzi M, Strauss I, Iberite F, Stieglitz T, Granata G, Rossini PM, Petrini FM, Micera S, Cipriani C.

J Neural Eng. 2019 Feb 8. doi: 10.1088/1741-2552/ab059b. [Epub ahead of print]

PMID:
30736030
2.

Long-Term Functionality of Transversal Intraneural Electrodes Is Improved By Dexamethasone Treatment.

de la Oliva N, Del Valle J, Delgado-Martinez I, Mueller M, Stieglitz T, Navarro X.

IEEE Trans Neural Syst Rehabil Eng. 2019 Feb 4. doi: 10.1109/TNSRE.2019.2897256. [Epub ahead of print]

PMID:
30716042
3.

A Novel Approach To Quantify Air-Water Gas Exchange in Shallow Surface Waters Using High-Resolution Time Series of Dissolved Atmospheric Gases.

Weber UW, Cook PG, Brennwald MS, Kipfer R, Stieglitz TC.

Environ Sci Technol. 2019 Feb 5;53(3):1463-1470. doi: 10.1021/acs.est.8b05318. Epub 2019 Jan 14.

PMID:
30576112
4.

Glassy Carbon Electrocorticography Electrodes on Ultra-Thin and Finger-Like Polyimide Substrate: Performance Evaluation Based on Different Electrode Diameters.

Vomero M, Zucchini E, Delfino E, Gueli C, Mondragon NC, Carli S, Fadiga L, Stieglitz T.

Materials (Basel). 2018 Dec 7;11(12). pii: E2486. doi: 10.3390/ma11122486.

5.

Six-Month Assessment of a Hand Prosthesis with Intraneural Tactile Feedback.

Petrini FM, Valle G, Strauss I, Granata G, Di Iorio R, D'Anna E, Čvančara P, Mueller M, Carpaneto J, Clemente F, Controzzi M, Bisoni L, Carboni C, Barbaro M, Iodice F, Andreu D, Hiairrassary A, Divoux JL, Cipriani C, Guiraud D, Raffo L, Fernandez E, Stieglitz T, Raspopovic S, Rossini PM, Micera S.

Ann Neurol. 2019 Jan;85(1):137-154. doi: 10.1002/ana.25384. Epub 2018 Dec 24.

PMID:
30474259
6.

In Situ Measurement of Stimulus Induced pH Changes Using ThinFilm Embedded IrOx pH Electrodes.

Pfau J, Leal Ordonez JA, Stieglitz T.

Conf Proc IEEE Eng Med Biol Soc. 2018 Jul;2018:5049-5052. doi: 10.1109/EMBC.2018.8513441.

PMID:
30441475
7.

Implantable Glass Waveguides and Coating Materials for Chronic Optical Medical Applications.

Alt MT, Mittnacht A, Stieglitz T.

Conf Proc IEEE Eng Med Biol Soc. 2018 Jul;2018:4595-4598. doi: 10.1109/EMBC.2018.8513121.

PMID:
30441375
8.

Micro-folded 3D neural electrodes fully integrated in polyimide.

Rehberger F, Stieglitz T, Eickenscheidt M.

Conf Proc IEEE Eng Med Biol Soc. 2018 Jul;2018:4587-4590. doi: 10.1109/EMBC.2018.8513144.

PMID:
30441373
9.

Achieving Ultra-Conformability With Polyimide-Based ECoG Arrays.

Vomero M, Cruz MFP, Zucchini E, Shabanian A, Delfino E, Carli S, Fadiga L, Ricci D, Stieglitz T.

Conf Proc IEEE Eng Med Biol Soc. 2018 Jul;2018:4464-4467. doi: 10.1109/EMBC.2018.8513171.

PMID:
30441342
10.

Neurophysiological Evaluation of a Customizable μECoG-based Wireless Brain Implant.

Gkogkidis CA, Bentler C, Wang X, Gierthmuehlen M, Scheiwe C, Schmitz HC, Haberstroh J, Stieglitz T, Ball T.

