Format
Sort by
Items per page

Send to

Choose Destination

Search results

Items: 16

1.

Susceptibility Perturbation MRI Maps Tumor Infiltration into Mesorectal Lymph Nodes.

Santiago I, Santinha J, Ianus A, Galzerano A, Theias R, Maia J, Barata MJ, Loução N, Costa-Silva B, Beltran A, Matos C, Shemesh N.

Cancer Res. 2019 May 1;79(9):2435-2444. doi: 10.1158/0008-5472.CAN-18-3682. Epub 2019 Mar 20.

PMID:
30894376
2.

Effects of nongaussian diffusion on "isotropic diffusion" measurements: An ex-vivo microimaging and simulation study.

Jespersen SN, Olesen JL, Ianuş A, Shemesh N.

J Magn Reson. 2019 Mar;300:84-94. doi: 10.1016/j.jmr.2019.01.007. Epub 2019 Jan 21.

PMID:
30711786
3.

Layer-specific connectivity revealed by diffusion-weighted functional MRI in the rat thalamocortical pathway.

Nunes D, Ianus A, Shemesh N.

Neuroimage. 2019 Jan 1;184:646-657. doi: 10.1016/j.neuroimage.2018.09.050. Epub 2018 Sep 26.

4.

Relevance of time-dependence for clinically viable diffusion imaging of the spinal cord.

Grussu F, Ianuş A, Tur C, Prados F, Schneider T, Kaden E, Ourselin S, Drobnjak I, Zhang H, Alexander DC, Gandini Wheeler-Kingshott CAM.

Magn Reson Med. 2019 Feb;81(2):1247-1264. doi: 10.1002/mrm.27463. Epub 2018 Sep 5.

PMID:
30229564
5.

Accurate estimation of microscopic diffusion anisotropy and its time dependence in the mouse brain.

Ianuş A, Jespersen SN, Serradas Duarte T, Alexander DC, Drobnjak I, Shemesh N.

Neuroimage. 2018 Dec;183:934-949. doi: 10.1016/j.neuroimage.2018.08.034. Epub 2018 Aug 23.

PMID:
30145206
6.

An optimized framework for quantitative magnetization transfer imaging of the cervical spinal cord in vivo.

Battiston M, Grussu F, Ianus A, Schneider T, Prados F, Fairney J, Ourselin S, Alexander DC, Cercignani M, Gandini Wheeler-Kingshott CAM, Samson RS.

Magn Reson Med. 2018 May;79(5):2576-2588. doi: 10.1002/mrm.26909. Epub 2017 Sep 16.

7.

Neurite dispersion: a new marker of multiple sclerosis spinal cord pathology?

Grussu F, Schneider T, Tur C, Yates RL, Tachrount M, Ianuş A, Yiannakas MC, Newcombe J, Zhang H, Alexander DC, DeLuca GC, Gandini Wheeler-Kingshott CAM.

Ann Clin Transl Neurol. 2017 Aug 15;4(9):663-679. doi: 10.1002/acn3.445. eCollection 2017 Sep.

8.

Incomplete initial nutation diffusion imaging: An ultrafast, single-scan approach for diffusion mapping.

Ianuş A, Shemesh N.

Magn Reson Med. 2018 Apr;79(4):2198-2204. doi: 10.1002/mrm.26894. Epub 2017 Sep 3.

9.

Low frequency oscillating gradient spin-echo sequences improve sensitivity to axon diameter: An experimental study in viable nerve tissue.

Kakkar LS, Bennett OF, Siow B, Richardson S, Ianuş A, Quick T, Atkinson D, Phillips JB, Drobnjak I.

Neuroimage. 2018 Nov 15;182:314-328. doi: 10.1016/j.neuroimage.2017.07.060. Epub 2017 Aug 1.

10.

Double oscillating diffusion encoding and sensitivity to microscopic anisotropy.

Ianuş A, Shemesh N, Alexander DC, Drobnjak I.

Magn Reson Med. 2017 Aug;78(2):550-564. doi: 10.1002/mrm.26393. Epub 2016 Aug 31.

11.

Model-based estimation of microscopic anisotropy using diffusion MRI: a simulation study.

Ianuş A, Drobnjak I, Alexander DC.

NMR Biomed. 2016 May;29(5):672-85. doi: 10.1002/nbm.3496. Epub 2016 Mar 22.

PMID:
27003223
12.

Model-Based Estimation of Microscopic Anisotropy in Macroscopically Isotropic Substrates Using Diffusion MRI.

Ianuş A, Drobnjak I, Alexander DC.

Inf Process Med Imaging. 2015;24:699-710.

PMID:
26221714
13.

PGSE, OGSE, and sensitivity to axon diameter in diffusion MRI: Insight from a simulation study.

Drobnjak I, Zhang H, Ianuş A, Kaden E, Alexander DC.

Magn Reson Med. 2016 Feb;75(2):688-700. doi: 10.1002/mrm.25631. Epub 2015 Mar 25.

14.

Gaussian phase distribution approximations for oscillating gradient spin echo diffusion MRI.

Ianuş A, Siow B, Drobnjak I, Zhang H, Alexander DC.

J Magn Reson. 2013 Feb;227:25-34. doi: 10.1016/j.jmr.2012.11.021. Epub 2012 Nov 29.

PMID:
23261952
15.

Preoperative endoscopic airway examination (PEAE) provides superior airway information and may reduce the use of unnecessary awake intubation.

Rosenblatt W, Ianus AI, Sukhupragarn W, Fickenscher A, Sasaki C.

Anesth Analg. 2011 Mar;112(3):602-7. doi: 10.1213/ANE.0b013e3181fdfc1c. Epub 2010 Nov 16.

PMID:
21081768
16.

Supplemental Content

Support Center