Format
Sort by
Items per page

Send to

Choose Destination

Links from PubMed

Items: 1 to 20 of 56

1.

Radiostereometry of hip prostheses. Review of methodology and clinical results.

Kärrholm J, Herberts P, Hultmark P, Malchau H, Nivbrant B, Thanner J.

Clin Orthop Relat Res. 1997 Nov;(344):94-110.

PMID:
9372762
3.

Uncemented total hip arthroplasty for primary osteoarthritis in young patients: a mid-to long-term follow-up study from the Finnish Arthroplasty Register.

Eskelinen A, Remes V, Helenius I, Pulkkinen P, Nevalainen J, Paavolainen P.

Acta Orthop. 2006 Feb;77(1):57-70.

PMID:
16534703
4.

Total hip arthroplasty for primary osteoarthrosis in younger patients in the Finnish arthroplasty register. 4,661 primary replacements followed for 0-22 years.

Eskelinen A, Remes V, Helenius I, Pulkkinen P, Nevalainen J, Paavolainen P.

Acta Orthop. 2005 Feb;76(1):28-41.

PMID:
15788305
5.

[Early aseptic loosening of the CF 30 femoral stem].

Kovanda M, Havlícek V, Hudec J.

Acta Chir Orthop Traumatol Cech. 2007 Feb;74(1):59-64. Czech.

PMID:
17331456
6.

[Long-term experience with the combined ARBOND hydroxyapatite coating in implant osteointegration].

Landor I, Vavrík P, Jahoda D, Pokorný D, Ballay R, Sosna A.

Acta Chir Orthop Traumatol Cech. 2009 Jun;76(3):172-8. Czech.

PMID:
19595277
7.

[Personal experience with the Wagner revision stem in hip joint reoperations].

Cech O, Stehlík J, Krbec M, Vrecion V.

Acta Chir Orthop Traumatol Cech. 2001;68(3):148-61. Czech.

PMID:
11706537
8.

[Acetabular revision for aseptic loosening in total hip arthroplasty using cementless cup and impacted morselized allograft].

Parratte S, Argenson JN, Flecher X, Aubaniac JM.

Rev Chir Orthop Reparatrice Appar Mot. 2007 May;93(3):255-63. French.

PMID:
17534208
9.

The Richards Series 2 total hip prosthesis: a 13-year study and radiographic evaluation.

Laursen JO, Petersen B, Mossing NB.

Orthopedics. 1998 Mar;21(3):277-82.

PMID:
9547812
10.

[Cementless socket fixation based on the "press-fit" concept in total hip joint arthroplasty].

Morscher EW, Widmer KH, Bereiter H, Elke R, Schenk R.

Acta Chir Orthop Traumatol Cech. 2002;69(1):8-15. German.

PMID:
11951572
11.

Primary total hip arthroplasty with a flattened press-fit acetabular component in osteoarthritis and inflammatory arthritis: a prospective study on 416 hips with 6-10 years follow-up.

Zwartelé RE, Olsthoorn PG, Pöll RG, Brand R, Doets HC.

Arch Orthop Trauma Surg. 2008 Dec;128(12):1379-86. doi: 10.1007/s00402-008-0731-6. Epub 2008 Aug 30.

PMID:
18758793
12.
13.

Conus hip prosthesis.

Wagner H, Wagner M.

Acta Chir Orthop Traumatol Cech. 2001;68(4):213-21.

PMID:
11706545
14.

Long-term porous-coated cup survivorship using spikes, screws, and press-fitting for initial fixation.

Engh CA, Hopper RH Jr, Engh CA Jr.

J Arthroplasty. 2004 Oct;19(7 Suppl 2):54-60.

PMID:
15457419
15.

Migration, stem shape, and surface finish in cemented total hip arthroplasty.

Huiskes R, Verdonschot N, Nivbrant B.

Clin Orthop Relat Res. 1998 Oct;(355):103-12.

PMID:
9917595
16.

[Long-term results of the Schenker cementless femoral component].

Dzupa V, Cech O, Sesták M, Klézl Z.

Acta Chir Orthop Traumatol Cech. 2004;71(2):93-100. Czech.

PMID:
15151096
17.

The Norwegian Arthroplasty Register: 11 years and 73,000 arthroplasties.

Havelin LI, Engesaeter LB, Espehaug B, Furnes O, Lie SA, Vollset SE.

Acta Orthop Scand. 2000 Aug;71(4):337-53.

PMID:
11028881
18.

[Metal-on-metal hip replacement using Metasul cups cemented into Muller reinforcement rings after a mean 5-year (3-8) follow-up: improvement of acetabular fixation by comparing with direct cementation to bone].

Girard J, Herent S, Combes A, Pinoit Y, Soenen M, Laffargue P, Migaud H.

Rev Chir Orthop Reparatrice Appar Mot. 2008 Jun;94(4):346-53. doi: 10.1016/j.rco.2007.11.004. Epub 2008 Mar 4. French.

PMID:
18555860
19.

[Complications with the acetabular cup in the CLS total hip joint endoprosthesis].

Rozkydal Z, Janícek P, Deduch J, Hudecek F.

Acta Chir Orthop Traumatol Cech. 2001;68(2):85-92. Czech.

PMID:
11706722
20.

Early failure of smooth hydroxyapatite-coated press-fit acetabular cup--7 years of follow-up.

Cheung KW, Yung SH, Wong KC, Chiu KH.

J Arthroplasty. 2005 Aug;20(5):627-31.

PMID:
16309999

Supplemental Content

Support Center