Format
Sort by
Items per page

Send to

Choose Destination

Search results

Items: 1 to 50 of 266

1.

Imaging of the region of the osteochondral junction (OCJ) using a 3D adiabatic inversion recovery prepared ultrashort echo time cones (3D IR-UTE-cones) sequence at 3 T.

Ma YJ, Jerban S, Carl M, Wan L, Guo T, Jang H, Bydder GM, Chang EY, Du J.

NMR Biomed. 2019 May;32(5):e4080. doi: 10.1002/nbm.4080. Epub 2019 Feb 22.

PMID:
30794338
2.

Evaluation of normal cadaveric Achilles tendon and enthesis with ultrashort echo time (UTE) magnetic resonance imaging and indentation testing.

Chen B, Cheng X, Dorthe EW, Zhao Y, D'Lima D, Bydder GM, Liu S, Du J, Ma YJ.

NMR Biomed. 2019 Jan;32(1):e4034. doi: 10.1002/nbm.4034. Epub 2018 Nov 20.

3.

Accurate T1 mapping of short T2 tissues using a three-dimensional ultrashort echo time cones actual flip angle imaging-variable repetition time (3D UTE-Cones AFI-VTR) method.

Ma YJ, Lu X, Carl M, Zhu Y, Szeverenyi NM, Bydder GM, Chang EY, Du J.

Magn Reson Med. 2018 Aug;80(2):598-608. doi: 10.1002/mrm.27066. Epub 2018 Jan 3.

4.

Yet more evidence that myelin protons can be directly imaged with UTE sequences on a clinical 3T scanner: Bicomponent T2* analysis of native and deuterated ovine brain specimens.

Fan SJ, Ma Y, Zhu Y, Searleman A, Szeverenyi NM, Bydder GM, Du J.

Magn Reson Med. 2018 Aug;80(2):538-547. doi: 10.1002/mrm.27052. Epub 2017 Dec 21.

5.

Inversion recovery ultrashort echo time imaging of ultrashort T2 tissue components in ovine brain at 3 T: a sequential D2 O exchange study.

Fan SJ, Ma Y, Chang EY, Bydder GM, Du J.

NMR Biomed. 2017 Oct;30(10). doi: 10.1002/nbm.3767. Epub 2017 Jul 21.

6.

Effects of fat saturation on short T2 quantification.

Carl M, Nazaran A, Bydder GM, Du J.

Magn Reson Imaging. 2017 Nov;43:6-9. doi: 10.1016/j.mri.2017.06.007. Epub 2017 Jun 16.

PMID:
28629956
7.

Direct magnitude and phase imaging of myelin using ultrashort echo time (UTE) pulse sequences: A feasibility study.

He Q, Ma Y, Fan S, Shao H, Sheth V, Bydder GM, Du J.

Magn Reson Imaging. 2017 Jun;39:194-199. doi: 10.1016/j.mri.2017.02.009. Epub 2017 Feb 20.

8.

Inversion recovery ultrashort echo time magnetic resonance imaging: A method for simultaneous direct detection of myelin and high signal demonstration of iron deposition in the brain - A feasibility study.

Sheth VR, Fan S, He Q, Ma Y, Annese J, Switzer R, Corey-Bloom J, Bydder GM, Du J.

Magn Reson Imaging. 2017 May;38:87-94. doi: 10.1016/j.mri.2016.12.025. Epub 2016 Dec 28.

9.

Magnetic resonance imaging of myelin using ultrashort Echo time (UTE) pulse sequences: Phantom, specimen, volunteer and multiple sclerosis patient studies.

Sheth V, Shao H, Chen J, Vandenberg S, Corey-Bloom J, Bydder GM, Du J.

Neuroimage. 2016 Aug 1;136:37-44. doi: 10.1016/j.neuroimage.2016.05.012. Epub 2016 May 5.

11.

Thickness of the Meniscal Lamellar Layer: Correlation with Indentation Stiffness and Comparison of Normal and Abnormally Thick Layers by Using Multiparametric Ultrashort Echo Time MR Imaging.

Choi JY, Biswas R, Bae WC, Healey R, Im M, Statum S, Chang EY, Du J, Bydder GM, D'Lima D, Chung CB.