Conf Proc IEEE Eng Med Biol Soc. 2018 Jul;2018:2953-2956. doi: 10.1109/EMBC.2018.8513044.

PMID:
30441019
11.

PDMS Gasket Underfill for Long-Term Insulation of High-Density Interconnections in Active Implantable Medical Devices.

Khan S, Scholz D, Ordonez JS, Stieglitz T.

Conf Proc IEEE Eng Med Biol Soc. 2018 Jul;2018:2941-2944. doi: 10.1109/EMBC.2018.8512884.

PMID:
30441017
12.

Low temperature approach for high density electrical feedthroughs for neural implants using maskless fabrication techniques.

Langenmair M, Martens J, Gierthmuehlen M, Plachta DTT, Stieglitz T.

Conf Proc IEEE Eng Med Biol Soc. 2018 Jul;2018:2933-2936. doi: 10.1109/EMBC.2018.8512922.

PMID:
30441015
13.

Integrity Assessment of a Hybrid DBS Probe that Enables Neurotransmitter Detection Simultaneously to Electrical Stimulation and Recording.

Ashouri Vajari D, Vomero M, Erhardt JB, Sadr A, Ordonez JS, Coenen VA, Stieglitz T.

Micromachines (Basel). 2018 Oct 10;9(10). pii: E510. doi: 10.3390/mi9100510.

14.

Comparison of linear frequency and amplitude modulation for intraneural sensory feedback in bidirectional hand prostheses.

Valle G, Petrini FM, Strauss I, Iberite F, D'Anna E, Granata G, Controzzi M, Cipriani C, Stieglitz T, Rossini PM, Mazzoni A, Raspopovic S, Micera S.

Sci Rep. 2018 Nov 12;8(1):16666. doi: 10.1038/s41598-018-34910-w.

15.

Synchrony surfacing: Epicortical recording of correlated action potentials.

Bockhorst T, Pieper F, Engler G, Stieglitz T, Galindo-Leon E, Engel AK.

Eur J Neurosci. 2018 Dec;48(12):3583-3596. doi: 10.1111/ejn.14167. Epub 2018 Oct 22.

PMID:
30345590
16.

Graphitic Carbon Electrodes on Flexible Substrate for Neural Applications Entirely Fabricated Using Infrared Nanosecond Laser Technology.

Vomero M, Oliveira A, Ashouri D, Eickenscheidt M, Stieglitz T.

Sci Rep. 2018 Oct 3;8(1):14749. doi: 10.1038/s41598-018-33083-w.

17.

Biomimetic Intraneural Sensory Feedback Enhances Sensation Naturalness, Tactile Sensitivity, and Manual Dexterity in a Bidirectional Prosthesis.

Valle G, Mazzoni A, Iberite F, D'Anna E, Strauss I, Granata G, Controzzi M, Clemente F, Rognini G, Cipriani C, Stieglitz T, Petrini FM, Rossini PM, Micera S.

Neuron. 2018 Oct 10;100(1):37-45.e7. doi: 10.1016/j.neuron.2018.08.033. Epub 2018 Sep 20.

PMID:
30244887
18.

Multisensory bionic limb to achieve prosthesis embodiment and reduce distorted phantom limb perceptions.

Rognini G, Petrini FM, Raspopovic S, Valle G, Granata G, Strauss I, Solcà M, Bello-Ruiz J, Herbelin B, Mange R, D'Anna E, Di Iorio R, Di Pino G, Andreu D, Guiraud D, Stieglitz T, Rossini PM, Serino A, Micera S, Blanke O.

J Neurol Neurosurg Psychiatry. 2018 Aug 12. pii: jnnp-2018-318570. doi: 10.1136/jnnp-2018-318570. [Epub ahead of print] No abstract available.

PMID:
30100550
19.

Groundwater-driven nutrient inputs to coastal lagoons: The relevance of lagoon water recirculation as a conveyor of dissolved nutrients.

