Format
Sort by
Items per page

Send to

Choose Destination

Links from PubMed

Items: 1 to 20 of 115

1.

Photoacoustic imaging of coronary artery stents.

Su JL, Wang B, Emelianov SY.

Opt Express. 2009 Oct 26;17(22):19894-901. doi: 10.1364/OE.17.019894.

PMID:
19997212
2.

Impact of device geometry on the imaging characteristics of an intravascular photoacoustic catheter.

Wu M, Jansen K, Springeling G, van der Steen AF, van Soest G.

Appl Opt. 2014 Dec 1;53(34):8131-9. doi: 10.1364/AO.53.008131.

PMID:
25607973
3.

Photoacoustic imaging of the bladder: a pilot study.

Kamaya A, Vaithilingam S, Chung BI, Oralkan O, Khuri-Yakub BT.

J Ultrasound Med. 2013 Jul;32(7):1245-50. doi: 10.7863/ultra.32.7.1245.

PMID:
23804347
4.

Update on multidetector coronary CT angiography of coronary stents: in vitro evaluation of 29 different stent types with dual-source CT.

Maintz D, Burg MC, Seifarth H, Bunck AC, Ozgün M, Fischbach R, Jürgens KU, Heindel W.

Eur Radiol. 2009 Jan;19(1):42-9. doi: 10.1007/s00330-008-1132-5. Epub 2008 Aug 6.

PMID:
18682956
5.

In vitro imaging of coronary artery stents: are there differences between 16- and 64-slice CT scanners?

Wolf F, Feuchtner GM, Homolka P, Langenberger H, Stadler A, Bader TR, Weber M, Lammer J, Loewe C.

Eur J Radiol. 2008 Dec;68(3):465-70. Epub 2007 Oct 29.

PMID:
17913428
6.

Real-time photoacoustic and ultrasound dual-modality imaging system facilitated with graphics processing unit and code parallel optimization.

Yuan J, Xu G, Yu Y, Zhou Y, Carson PL, Wang X, Liu X.

J Biomed Opt. 2013 Aug;18(8):86001. doi: 10.1117/1.JBO.18.8.086001.

7.

Cardiovascular stent design and vessel stresses: a finite element analysis.

Lally C, Dolan F, Prendergast PJ.

J Biomech. 2005 Aug;38(8):1574-81. Erratum in: J Biomech. 2006;39(9):1760.

PMID:
15958213
8.

Coronary artery stent imaging with 128-slice dual-source CT using high-pitch spiral acquisition in a cardiac phantom: comparison with the sequential and low-pitch spiral mode.

Wolf F, Leschka S, Loewe C, Homolka P, Plank C, Schernthaner R, Bercaczy D, Goetti R, Lammer J, Friedrich G, Marincek B, Alkadhi H, Feuchtner G.

Eur Radiol. 2010 Sep;20(9):2084-91. doi: 10.1007/s00330-010-1792-9. Epub 2010 Apr 16.

PMID:
20397019
9.

Real-time photoacoustic tomograpghy using linear array probe and detection of line structure using Hough transform.

Shin SW, Park J, Shin DH, Song CG, Kim KS.

Biomed Mater Eng. 2015;26 Suppl 1:S1483-90. doi: 10.3233/BME-151447.

PMID:
26405912
10.

3D reconstruction of coronary stents in vivo based on motion compensated X-ray angiograms.

Movassaghi B, Schaefer D, Grass M, Rasche V, Wink O, Garcia JA, Chen JY, Messenger JC, Carroll JD.

Med Image Comput Comput Assist Interv. 2006;9(Pt 2):177-84.

PMID:
17354770
11.

Thermoacoustic and photoacoustic sensing of temperature.

Pramanik M, Wang LV.

J Biomed Opt. 2009 Sep-Oct;14(5):054024. doi: 10.1117/1.3247155.

12.

High-resolution ex vivo imaging of coronary artery stents using 64-slice computed tomography--initial experience.

Rist C, Nikolaou K, Flohr T, Wintersperger BJ, Reiser MF, Becker CR.

Eur Radiol. 2006 Jul;16(7):1564-9. Epub 2006 Mar 2.

PMID:
16518653
13.

Assessing and improving acoustic radiation force image quality using a 1.5-D transducer design.

Dhanaliwala AH, Hossack JA, Mauldin FW.

IEEE Trans Ultrason Ferroelectr Freq Control. 2012 Jul;59(7):1602-8. doi: 10.1109/TUFFC.2012.2360.

14.

Thin polymer etalon arrays for high-resolution photoacoustic imaging.

Hou Y, Huang SW, Ashkenazi S, Witte R, O'Donnell M.

J Biomed Opt. 2008 Nov-Dec;13(6):064033. doi: 10.1117/1.3042260.

15.

A Broadband Polyvinylidene Difluoride-Based Hydrophone with Integrated Readout Circuit for Intravascular Photoacoustic Imaging.

Daeichin V, Chen C, Ding Q, Wu M, Beurskens R, Springeling G, Noothout E, Verweij MD, van Dongen KW, Bosch JG, van der Steen AF, de Jong N, Pertijs M, van Soest G.

Ultrasound Med Biol. 2016 May;42(5):1239-43. doi: 10.1016/j.ultrasmedbio.2015.12.016. Epub 2016 Feb 5.

PMID:
26856788
16.

Stainless and shape memory alloy coronary stents: a computational study on the interaction with the vascular wall.

Migliavacca F, Petrini L, Massarotti P, Schievano S, Auricchio F, Dubini G.

Biomech Model Mechanobiol. 2004 Jun;2(4):205-17. Epub 2004 Mar 17.

PMID:
15029511
17.

Stent shape estimation through a comprehensive interpretation of intravascular ultrasound images.

Ciompi F, Balocco S, Caus C, Mauri J, Radeva P.

Med Image Comput Comput Assist Interv. 2013;16(Pt 2):345-52.

PMID:
24579159
18.

Detection of stent fractures: a comparison of 64-slice CT, conventional cine-angiography, and intravascular ultrasonography.

Pang JH, Kim D, Beohar N, Meyers SN, Lloyd-Jones D, Yaghmai V.

Acad Radiol. 2009 Apr;16(4):412-7. doi: 10.1016/j.acra.2008.10.010.

PMID:
19268852
19.

In vivo high-resolution 3D photoacoustic imaging of superficial vascular anatomy.

Zhang EZ, Laufer JG, Pedley RB, Beard PC.

Phys Med Biol. 2009 Feb 21;54(4):1035-46. doi: 10.1088/0031-9155/54/4/014. Epub 2009 Jan 23.

PMID:
19168938
20.

Optimized shear wave generation using hybrid beamforming methods.

Nabavizadeh A, Greenleaf JF, Fatemi M, Urban MW.

Ultrasound Med Biol. 2014 Jan;40(1):188-99. doi: 10.1016/j.ultrasmedbio.2013.08.016. Epub 2013 Oct 18.

Supplemental Content

Support Center