Radiology. 2016 Jul;280(1):161-8. doi: 10.1148/radiol.2016150633. Epub 2016 Feb 1.

12.

Evaluation of bound and pore water in cortical bone using ultrashort-TE MRI.

Chen J, Grogan SP, Shao H, D'Lima D, Bydder GM, Wu Z, Du J.

NMR Biomed. 2015 Dec;28(12):1754-1762. doi: 10.1002/nbm.3436. Epub 2015 Nov 3.

13.

High-Resolution Qualitative and Quantitative Magnetic Resonance Evaluation of the Glenoid Labrum.

Iwasaki K, Tafur M, Chang EY, Statum S, Biswas R, Tran B, Bae WC, Du J, Bydder GM, Chung CB.

J Comput Assist Tomogr. 2015 Nov-Dec;39(6):936-44. doi: 10.1097/RCT.0000000000000307.

14.

UTE imaging with simultaneous water and fat signal suppression using a time-efficient multispoke inversion recovery pulse sequence.

Carl M, Bydder GM, Du J.

Magn Reson Med. 2016 Aug;76(2):577-82. doi: 10.1002/mrm.25823. Epub 2015 Aug 26.

15.

Effects of inversion time on inversion recovery prepared ultrashort echo time (IR-UTE) imaging of bound and pore water in cortical bone.

Li S, Ma L, Chang EY, Shao H, Chen J, Chung CB, Bydder GM, Du J.

NMR Biomed. 2015 Jan;28(1):70-8. doi: 10.1002/nbm.3228. Epub 2014 Oct 28.

16.

Magnetic resonance imaging of the pulleys of the flexor tendons of the toes at 11.7 T.

Tafur M, Iwasaki K, Statum S, Chung CB, Szeverenyi NM, Bydder GM.

Skeletal Radiol. 2015 Jan;44(1):87-95. doi: 10.1007/s00256-014-2019-y. Epub 2014 Oct 2.

PMID:
25269752
17.

Measurement of T1 of the ultrashort T2* components in white matter of the brain at 3T.

Du J, Sheth V, He Q, Carl M, Chen J, Corey-Bloom J, Bydder GM.

PLoS One. 2014 Aug 5;9(8):e103296. doi: 10.1371/journal.pone.0103296. eCollection 2014.

18.
19.

Morphologic characterization of meniscal root ligaments in the human knee with magnetic resonance microscopy at 11.7 and 3 T.

Chang EY, Biswas R, DiCamillo P, Statum S, Tafur M, Bydder GM, Chung CB.

Skeletal Radiol. 2014 Oct;43(10):1395-402. doi: 10.1007/s00256-014-1941-3. Epub 2014 Jun 24.

PMID:
24957332
20.

Robert E. Steiner CBE, MD, FRCP, FRCR.

Bydder GM.

Radiology. 2014 Jun;271(3):930. doi: 10.1148/radiol.14144011. No abstract available.

PMID:
24848967
21.

Ultrashort echo time (UTE) magnetic resonance imaging of the short T2 components in white matter of the brain using a clinical 3T scanner.

Du J, Ma G, Li S, Carl M, Szeverenyi NM, VandenBerg S, Corey-Bloom J, Bydder GM.

Neuroimage. 2014 Feb 15;87:32-41. doi: 10.1016/j.neuroimage.2013.10.053. Epub 2013 Nov 2.

22.
23.

Ultrashort echo time bi-component analysis of cortical bone--a field dependence study.

Li S, Chang EY, Bae WC, Chung CB, Gao S, Bao S, Bydder GM, Hua Y, Du J.

Magn Reson Med. 2014 Mar;71(3):1075-81. doi: 10.1002/mrm.24769.

24.

Qualitative and quantitative ultrashort-TE MRI of cortical bone.

Du J, Bydder GM.

NMR Biomed. 2013 May;26(5):489-506. doi: 10.1002/nbm.2906. Epub 2012 Dec 28. Review.

25.

Morphology of the cartilaginous endplates in human intervertebral disks with ultrashort echo time MR imaging.

Bae WC, Statum S, Zhang Z, Yamaguchi T, Wolfson T, Gamst AC, Du J, Bydder GM, Masuda K, Chung CB.