Rodellas V, Stieglitz TC, Andrisoa A, Cook PG, Raimbault P, Tamborski JJ, van Beek P, Radakovitch O.

Sci Total Environ. 2018 Nov 15;642:764-780. doi: 10.1016/j.scitotenv.2018.06.095. Epub 2018 Jun 17.

PMID:
29920463
20.

On the use of Parylene C polymer as substrate for peripheral nerve electrodes.

de la Oliva N, Mueller M, Stieglitz T, Navarro X, Del Valle J.

Sci Rep. 2018 Apr 13;8(1):5965. doi: 10.1038/s41598-018-24502-z.

21.

Phantom somatosensory evoked potentials following selective intraneural electrical stimulation in two amputees.

Granata G, Di Iorio R, Romanello R, Iodice F, Raspopovic S, Petrini F, Strauss I, Valle G, Stieglitz T, Čvančara P, Andreu D, Divoux JL, Guiraud D, Wauters L, Hiairrassary A, Jensen W, Micera S, Rossini PM.

Clin Neurophysiol. 2018 Jun;129(6):1117-1120. doi: 10.1016/j.clinph.2018.02.138. Epub 2018 Mar 26.

PMID:
29625342
22.

Should patients with brain implants undergo MRI?

Erhardt JB, Fuhrer E, Gruschke OG, Leupold J, Wapler MC, Hennig J, Stieglitz T, Korvink JG.

J Neural Eng. 2018 Aug;15(4):041002. doi: 10.1088/1741-2552/aab4e4. Epub 2018 Mar 7.

PMID:
29513262
23.

Integrated optoelectronic microprobes.

Rudmann L, Alt MT, Ashouri Vajari D, Stieglitz T.

Curr Opin Neurobiol. 2018 Jun;50:72-82. doi: 10.1016/j.conb.2018.01.010. Epub 2018 Feb 4. Review.

PMID:
29414738
24.

Paradigms for restoration of somatosensory feedback via stimulation of the peripheral nervous system.

Pasluosta C, Kiele P, Stieglitz T.

Clin Neurophysiol. 2018 Apr;129(4):851-862. doi: 10.1016/j.clinph.2017.12.027. Epub 2017 Dec 27. Review.

PMID:
29343415
25.

A single channel sleep-spindle detector based on multivariate classification of EEG epochs: MUSSDET.

Lachner-Piza D, Epitashvili N, Schulze-Bonhage A, Stieglitz T, Jacobs J, Dümpelmann M.

J Neurosci Methods. 2018 Mar 1;297:31-43. doi: 10.1016/j.jneumeth.2017.12.023. Epub 2017 Dec 29.

PMID:
29291925
26.

A 64-channels neural interface for biopotentials recording and PNS stimulation.

Bisoni L, Carboni C, Puddu R, Barabino G, Pani D, Raffo L, Mueller M, Stieglitz T, Del Valle J, de la Oliva N, Delgado-Martinez I, Navarro X, Barbaro M.

Conf Proc IEEE Eng Med Biol Soc. 2017 Jul;2017:1938-1941. doi: 10.1109/EMBC.2017.8037228.

PMID:
29060272
27.

Building wireless implantable neural interfaces within weeks for neuroscientists.

Bentler C, Stieglitz T.

Conf Proc IEEE Eng Med Biol Soc. 2017 Jul;2017:1078-1081. doi: 10.1109/EMBC.2017.8037014.

PMID:
29060061
28.

Design of experiment evaluation of sputtered thin film platinum surface metallization on alumina substrate for implantable conductive structures.

Kiele P, Cvancara P, Mueller M, Stieglitz T.

Conf Proc IEEE Eng Med Biol Soc. 2017 Jul;2017:1066-1069. doi: 10.1109/EMBC.2017.8037011.

PMID:
29060058
29.

Nanostructured platinum as an electrochemically and mechanically stable electrode coating.

Boehler C, Oberueber F, Stieglitz T, Asplund M.

