Format
Sort by
Items per page

Send to

Choose Destination

Search results

Items: 1 to 20 of 173

1.

Safety and accuracy of robot-assisted versus fluoroscopy-assisted pedicle screw insertion in thoracolumbar spinal surgery: a prospective randomized controlled trial.

Han X, Tian W, Liu Y, Liu B, He D, Sun Y, Han X, Fan M, Zhao J, Xu Y, Zhang Q.

J Neurosurg Spine. 2019 Feb 8:1-8. doi: 10.3171/2018.10.SPINE18487. [Epub ahead of print]

PMID:
30738398
2.

Pedicle Screw Placement Using Augmented Reality Surgical Navigation with Intraoperative 3D Imaging: A First In-Human Prospective Cohort Study.

Terander AE, Burström G, Nachabe R, Skulason H, Pedersen K, Fagerlund M, Ståhl F, Charalampidis A, Söderman M, Holmin S, Babic D, Jenniskens I, Edström E, Gerdhem P.

Spine (Phila Pa 1976). 2018 Sep 17. doi: 10.1097/BRS.0000000000002876. [Epub ahead of print]

PMID:
30234816
3.

Use of the Airo mobile intraoperative CT system versus the O-arm for transpedicular screw fixation in the thoracic and lumbar spine: a retrospective cohort study of 263 patients.

Scarone P, Vincenzo G, Distefano D, Del Grande F, Cianfoni A, Presilla S, Reinert M.

J Neurosurg Spine. 2018 Oct;29(4):397-406. doi: 10.3171/2018.1.SPINE17927. Epub 2018 Jul 6.

PMID:
29979141
4.

Photoacoustic imaging of a human vertebra: implications for guiding spinal fusion surgeries.

Shubert J, Lediju Bell MA.

Phys Med Biol. 2018 Jul 11;63(14):144001. doi: 10.1088/1361-6560/aacdd3.

PMID:
29923832
5.

Repeat Surgical Interventions Following "Definitive" Instrumentation and Fusion for Idiopathic Scoliosis: 25-Year Update.

Mignemi M, Tran D, Ramo B, Richards BS.

Spine Deform. 2018 Jul - Aug;6(4):409-416. doi: 10.1016/j.jspd.2017.12.006.

PMID:
29886912
6.

Transmuscular Ultrasonography of the Placement of Thoracolumbar Pedicle Screws: A Cadaveric Study.

Xie CL, Huang QS, Wu L, Xu L, Dou HC, Wang XY, Lin ZK.

World Neurosurg. 2018 Jul;115:e360-e365. doi: 10.1016/j.wneu.2018.04.057. Epub 2018 Apr 17.

PMID:
29678714
7.

Simultaneous Endovascular Repair of a Thoracic Aortic Injury during Posterior Pedicle Screw Removal: A Case Report.

Martin S, Lindsay R, Baker RC.

Ann Vasc Surg. 2018 Apr;48:252.e1-252.e4. doi: 10.1016/j.avsg.2017.10.021. Epub 2017 Dec 8.

PMID:
29225127
8.

End Vertebra Versus Apical Vertebra: Where are We More Likely to Misplace in Spine Deformity?

Sarwahi V, Wendolowski SF, Lo Y, Thornhill B, Amaral T.

J Pediatr Orthop. 2017 Nov 16. doi: 10.1097/BPO.0000000000001102. [Epub ahead of print]

PMID:
29189527
9.

Pedicle Screw Insertion Accuracy Using O-Arm, Robotic Guidance, or Freehand Technique: A Comparative Study.

Laudato PA, Pierzchala K, Schizas C.

Spine (Phila Pa 1976). 2018 Mar 15;43(6):E373-E378. doi: 10.1097/BRS.0000000000002449.

PMID:
29019807
10.

Revision Rate of Misplaced Pedicle Screws of the Thoracolumbar Spine-Comparison of Three-Dimensional Fluoroscopy Navigation with Freehand Placement: A Systematic Analysis and Review of the Literature.

