Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My NCBI Filters

Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
1975 1
1979 1
1982 3
1983 1
1984 1
1985 1
1989 5
1990 1
1992 3
1993 1
1994 1
1996 1
1997 4
1998 6
1999 5
2000 6
2001 2
2002 4
2003 4
2004 6
2005 6
2006 4
2007 3
2008 4
2009 4
2010 6
2011 8
2012 2
2013 4
2014 5
2015 3
2016 4
2017 1
2018 4
2019 10
2020 12
2021 5
2022 5
2023 6
2024 0

Text availability

Article attribute

Article type

Publication date

Search Results

136 results

Results by year

Filters applied: . Clear all
Page 1
The pathology of breast biopsy site marking devices.
Guarda LA, Tran TA. Guarda LA, et al. Am J Surg Pathol. 2005 Jun;29(6):814-9. doi: 10.1097/01.pas.0000161324.59219.ca. Am J Surg Pathol. 2005. PMID: 15897749
This report presents our experience with 54 cases of patients who had excision of breast lesions after deployment of radiographic biopsy site markers at the time of stereotactic biopsy. ...The degradation of the collagen plug appears to be associated with inf …
This report presents our experience with 54 cases of patients who had excision of breast lesions after deployment of radiographic …
A plea for the biopsy marker: how, why and why not clipping after breast biopsy?
Thomassin-Naggara I, Lalonde L, David J, Darai E, Uzan S, Trop I. Thomassin-Naggara I, et al. Breast Cancer Res Treat. 2012 Apr;132(3):881-93. doi: 10.1007/s10549-011-1847-x. Epub 2011 Nov 1. Breast Cancer Res Treat. 2012. PMID: 22042370 Review.
In the last decade, percutaneous breast biopsies have become a standard for the management of breast diseases. Biopsy clips allow for precise lesion localization, thus minimizing the volume of breast to be resected at the time of surgery. ...
In the last decade, percutaneous breast biopsies have become a standard for the management of breast diseases. Biops
Interventional breast procedures.
de Paredes ES, Langer TG, Cousins J. de Paredes ES, et al. Curr Probl Diagn Radiol. 1998 Sep-Oct;27(5):133-84. doi: 10.1016/s0363-0188(98)90010-x. Curr Probl Diagn Radiol. 1998. PMID: 9794095 Review.
The capability to provide histologic diagnoses of nonpalpable lesions by performance of percutaneous needle biopsy has revolutionized breast imaging in the past decade. The radiologist who performs percutaneous breast biopsies assumes an increased leve …
The capability to provide histologic diagnoses of nonpalpable lesions by performance of percutaneous needle biopsy has revolutionized …
Image-guided breast biopsy and localisation: recommendations for information to women and referring physicians by the European Society of Breast Imaging.
Bick U, Trimboli RM, Athanasiou A, Balleyguier C, Baltzer PAT, Bernathova M, Borbély K, Brkljacic B, Carbonaro LA, Clauser P, Cassano E, Colin C, Esen G, Evans A, Fallenberg EM, Fuchsjaeger MH, Gilbert FJ, Helbich TH, Heywang-Köbrunner SH, Herranz M, Kinkel K, Kilburn-Toppin F, Kuhl CK, Lesaru M, Lobbes MBI, Mann RM, Martincich L, Panizza P, Pediconi F, Pijnappel RM, Pinker K, Schiaffino S, Sella T, Thomassin-Naggara I, Tardivon A, Ongeval CV, Wallis MG, Zackrisson S, Forrai G, Herrero JC, Sardanelli F; European Society of Breast Imaging (EUSOBI), with language review by Europa Donna–The European Breast Cancer Coalition. Bick U, et al. Insights Imaging. 2020 Feb 5;11(1):12. doi: 10.1186/s13244-019-0803-x. Insights Imaging. 2020. PMID: 32025985 Free PMC article.
We summarise here the information to be provided to women and referring physicians about percutaneous breast biopsy and lesion localisation under imaging guidance. After explaining why a preoperative diagnosis with a percutaneous biopsy is preferred to surgic …
We summarise here the information to be provided to women and referring physicians about percutaneous breast biopsy and lesion …
Concomitant Use of Biopsy Clips and Wire Localization in Invasive Breast Cancer is Associated With Successful Clip Retrieval.