Conf Proc IEEE Eng Med Biol Soc. 2017 Jul;2017:1058-1061. doi: 10.1109/EMBC.2017.8037009.

PMID:
29060056
30.

Precise localization of silicone-based intercranial planar electrodes in magnetic resonance imaging.

Erhardt JB, Koenig K, Leupold J, Pasluosta C, Stieglitz T.

Conf Proc IEEE Eng Med Biol Soc. 2017 Jul;2017:513-516. doi: 10.1109/EMBC.2017.8036874.

PMID:
29059922
31.

Design of contact zone topography for implantable high-channel electrical connectors.

Koch J, Schuettler M, Stieglitz T.

Conf Proc IEEE Eng Med Biol Soc. 2017 Jul;2017:238-241. doi: 10.1109/EMBC.2017.8036806.

PMID:
29059854
32.

Dynamic reconfiguration of cortical functional connectivity across brain states.

Stitt I, Hollensteiner KJ, Galindo-Leon E, Pieper F, Fiedler E, Stieglitz T, Engler G, Nolte G, Engel AK.

Sci Rep. 2017 Aug 18;7(1):8797. doi: 10.1038/s41598-017-08050-6.

33.

Return of the cadaver: Key role of anatomic dissection for plastic surgery resident training.

Krähenbühl SM, Čvančara P, Stieglitz T, Bonvin R, Michetti M, Flahaut M, Durand S, Deghayli L, Applegate LA, Raffoul W.

Medicine (Baltimore). 2017 Jul;96(29):e7528. doi: 10.1097/MD.0000000000007528.

34.

Rapid prototyping of flexible intrafascicular electrode arrays by picosecond laser structuring.

Mueller M, de la Oliva N, Del Valle J, Delgado-Martínez I, Navarro X, Stieglitz T.

J Neural Eng. 2017 Dec;14(6):066016. doi: 10.1088/1741-2552/aa7eea.

PMID:
28695839
35.

How to record high-frequency oscillations in epilepsy: A practical guideline.

Zijlmans M, Worrell GA, Dümpelmann M, Stieglitz T, Barborica A, Heers M, Ikeda A, Usui N, Le Van Quyen M.

Epilepsia. 2017 Aug;58(8):1305-1315. doi: 10.1111/epi.13814. Epub 2017 Jun 16. Review.

36.

Mapping the fine structure of cortical activity with different micro-ECoG electrode array geometries.

Wang X, Gkogkidis CA, Iljina O, Fiederer LDJ, Henle C, Mader I, Kaminsky J, Stieglitz T, Gierthmuehlen M, Ball T.

J Neural Eng. 2017 Oct;14(5):056004. doi: 10.1088/1741-2552/aa785e. Epub 2017 Jun 9.

PMID:
28597847
37.

Actively controlled release of Dexamethasone from neural microelectrodes in a chronic in vivo study.

Boehler C, Kleber C, Martini N, Xie Y, Dryg I, Stieglitz T, Hofmann UG, Asplund M.

Biomaterials. 2017 Jun;129:176-187. doi: 10.1016/j.biomaterials.2017.03.019. Epub 2017 Mar 13.

38.

In vivo characterization of a versatile 8-channel digital biopotential recording system with sub-μVRMS input noise.

Cota OF, Plachta D, Stieglitz T, Kundumattathil S, Manoli Y, Kuhl M.

Conf Proc IEEE Eng Med Biol Soc. 2016 Aug;2016:6311-6314. doi: 10.1109/EMBC.2016.7592171.

PMID:
28269692
39.

Differentiation of spindle associated hippocampal HFOs based on a correlation analysis.

Piza DL, Bruder JC, Jacobs J, Schulze-Bonhage A, Stieglitz T, Dumpelmann M.

Conf Proc IEEE Eng Med Biol Soc. 2016 Aug;2016:5501-5504. doi: 10.1109/EMBC.2016.7591972.

PMID:
28269503
40.