Radiology. 2013 Feb;266(2):564-74. doi: 10.1148/radiol.12121181. Epub 2012 Nov 28.

26.

Dual inversion recovery ultrashort echo time (DIR-UTE) imaging and quantification of the zone of calcified cartilage (ZCC).

Du J, Carl M, Bae WC, Statum S, Chang EY, Bydder GM, Chung CB.

Osteoarthritis Cartilage. 2013 Jan;21(1):77-85. doi: 10.1016/j.joca.2012.09.009. Epub 2012 Sep 28.

27.

Assessment of cortical bone with clinical and ultrashort echo time sequences.

Du J, Hermida JC, Diaz E, Corbeil J, Znamirowski R, D'Lima DD, Bydder GM.

Magn Reson Med. 2013 Sep;70(3):697-704. doi: 10.1002/mrm.24497. Epub 2012 Sep 21.

28.
29.

Prospective study of functional bone marrow-sparing intensity modulated radiation therapy with concurrent chemotherapy for pelvic malignancies.

Liang Y, Bydder M, Yashar CM, Rose BS, Cornell M, Hoh CK, Lawson JD, Einck J, Saenz C, Fanta P, Mundt AJ, Bydder GM, Mell LK.

Int J Radiat Oncol Biol Phys. 2013 Feb 1;85(2):406-14. doi: 10.1016/j.ijrobp.2012.04.044. Epub 2012 Jun 9.

PMID:
22687195
30.

Ultrashort-echo time MR imaging of the patella with bicomponent analysis: correlation with histopathologic and polarized light microscopic findings.

Pauli C, Bae WC, Lee M, Lotz M, Bydder GM, D'Lima DL, Chung CB, Du J.

Radiology. 2012 Aug;264(2):484-93. doi: 10.1148/radiol.12111883. Epub 2012 May 31.

31.

Ultrashort TE T1ρ magic angle imaging.

Du J, Statum S, Znamirowski R, Bydder GM, Chung CB.

Magn Reson Med. 2013 Mar 1;69(3):682-7. doi: 10.1002/mrm.24296. Epub 2012 Apr 26.

32.

Ultrashort echo time (UTE) imaging with bi-component analysis: bound and free water evaluation of bovine cortical bone subject to sequential drying.

Biswas R, Bae W, Diaz E, Masuda K, Chung CB, Bydder GM, Du J.

Bone. 2012 Mar;50(3):749-55. doi: 10.1016/j.bone.2011.11.029. Epub 2011 Dec 10.

34.

Ultrashort echo time imaging with bicomponent analysis.

Du J, Diaz E, Carl M, Bae W, Chung CB, Bydder GM.

Magn Reson Med. 2012 Mar;67(3):645-9. doi: 10.1002/mrm.23047. Epub 2011 Oct 27.

35.

Ultrashort echo time spectroscopic imaging (UTESI): an efficient method for quantifying bound and free water.

Diaz E, Chung CB, Bae WC, Statum S, Znamirowski R, Bydder GM, Du J.

NMR Biomed. 2012 Jan;25(1):161-8. doi: 10.1002/nbm.1728. Epub 2011 Jul 15.

PMID:
21766381
36.

Short T2 contrast with three-dimensional ultrashort echo time imaging.

Du J, Bydder M, Takahashi AM, Carl M, Chung CB, Bydder GM.

Magn Reson Imaging. 2011 May;29(4):470-82. doi: 10.1016/j.mri.2010.11.003.

37.

Direct imaging and quantification of carotid plaque calcification.

Du J, Corbeil J, Znamirowski R, Angle N, Peterson M, Bydder GM, Kahn AM.

Magn Reson Med. 2011 Apr;65(4):1013-20. doi: 10.1002/mrm.22682. Epub 2010 Nov 30.

38.

Ultrashort TE MR imaging of bovine cortical bone: the effect of water loss on the T1 and T2* relaxation times.

Kokabi N, Bae W, Diaz E, Chung CB, Bydder GM, Du J.

Magn Reson Med. 2011 Aug;66(2):476-82. doi: 10.1002/mrm.22859. Epub 2011 Feb 28.

39.