Fichtner J, Hofmann N, Rienmüller A, Buchmann N, Gempt J, Kirschke JS, Ringel F, Meyer B, Ryang YM.

World Neurosurg. 2018 Jan;109:e24-e32. doi: 10.1016/j.wneu.2017.09.091. Epub 2017 Sep 22.

PMID:
28951183
11.

Accuracy of 837 pedicle screw positions in degenerative lumbar spine with conventional open surgery evaluated by computed tomography.

Saarenpää I, Laine T, Hirvonen J, Hurme S, Kotilainen E, Rinne J, Korhonen K, Frantzén J.

Acta Neurochir (Wien). 2017 Oct;159(10):2011-2017. doi: 10.1007/s00701-017-3289-7. Epub 2017 Aug 10.

PMID:
28799104
12.

A computed tomographic anatomical study of the upper sacrum. Application for a user guide of pelvic fixation with iliosacral screws in adult spinal deformity.

Dubory A, Bouloussa H, Riouallon G, Wolff S.

Int Orthop. 2017 Dec;41(12):2543-2553. doi: 10.1007/s00264-017-3580-5. Epub 2017 Aug 8.

PMID:
28791464
13.
14.

Radiation dose reduction in thoracic and lumbar spine instrumentation using navigation based on an intraoperative cone beam CT imaging system: a prospective randomized clinical trial.

Pireau N, Cordemans V, Banse X, Irda N, Lichtherte S, Kaminski L.

Eur Spine J. 2017 Nov;26(11):2818-2827. doi: 10.1007/s00586-017-5229-x. Epub 2017 Jul 22.

PMID:
28735464
15.

Pedicle screw placement accuracy impact and comparison between grading systems.

Theologou M, Theologou T, Zevgaridis D, Skoulios N, Matejic S, Tsonidis C.

Surg Neurol Int. 2017 Jun 27;8:131. doi: 10.4103/sni.sni_85_17. eCollection 2017.

16.

A case report of an unusual cause of postoperative leg pain after posterior lumbar fusion.

Daureeawoo R, Baliga S, Mohahmed W, Ahmed EB.

Ann Med Surg (Lond). 2017 May 22;19:29-32. doi: 10.1016/j.amsu.2017.05.007. eCollection 2017 Jul.

17.

Accuracy of a new intraoperative cone beam CT imaging technique (Artis zeego II) compared to postoperative CT scan for assessment of pedicle screws placement and breaches detection.

Cordemans V, Kaminski L, Banse X, Francq BG, Cartiaux O.

Eur Spine J. 2017 Nov;26(11):2906-2916. doi: 10.1007/s00586-017-5139-y. Epub 2017 May 20.

PMID:
28528479
18.

Evaluation of robot-guided minimally invasive implantation of 2067 pedicle screws.

Keric N, Doenitz C, Haj A, Rachwal-Czyzewicz I, Renovanz M, Wesp DMA, Boor S, Conrad J, Brawanski A, Giese A, Kantelhardt SR.

Neurosurg Focus. 2017 May;42(5):E11. doi: 10.3171/2017.2.FOCUS16552.

PMID:
28463624
19.

Accuracy of robot-guided versus freehand fluoroscopy-assisted pedicle screw insertion in thoracolumbar spinal surgery.

Molliqaj G, Schatlo B, Alaid A, Solomiichuk V, Rohde V, Schaller K, Tessitore E.

Neurosurg Focus. 2017 May;42(5):E14. doi: 10.3171/2017.3.FOCUS179.

PMID:
28463623
20.

Misplaced Cervical Screws Requiring Reoperation.

Peterson JC, Arnold PM, Smith ZA, Hsu WK, Fehlings MG, Hart RA, Hilibrand AS, Nassr A, Rahman RK, Tannoury CA, Tannoury T, Mroz TE, Currier BL, De Giacomo AF, Fogelson JL, Jobse BC, Massicotte EM, Riew KD.

Global Spine J. 2017 Apr;7(1 Suppl):46S-52S. doi: 10.1177/2192568216687527. Epub 2017 Apr 1.

Supplemental Content

Loading ...
Support Center