Chen JH, Canner JK, Myers K, Camp M. Chen JH, et al. Clin Breast Cancer. 2023 Apr;23(3):e163-e172. doi: 10.1016/j.clbc.2022.12.007. Epub 2022 Dec 16. Clin Breast Cancer. 2023. PMID: 36646538
Successful retrieval of the biopsy clip marking the lymph node of interest is crucial for assessment of pathologic response and locoregional disease control. METHODS: We performed a retrospective review of patients 18 years old with invasive breast cancer and …
Successful retrieval of the biopsy clip marking the lymph node of interest is crucial for assessment of pathologic response an …
Tissue marking clip for stereotactic breast biopsy: initial placement accuracy, long-term stability, and usefulness as a guide for wire localization.
Burbank F, Forcier N. Burbank F, et al. Radiology. 1997 Nov;205(2):407-15. doi: 10.1148/radiology.205.2.9356621. Radiology. 1997. PMID: 9356621
PURPOSE: To determine initial placement accuracy, long-term stability, and usefulness as a guide for wire localization for metallic marker clips placed percutaneously after stereotactic breast biopsy. MATERIALS AND METHODS: One hundred forty-nine marker clips were p …
PURPOSE: To determine initial placement accuracy, long-term stability, and usefulness as a guide for wire localization for metallic marker c …
Multi-detector row CT-guided marking technique for breast-conserving therapy of early breast cancer: margin positivity and local control rates.
Urano M, Shiraki N, Hara M, Toyama T, Shibamoto Y. Urano M, et al. Breast Cancer. 2016 Mar;23(2):252-60. doi: 10.1007/s12282-014-0562-y. Epub 2014 Sep 3. Breast Cancer. 2016. PMID: 25182526
BACKGROUND: In breast-conserving surgery (BCS), image-guided marking of the tumor border is important for preventing local recurrence and achieving a good cosmetic outcome. ...The median follow-up period was 54 and 51 months for patients with CT marking and t …
BACKGROUND: In breast-conserving surgery (BCS), image-guided marking of the tumor border is important for preventing local rec …
Surgical benefits conveyed by biopsy site marking system using ultrasound localization.
Nurko J, Mancino AT, Whitacre E, Edwards MJ. Nurko J, et al. Am J Surg. 2005 Oct;190(4):618-22. doi: 10.1016/j.amjsurg.2005.06.027. Am J Surg. 2005. PMID: 16164935
BACKGROUND: With vacuum-assisted biopsy technology all, or most, of a breast lesion may be removed during the initial biopsy; in such cases a metallic marker is often inserted at the site of the biopsy for future localization. The aim of this study was …
BACKGROUND: With vacuum-assisted biopsy technology all, or most, of a breast lesion may be removed during the initial biops
Lost clips after targeted lymph node biopsy in breast cancer patients: Follow-up of the CLIP-study.
Hartmann S, Stachs A, Gerber B, Knauerhase H, Kamin F, Kundt G, Reimer T. Hartmann S, et al. Eur J Surg Oncol. 2021 Aug;47(8):1907-1912. doi: 10.1016/j.ejso.2021.04.034. Epub 2021 Apr 30. Eur J Surg Oncol. 2021. PMID: 33962833
INTRODUCTION: Clipping and selective removal of axillary lymph nodes in breast cancer patients presenting with initially node-positive disease and achieving a nodal downstaging after primary systemic therapy is a less invasive method for axillary staging. ...CONCLUSION: Lo …
INTRODUCTION: Clipping and selective removal of axillary lymph nodes in breast cancer patients presenting with initially node-positiv …
MR-guided breast biopsy and hook wire marking using a low-field (0.23 T) scanner with optical instrument tracking.
Sequeiros RB, Reinikainen H, Sequeiros AM, Vaara T, Ojala R, Pääkkö E, Tervonen O. Sequeiros RB, et al. Eur Radiol. 2007 Mar;17(3):813-9. doi: 10.1007/s00330-006-0377-0. Epub 2006 Sep 22. Eur Radiol. 2007. PMID: 17021710
The purpose of this study was to evaluate the technical feasibility of MR-guided percutaneous breast biopsy (LCNB) and breast hook wire marking in a low-field (0.23 T) MRI system with optical instrument tracking. ...There were difficulties due to unsat …
The purpose of this study was to evaluate the technical feasibility of MR-guided percutaneous breast biopsy (LCNB) and brea
136 results