Format
Sort by
Items per page

Send to

Choose Destination

Links from PubMed

Items: 1 to 20 of 292

1.

Generalized INverse imaging (GIN): ultrafast fMRI with physiological noise correction.

Boyacioğlu R, Barth M.

Magn Reson Med. 2013 Oct;70(4):962-71. doi: 10.1002/mrm.24528. Epub 2012 Oct 24.

PMID:
23097342
2.

High-resolution functional MRI at 3 T: 3D/2D echo-planar imaging with optimized physiological noise correction.

Lutti A, Thomas DL, Hutton C, Weiskopf N.

Magn Reson Med. 2013 Jun;69(6):1657-64. doi: 10.1002/mrm.24398. Epub 2012 Jul 20.

3.

BOLD sensitivity and SNR characteristics of parallel imaging-accelerated single-shot multi-echo EPI for fMRI.

Bhavsar S, Zvyagintsev M, Mathiak K.

Neuroimage. 2014 Jan 1;84:65-75. doi: 10.1016/j.neuroimage.2013.08.007. Epub 2013 Aug 15.

PMID:
23954488
4.
5.

Temporal SNR characteristics in segmented 3D-EPI at 7T.

van der Zwaag W, Marques JP, Kober T, Glover G, Gruetter R, Krueger G.

Magn Reson Med. 2012 Feb;67(2):344-52. doi: 10.1002/mrm.23007. Epub 2011 Jun 7.

6.

Physiological MR signal variations within the brain at 3 T.

Klose U, Friese S, Erb M, Grodd W.

Biomed Tech (Berl). 2007 Feb;52(1):126-9.

PMID:
17313348
7.

Investigating the benefits of multi-echo EPI for fMRI at 7 T.

Poser BA, Norris DG.

Neuroimage. 2009 May 1;45(4):1162-72. doi: 10.1016/j.neuroimage.2009.01.007. Epub 2009 Jan 21.

PMID:
19349231
8.

Signal fluctuations in fMRI data acquired with 2D-EPI and 3D-EPI at 7 Tesla.

Jorge J, Figueiredo P, van der Zwaag W, Marques JP.

Magn Reson Imaging. 2013 Feb;31(2):212-20. doi: 10.1016/j.mri.2012.07.001. Epub 2012 Aug 24.

PMID:
22921734
9.

Diffusion-weighted 3D multislab echo planar imaging for high signal-to-noise ratio efficiency and isotropic image resolution.

Engström M, Skare S.

Magn Reson Med. 2013 Dec;70(6):1507-14. doi: 10.1002/mrm.24594. Epub 2013 Jan 28.

PMID:
23359357
10.

Susceptibility compensated fMRI study using a tailored RF echo planar imaging sequence.

Chung JY, Yoon HW, Kim YB, Park HW, Cho ZH.

J Magn Reson Imaging. 2009 Jan;29(1):221-8. doi: 10.1002/jmri.21397.

PMID:
19097092
11.

Improving robustness and reliability of phase-sensitive fMRI analysis using temporal off-resonance alignment of single-echo timeseries (TOAST).

Hahn AD, Nencka AS, Rowe DB.

Neuroimage. 2009 Feb 1;44(3):742-52. doi: 10.1016/j.neuroimage.2008.10.001. Epub 2008 Oct 18.

12.

Enhancement of temporal resolution and BOLD sensitivity in real-time fMRI using multi-slab echo-volumar imaging.

Posse S, Ackley E, Mutihac R, Rick J, Shane M, Murray-Krezan C, Zaitsev M, Speck O.

Neuroimage. 2012 May 15;61(1):115-30. doi: 10.1016/j.neuroimage.2012.02.059. Epub 2012 Feb 28.

13.

Differentiating BOLD and non-BOLD signals in fMRI time series using multi-echo EPI.

Kundu P, Inati SJ, Evans JW, Luh WM, Bandettini PA.

Neuroimage. 2012 Apr 15;60(3):1759-70. doi: 10.1016/j.neuroimage.2011.12.028. Epub 2011 Dec 23.

14.

Compressed sensing fMRI using gradient-recalled echo and EPI sequences.

Zong X, Lee J, John Poplawsky A, Kim SG, Ye JC.

Neuroimage. 2014 May 15;92:312-21. doi: 10.1016/j.neuroimage.2014.01.045. Epub 2014 Feb 2.

15.

Parallel EPI artifact correction (PEAC) for N/2 ghost suppression in neuroimaging applications.

Li H, Fox-Neff K, Vaughan B, French D, Szaflarski JP, Li Y.

Magn Reson Imaging. 2013 Jul;31(6):1022-8. doi: 10.1016/j.mri.2013.03.021. Epub 2013 Apr 16.

PMID:
23601363
16.

Isotropic submillimeter fMRI in the human brain at 7 T: combining reduced field-of-view imaging and partially parallel acquisitions.

Heidemann RM, Ivanov D, Trampel R, Fasano F, Meyer H, Pfeuffer J, Turner R.

Magn Reson Med. 2012 Nov;68(5):1506-16. doi: 10.1002/mrm.24156. Epub 2012 Jan 9.

PMID:
22231859
17.
18.

Rapid full-brain fMRI with an accelerated multi shot 3D EPI sequence using both UNFOLD and GRAPPA.

Afacan O, Hoge WS, Janoos F, Brooks DH, Morocz IA.

Magn Reson Med. 2012 May;67(5):1266-74. doi: 10.1002/mrm.23106. Epub 2011 Nov 16.

PMID:
22095768
19.

Improved temporal resolution for functional studies with reduced number of segments with three-dimensional echo planar imaging.

Narsude M, van der Zwaag W, Kober T, Gruetter R, Marques JP.

Magn Reson Med. 2014 Sep;72(3):786-92. doi: 10.1002/mrm.24975. Epub 2013 Oct 17.

PMID:
24136782
20.

Quantifying the spatial resolution of the gradient echo and spin echo BOLD response at 3 Tesla.

Parkes LM, Schwarzbach JV, Bouts AA, Deckers RH, Pullens P, Kerskens CM, Norris DG.

Magn Reson Med. 2005 Dec;54(6):1465-72.

Supplemental Content

Support Center