Format
Sort by
Items per page

Send to

Choose Destination

Search results

Items: 29

1.

Is the synovial fluid cobalt-to-chromium ratio related to the serum partitioning of metal debris following metal-on-metal hip arthroplasty?

Langton DJ, Natu S, Harrington CF, Bowsher JG, Nargol AVF.

Bone Joint Res. 2019 Apr 2;8(3):146-155. doi: 10.1302/2046-3758.83.BJR-2018-0049.R1. eCollection 2019 Mar.

2.

Material loss at the femoral head taper: a comparison study of the Exeter metal-on-polyethylene and contemporary metal-on-metal total hip arthroplasty.

Langton DJ, Wells SR, Joyce TJ, Bowsher JG, Deehan D, Green S, Nargol AVF, Holland JP.

Bone Joint J. 2018 Oct;100-B(10):1310-1319. doi: 10.1302/0301-620X.100B10.BJJ-2017-0406.R3.

PMID:
30295525
3.

Aseptic lymphocyte-dominated vasculitis-associated lesions are related to changes in metal ion handling in the joint capsules of metal-on-metal hip arthroplasties.

Langton DJ, Sidaginamale RP, Joyce TJ, Bowsher JG, Holland JP, Deehan D, Nargol AVF, Natu S.

Bone Joint Res. 2018 Jul 7;7(6):388-396. doi: 10.1302/2046-3758.76.BJR-2018-0037. eCollection 2018 Jun.

4.

A comparison study of stem taper material loss at similar and mixed metal head-neck taper junctions.

Langton DJ, Sidaginamale RP, Joyce TJ, Meek RD, Bowsher JG, Deehan D, Nargol AVF, Holland JP.

Bone Joint J. 2017 Oct;99-B(10):1304-1312. doi: 10.1302/0301-620X.99B10.BJJ-2016-1005.R1.

PMID:
28963151
5.

Investigation of Taper Failure in a Contemporary Metal-on-Metal Hip Arthroplasty System Through Examination of Unused and Explanted Prostheses.

Langton D, Ahmed I, Avery P, Bone M, Cooke N, Deehan D, Duffy P, Foguet P, Green S, Holland J, Jafri A, Longstaff L, Lord J, Loughead J, Meek RM, Murray H, Nanu A, Nargol AV, Scholes SC, Sidaginamale RP, Waller S, Joyce T.

J Bone Joint Surg Am. 2017 Mar 1;99(5):427-436. doi: 10.2106/JBJS.15.00917.

PMID:
28244914
6.

The clinical implications of metal debris release from the taper junctions and bearing surfaces of metal-on-metal hip arthroplasty: joint fluid and blood metal ion concentrations.

Sidaginamale RP, Joyce TJ, Bowsher JG, Lord JK, Avery PJ, Natu S, Nargol AV, Langton DJ.

Bone Joint J. 2016 Jul;98-B(7):925-33. doi: 10.1302/0301-620X.98B7.37029.

PMID:
27365470
7.

Retrospective cohort study of the performance of the Pinnacle metal on metal (MoM) total hip replacement: a single-centre investigation in combination with the findings of a national retrieval centre.

Langton DJ, Sidaginamale RP, Avery P, Waller S, Tank G, Lord J, Joyce T, Cooke N, Logishetty R, Nargol AV.

BMJ Open. 2016 Apr 29;6(4):e007847. doi: 10.1136/bmjopen-2015-007847.

8.

The Tribology of Explanted Hip Resurfacings Following Early Fracture of the Femur.

Lord JK, Langton DJ, Nargol AV, Meek RM, Joyce TJ.

J Funct Biomater. 2015 Oct 15;6(4):1021-35. doi: 10.3390/jfb6041021.

9.

Shorter, rough trunnion surfaces are associated with higher taper wear rates than longer, smooth trunnion surfaces in a contemporary large head metal-on-metal total hip arthroplasty system.

Brock TM, Sidaginamale R, Rushton S, Nargol AV, Bowsher JG, Savisaar C, Joyce TJ, Deehan DJ, Lord JK, Langton DJ.

J Orthop Res. 2015 Dec;33(12):1868-74. doi: 10.1002/jor.22970. Epub 2015 Jul 25.

10.

Determining material loss from the femoral stem trunnion in hip arthroplasty using a coordinate measuring machine.

Bone MC, Sidaginamale RP, Lord JK, Scholes SC, Joyce TJ, Nargol AV, Langton DJ.

Proc Inst Mech Eng H. 2015 Jan;229(1):69-76. doi: 10.1177/0954411914567552.

PMID:
25655956
11.

Practical considerations for volumetric wear analysis of explanted hip arthroplasties.

Langton DJ, Sidaginamale RP, Holland JP, Deehan D, Joyce TJ, Nargol AV, Meek RD, Lord JK.

Bone Joint Res. 2014 Mar 13;3(3):60-8. doi: 10.1302/2046-3758.33.2000249. Print 2014.

12.

Blood metal ion testing is an effectivescreening tool to identify poorly performing metal-on-metal bearingsurfaces.

Sidaginamale RP, Joyce TJ, Lord JK, Jefferson R, Blain PG, Nargol AV, Langton DJ.

Bone Joint Res. 2013 May 16;2(5):84-95. doi: 10.1302/2046-3758.25.2000148. Print 2013.

13.

Taper junction failure in large-diameter metal-on-metal bearings.

Langton DJ, Sidaginamale R, Lord JK, Nargol AV, Joyce TJ.

Bone Joint Res. 2012 Apr 1;1(4):56-63. doi: 10.1302/2046-3758.14.2000047. Print 2012 Apr.

14.

