Environ Monit Assess. 2006 Mar;114(1-3):199-209. Epub 2006 Feb 15.

Calibration and validation of far field dilution models for outfall at Worli, Mumbai.

Author information

1
National Environmental Engineering Research Institute, Worli, Mumbai, India. neerimumbai@mtnl.net.in

Abstract

The city of Mumbai, India with a population of 15 million discharges about 2225 MLD of domestic wastewater after partial treatment to adjoining marine water body. Under the Mumbai Sewage Disposal Project Scheme, sewage is being disposed to the west coast at Worli and Bandra through 3.4 kms long submarine outfalls. A field study was conducted at recently commissioned outfall diffuser location at Worli, at the onset of neap flood tide to study the dispersion patterns and measure the far field dilutions using radio and dye tracers. Estimated dilutions using different tracers were compared with outputs from an empirical model (Brooks) and a 2D numerical model (DIVAST). Validation using parameters such as BOD and FC, indicated a good match for BOD in near field compared to FC. The radiotracer (82)Br and Rhodamine WT generally gave good correlation with Brooks' and DIVAST models for nearfield, however at further distances predictions were not accurate.