A double-sided fabrication process for intrafascicular parylene C based electrode arrays.

Mueller M, Boehler C, Jaeger J, Asplund M, Stieglitz T.

Conf Proc IEEE Eng Med Biol Soc. 2016 Aug;2016:2798-2801. doi: 10.1109/EMBC.2016.7591311.

PMID:
28268899
41.

Investigation on the hermeticity of an implantable package with 32 feedthroughs for neural prosthetic applications.

Bisoni L, Mueller M, Cvancara P, Carboni C, Puddu R, Raffo L, Barbaro M, Stieglitz T.

Conf Proc IEEE Eng Med Biol Soc. 2016 Aug;2016:1967-1970. doi: 10.1109/EMBC.2016.7591109.

PMID:
28268714
42.

Investigations on different epoxies for electrical insulation of microflex structures.

Cvancara P, Lauser S, Rudmann L, Stieglitz T.

Conf Proc IEEE Eng Med Biol Soc. 2016 Aug;2016:1963-1966. doi: 10.1109/EMBC.2016.7591108.

PMID:
28268713
43.

Epoxy casting used as nonhermetic encapsulation technique for implantable electronic devices.

Boeser F, Lang BG, Stieglitz T, Plachta DT.

Conf Proc IEEE Eng Med Biol Soc. 2016 Aug;2016:1938-1941. doi: 10.1109/EMBC.2016.7591102.

PMID:
28268707
44.

Simulation of effects of the electrode structure and material in the density measuring system of the peripheral nerve based on micro-electrical impedance tomography.

Behkami S, Frounchi J, Ghaderi Pakdel F, Stieglitz T.

Biomed Tech (Berl). 2018 Mar 28;63(2):151-161. doi: 10.1515/bmt-2016-0089.

PMID:
28076294
45.

Concept and Development of an Electronic Framework Intended for Electrode and Surrounding Environment Characterization In Vivo.

Rieger SB, Pfau J, Stieglitz T, Asplund M, Ordonez JS.

Sensors (Basel). 2016 Dec 30;17(1). pii: E59. doi: 10.3390/s17010059.

46.

Laser-Induced Carbon Pyrolysis of Electrodes for Neural Interface Systems.

Oliveira A, Ordonez JS, Vajari DA, Eickenscheidt M, Stieglitz T.

Eur J Transl Myol. 2016 Jun 13;26(3):6062. eCollection 2016 Jun 13.

47.

Long-Term Stable Adhesion for Conducting Polymers in Biomedical Applications: IrOx and Nanostructured Platinum Solve the Chronic Challenge.

Boehler C, Oberueber F, Schlabach S, Stieglitz T, Asplund M.

ACS Appl Mater Interfaces. 2017 Jan 11;9(1):189-197. doi: 10.1021/acsami.6b13468. Epub 2016 Dec 22.

48.

Influence of Anatomical Detail and Tissue Conductivity Variations in Simulations of Multi-Contact Nerve Cuff Recordings.

Garai P, Koh RGL, Schuettler M, Stieglitz T, Zariffa J.

IEEE Trans Neural Syst Rehabil Eng. 2017 Sep;25(9):1653-1662. doi: 10.1109/TNSRE.2016.2633005. Epub 2016 Nov 24.

PMID:
27898383
49.

Track U. BrainLinks-BrainTools-Methods and tools for neural engineering.

Stieglitz T, Paul O, Wallrabe U, Ruther P.

Biomed Tech (Berl). 2016 Sep 1;61(s1):234-243. doi: 10.1515/bmt-2016-5019. No abstract available.

PMID:
27682701
50.

Intracortical polyimide electrodes with a bioresorbable coating.

Hassler C, Guy J, Nietzschmann M, Plachta DT, Staiger JF, Stieglitz T.

Biomed Microdevices. 2016 Oct;18(5):81. doi: 10.1007/s10544-016-0106-7.

PMID:
27534649

Supplemental Content

Loading ...
Support Center