The clinical implications of elevated blood metal ion concentrations in asymptomatic patients with MoM hip resurfacings: a cohort study.

Langton DJ, Sidaginamale RP, Joyce TJ, Natu S, Blain P, Jefferson RD, Rushton S, Nargol AV.

BMJ Open. 2013 Mar 12;3(3). pii: e001541. doi: 10.1136/bmjopen-2012-001541.

15.

Adverse reactions to metal debris: histopathological features of periprosthetic soft tissue reactions seen in association with failed metal on metal hip arthroplasties.

Natu S, Sidaginamale RP, Gandhi J, Langton DJ, Nargol AV.

J Clin Pathol. 2012 May;65(5):409-18. doi: 10.1136/jclinpath-2011-200398. Epub 2012 Mar 15.

PMID:
22422805
16.

Accelerating failure rate of the ASR total hip replacement.

Langton DJ, Jameson SS, Joyce TJ, Gandhi JN, Sidaginamale R, Mereddy P, Lord J, Nargol AV.

J Bone Joint Surg Br. 2011 Aug;93(8):1011-6. doi: 10.1302/0301-620X.93B8.26040.

PMID:
21768621
17.

Metal-on-metal bearings: the evidence so far.

Haddad FS, Thakrar RR, Hart AJ, Skinner JA, Nargol AV, Nolan JF, Gill HS, Murray DW, Blom AW, Case CP.

J Bone Joint Surg Br. 2011 May;93(5):572-9. doi: 10.1302/0301-620X.93B4.26429. Review.

PMID:
21511920
18.

Reducing metal ion release following hip resurfacing arthroplasty.

Langton DJ, Joyce TJ, Mangat N, Lord J, Van Orsouw M, De Smet K, Nargol AV.

Orthop Clin North Am. 2011 Apr;42(2):169-80, viii. doi: 10.1016/j.ocl.2011.01.006.

PMID:
21435493
19.

Adverse reaction to metal debris following hip resurfacing: the influence of component type, orientation and volumetric wear.

Langton DJ, Joyce TJ, Jameson SS, Lord J, Van Orsouw M, Holland JP, Nargol AV, De Smet KA.

J Bone Joint Surg Br. 2011 Feb;93(2):164-71. doi: 10.1302/0301-620X.93B2.25099. Erratum in: J Bone Joint Surg Br. 2011 Apr;93(4):566.

PMID:
21282753
20.

EMG analysis of lumbar paraspinal muscles as a predictor of the risk of low-back pain.

Heydari A, Nargol AV, Jones AP, Humphrey AR, Greenough CG.

Eur Spine J. 2010 Jul;19(7):1145-52. doi: 10.1007/s00586-010-1277-1. Epub 2010 Feb 2.

21.

Early failure of metal-on-metal bearings in hip resurfacing and large-diameter total hip replacement: A consequence of excess wear.

Langton DJ, Jameson SS, Joyce TJ, Hallab NJ, Natu S, Nargol AV.

J Bone Joint Surg Br. 2010 Jan;92(1):38-46. doi: 10.1302/0301-620X.92B1.22770.

PMID:
20044676
22.

Articular surface replacement of the hip: a prospective single-surgeon series.

Jameson SS, Langton DJ, Nargol AV.

J Bone Joint Surg Br. 2010 Jan;92(1):28-37. doi: 10.1302/0301-620X.92B1.22769.

PMID:
20044675
23.

Cup anteversion in hip resurfacing: validation of EBRA and the presentation of a simple clinical grading system.

Langton DJ, Sprowson AP, Mahadeva D, Bhatnagar S, Holland JP, Nargol AV.

J Arthroplasty. 2010 Jun;25(4):607-13. doi: 10.1016/j.arth.2009.08.020. Epub 2009 Dec 21.

PMID:
20022454
24.

Blood metal ion concentrations after hip resurfacing arthroplasty: a comparative study of articular surface replacement and Birmingham Hip Resurfacing arthroplasties.

Langton DJ, Sprowson AP, Joyce TJ, Reed M, Carluke I, Partington P, Nargol AV.

J Bone Joint Surg Br. 2009 Oct;91(10):1287-95. doi: 10.1302/0301-620X.91B10.22308.

PMID:
19794161
25.

The effect of component size and orientation on the concentrations of metal ions after resurfacing arthroplasty of the hip.

Langton DJ, Jameson SS, Joyce TJ, Webb J, Nargol AV.

J Bone Joint Surg Br. 2008 Sep;90(9):1143-51. doi: 10.1302/0301-620X.90B9.20785.

PMID:
18757952
26.

The value of electromyography of the lumbar paraspinal muscles in discriminating between chronic-low-back-pain sufferers and normal subjects.

Humphrey AR, Nargol AV, Jones AP, Ratcliffe AA, Greenough CG.

Eur Spine J. 2005 Mar;14(2):175-84. Epub 2004 Nov 12.

27.

Factors in the reproducibility of electromyographic power spectrum analysis of lumbar paraspinal muscle fatigue.

Nargol AV, Jones AP, Kelly PJ, Greenough CG.

Spine (Phila Pa 1976). 1999 May 1;24(9):883-8.

PMID:
10327510
28.

Pathological fractures of the proximal femur treated with the Variwall reconstruction nail.

Nargol AV, Port A, Seif-Asaad SS.

Injury. 1996 Jun;27(5):307-9.

PMID:
8763280
29.

Unstable intertrochanteric fractures treated with the Variwall reconstruction nail.

Seif-Asaad SS, Nargol AV, Port A.

Injury. 1995 Jul;26(6):367-72.

PMID:
7558255

Supplemental Content

Loading ...
Support Center