Format
Sort by
Items per page

Send to

Choose Destination

Links from PubMed

Items: 1 to 20 of 153

1.

Fast immunosensing technique to detect Legionella pneumophila in different natural and anthropogenic environments: comparative and collaborative trials.

Bedrina B, Macián S, Solís I, Fernández-Lafuente R, Baldrich E, Rodríguez G.

BMC Microbiol. 2013 Apr 22;13:88. doi: 10.1186/1471-2180-13-88.

2.

Validation of the Legipid bioalarm Legionella assay.

Rodríguez Albalat G, Bedrina Broch B, Jiménez Bono M.

J AOAC Int. 2012 Sep-Oct;95(5):1440-51.

PMID:
23175978
3.

Method modification of the Legipid® Legionella fast detection test kit.

Albalat GR, Broch BB, Bono MJ.

J AOAC Int. 2014 Sep-Oct;97(5):1403-9. doi: 10.5740/jaoacint.14-029.

PMID:
25902991
4.

Evaluation of a Legionella urinary antigen enzyme immunoassay for rapid detection of Legionella pneumophila in water samples.

Blanco S, Prat C, Sánchez MD, Ferrer D, Pellicer T, Haba L, Latorre I, Vilaplana C, Ausina V, Domínguez J.

Int J Hyg Environ Health. 2008 Mar;211(1-2):168-71. Epub 2007 Mar 27.

PMID:
17392021
5.

Rapid and quantitative detection of Legionella pneumophila applying immunomagnetic separation and flow cytometry.

Füchslin HP, Kötzsch S, Keserue HA, Egli T.

Cytometry A. 2010 Mar;77(3):264-74. doi: 10.1002/cyto.a.20858.

6.

Rapid detection and enumeration of Legionella pneumophila in hot water systems by solid-phase cytometry.

Aurell H, Catala P, Farge P, Wallet F, Le Brun M, Helbig JH, Jarraud S, Lebaron P.

Appl Environ Microbiol. 2004 Mar;70(3):1651-7.

7.

Quantitative detection of Legionella pneumophila in water samples by immunomagnetic purification and real-time PCR amplification of the dotA gene.

Yáñez MA, Carrasco-Serrano C, Barberá VM, Catalán V.

Appl Environ Microbiol. 2005 Jul;71(7):3433-41.

8.
9.
10.

Rapid detection of total and viable Legionella pneumophila in tap water by immunomagnetic separation, double fluorescent staining and flow cytometry.

Keserue HA, Baumgartner A, Felleisen R, Egli T.

Microb Biotechnol. 2012 Nov;5(6):753-63. doi: 10.1111/j.1751-7915.2012.00366.x.

11.

Factors affecting the recovery of Legionella pneumophila serogroup 1 from cooling tower water systems.

Lu HF, Tsou MF, Huang SY, Tsai WC, Chung JG, Cheng KS.

J Microbiol Immunol Infect. 2001 Sep;34(3):161-6.

PMID:
11605805
12.

The rapid and specific real-time detection of Legionella pneumophila in water samples using Optical Waveguide Lightmode Spectroscopy.

Cooper IR, Meikle ST, Standen G, Hanlon GW, Santin M.

J Microbiol Methods. 2009 Jul;78(1):40-4. doi: 10.1016/j.mimet.2009.04.004. Epub 2009 Apr 17.

PMID:
19376163
13.

Detection limits of Legionella pneumophila in environmental samples after co-culture with Acanthamoeba polyphaga.

Conza L, Casati S, Gaia V.

BMC Microbiol. 2013 Feb 26;13:49. doi: 10.1186/1471-2180-13-49.

14.

Inter-laboratory validation of a rapid assay for the detection and quantification of Legionella spp. in water samples.

Bargellini A, Marchesi I, Leoni E, Mansi A, Cristino S, Marcelloni AM, Borella P.

Lett Appl Microbiol. 2010 Oct;51(4):421-7. doi: 10.1111/j.1472-765X.2010.02910.x. Epub 2010 Aug 26.

15.

Evaluation of an immunomagnetic separation assay in combination with cultivation to improve Legionella pneumophila serogroup 1 recovery from environmental samples.

Allegra S, Girardot F, Grattard F, Berthelot P, Helbig JH, Pozzetto B, Riffard S.

J Appl Microbiol. 2011 Apr;110(4):952-61.

16.

Rapid method for enumeration of viable Legionella pneumophila and other Legionella spp. in water.

Delgado-Viscogliosi P, Simonart T, Parent V, Marchand G, Dobbelaere M, Pierlot E, Pierzo V, Menard-Szczebara F, Gaudard-Ferveur E, Delabre K, Delattre JM.

Appl Environ Microbiol. 2005 Jul;71(7):4086-96.

17.

Development of an improved PCR-ICT hybrid assay for direct detection of Legionellae and Legionella pneumophila from cooling tower water specimens.

Horng YT, Soo PC, Shen BJ, Hung YL, Lo KY, Su HP, Wei JR, Hsieh SC, Hsueh PR, Lai HC.

Water Res. 2006 Jun;40(11):2221-9. Epub 2006 May 19.

PMID:
16713613
18.

Evaluation of the usefulness of a new direct immunofluorescence assay (ScanVIT-Legionella) for monitoring hospital water systems contaminated with Legionella spp.

Ditommaso S, Giacomuzzi M, Gentile M, Zotti CM.

Lett Appl Microbiol. 2010 Apr;50(4):341-6. doi: 10.1111/j.1472-765X.2010.02797.x. Epub 2010 Jan 15.

19.

Automated immunomagnetic processing and separation of Legionella pneumophila with manual detection by sandwich ELISA and PCR amplification of the ompS gene.

Reidt U, Geisberger B, Heller C, Friedberger A.

J Lab Autom. 2011 Apr;16(2):157-64. doi: 10.1016/j.jala.2010.07.003. Epub 2010 Oct 6.

PMID:
21609698
20.

Detection of Legionella spp. in cooling tower water by the polymerase chain reaction method.

Koide M, Saito A, Kusano N, Higa F.

Appl Environ Microbiol. 1993 Jun;59(6):1943-6.

Supplemental Content

Support Center