Optimization of iron oxide nanoparticle detection using ultrashort echo time pulse sequences: comparison of T1, T2*, and synergistic T1- T2* contrast mechanisms.

Girard OM, Du J, Agemy L, Sugahara KN, Kotamraju VR, Ruoslahti E, Bydder GM, Mattrey RF.

Magn Reson Med. 2011 Jun;65(6):1649-60. doi: 10.1002/mrm.22755. Epub 2011 Feb 8.

40.

Qualitative and quantitative ultrashort echo time (UTE) imaging of cortical bone.

Du J, Carl M, Bydder M, Takahashi A, Chung CB, Bydder GM.

J Magn Reson. 2010 Dec;207(2):304-11. doi: 10.1016/j.jmr.2010.09.013. Epub 2010 Sep 25.

PMID:
20980179
41.

Dipolar anisotropy fiber imaging in a goat knee meniscus.

Szeverenyi NM, Bydder GM.

Magn Reson Med. 2011 Feb;65(2):463-70. doi: 10.1002/mrm.22645. Epub 2010 Oct 11.

42.

Conventional and ultrashort time-to-echo magnetic resonance imaging of articular cartilage, meniscus, and intervertebral disk.

Bae WC, Du J, Bydder GM, Chung CB.

Top Magn Reson Imaging. 2010 Oct;21(5):275-89. doi: 10.1097/RMR.0b013e31823ccebc. Review.

43.

Ultrashort TE T1rho (UTE T1rho) imaging of the Achilles tendon and meniscus.

Du J, Carl M, Diaz E, Takahashi A, Han E, Szeverenyi NM, Chung CB, Bydder GM.

Magn Reson Med. 2010 Sep;64(3):834-42. doi: 10.1002/mrm.22474.

44.

A quantitative approach to sequence and image weighting.

Yokoo T, Bae WC, Hamilton G, Karimi A, Borgstede JP, Bowen BC, Sirlin CB, Chung CB, Crues JV, Bradley WG, Bydder GM.

J Comput Assist Tomogr. 2010 May-Jun;34(3):317-31. doi: 10.1097/RCT.0b013e3181d3449a. Review.

PMID:
20498530
45.

Dual inversion recovery, ultrashort echo time (DIR UTE) imaging: creating high contrast for short-T(2) species.

Du J, Takahashi AM, Bae WC, Chung CB, Bydder GM.

Magn Reson Med. 2010 Feb;63(2):447-55. doi: 10.1002/mrm.22257.

46.

Quantifying sclerotic bone metastases with 2D ultra short TE MRI: a feasibility study.

Messiou C, Collins DJ, Morgan VA, Robson MD, deBono JS, Bydder GM, deSouza NM.

Cancer Biomark. 2010;7(4):211-8. doi: 10.3233/CBM-2010-0189.

PMID:
21576814
47.

Orientational analysis of the Achilles tendon and enthesis using an ultrashort echo time spectroscopic imaging sequence.

Du J, Chiang AJ, Chung CB, Statum S, Znamirowski R, Takahashi A, Bydder GM.

Magn Reson Imaging. 2010 Feb;28(2):178-84. doi: 10.1016/j.mri.2009.06.002. Epub 2009 Aug 19.

PMID:
19695811
48.

Ultrashort TE imaging with off-resonance saturation contrast (UTE-OSC).

Du J, Takahashi AM, Bydder M, Chung CB, Bydder GM.

Magn Reson Med. 2009 Aug;62(2):527-31. doi: 10.1002/mrm.22007.

49.

Magic angle effect in magnetic resonance imaging of the Achilles tendon and enthesis.

Du J, Pak BC, Znamirowski R, Statum S, Takahashi A, Chung CB, Bydder GM.

Magn Reson Imaging. 2009 May;27(4):557-64. doi: 10.1016/j.mri.2008.09.003. Epub 2008 Nov 20.

PMID:
19022600
50.

Magnetic resonance imaging of short T2 relaxation components in the musculoskeletal system.

Bydder GM, Chung CB.

Skeletal Radiol. 2009 Mar;38(3):201-5. doi: 10.1007/s00256-008-0592-7. Review. No abstract available.

PMID:
18941741

Supplemental Content

Loading ...
Support Center