Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
2003 1
2015 2
2016 3
2024 0

Text availability

Article attribute

Article type

Publication date

Search Results

4 results

Results by year

Citations

1 article found by citation matching

Search results

Filters applied: . Clear all
Page 1
Influence of Ligament Properties on Tibiofemoral Mechanics in Walking.
Smith CR, Lenhart RL, Kaiser J, Vignos MF, Thelen DG. Smith CR, et al. J Knee Surg. 2016 Feb;29(2):99-106. doi: 10.1055/s-0035-1558858. Epub 2015 Sep 26. J Knee Surg. 2016. PMID: 26408997 Free PMC article.
The objective of this study was to use a multibody knee model to investigate the influence of ligament properties on tibiofemoral kinematics and cartilage contact pressures in the stance phase of walking. ...The knee was incorporated into a lowe …
The objective of this study was to use a multibody knee model to investigate the influence of ligament properties on …
The Influence of Component Alignment and Ligament Properties on Tibiofemoral Contact Forces in Total Knee Replacement.
Smith CR, Vignos MF, Lenhart RL, Kaiser J, Thelen DG. Smith CR, et al. J Biomech Eng. 2016 Feb;138(2):021017. doi: 10.1115/1.4032464. J Biomech Eng. 2016. PMID: 26769446 Free PMC article.
The study objective was to investigate the influence of coronal plane alignment and ligament properties on total knee replacement (TKR) contact loads during walking. ...Ligament properties had substantial influence on the TKR load …
The study objective was to investigate the influence of coronal plane alignment and ligament properties on total knee r …
Influence of anthropometric and mechanical variations on functional instability in the ACL-deficient knee.
Liu W, Maitland ME. Liu W, et al. Ann Biomed Eng. 2003 Nov;31(10):1153-61. doi: 10.1114/1.1615572. Ann Biomed Eng. 2003. PMID: 14649489
Individual variations in joint anatomy, tissue mechanical properties, and muscle strength of the knee are believed to affect the clinical outcome of ACL-deficient patients, but the effects have not been studied systematically. ...The model included the tibiofemor
Individual variations in joint anatomy, tissue mechanical properties, and muscle strength of the knee are believed to affect t …
The influence and biomechanical role of cartilage split line pattern on tibiofemoral cartilage stress distribution during the stance phase of gait.
Shim VB, Besier TF, Lloyd DG, Mithraratne K, Fernandez JF. Shim VB, et al. Biomech Model Mechanobiol. 2016 Feb;15(1):195-204. doi: 10.1007/s10237-015-0668-y. Epub 2015 Apr 10. Biomech Model Mechanobiol. 2016. PMID: 25861029
Three 'split line' patterns (medial-lateral, anterior-posterior and random) were implemented in a finite element model with constitutive properties referring to this 'split line' orientation as a finite element fibre field. ...