Format

Send to

Choose Destination
Int J Cardiovasc Imaging. 2019 Jul 18. doi: 10.1007/s10554-019-01668-9. [Epub ahead of print]

Could two-dimensional radial strain be considered as a novel tool to identify pre-clinical hypertrophic cardiomyopathy mutation carriers?

Author information

1
Cardiology, Cardiocentes A. De Gasperis Department, ASST GOM Niguarda Ca' Granda, Piazza ospedale maggiore 3, 20151, Milan, Italy. gloriamaria.santambrogio@ospedaleniguarda.it.
2
Cardiology, Cardiocentes A. De Gasperis Department, ASST GOM Niguarda Ca' Granda, Piazza ospedale maggiore 3, 20151, Milan, Italy.
3
School of Medicine and Surgery, Milano-Bicocca University, Milan, Italy.
4
Laboratory Medicine, ASST GOM Niguarda Ca' Granda, Milan, Italy.

Abstract

Treatment of overt form of hypertrophic cardiomyopathy (HCM) is often unsuccessful. Efforts are focused on a possible early identification in order to prevent or delaying the development of hypertrophy. Our aim was to find an echocardiographic marker able to distinguish mutation carriers without left ventricular hypertrophy (LVH) from healthy subjects. We evaluated 28 patients, members of eight families. Three types of mutation were recognized: MYBPC3 (five families), MYH7 (two families) and TNNT2 (one family). According to genetic (G) and phenotypic (Ph) features, patients were divided in three groups: Group A (10 patients), mutation carriers with LVH (G+/Ph+); Group B (9 patients), mutation carriers without LVH (G+/Ph-); Group C (9 patients), healthy subjects (G-/Ph-). Echocardiography examination was performed acquiring standard 2D, DTI and 2D-strain imaging. Global longitudinal strain (GLS) and global radial strain (GRS) at basal and mid-level were measured. GRS was significantly different between group B and C at basal level (32.18% ± 9.6 vs. 44.59% ± 12.67 respectively; p-value < 0.0001). In basal posterior and basal inferior segments this difference was particularly evident. ROC curves showed for both the involved segments good AUCs (0.931 and 0.861 for basal posterior and inferior GRS respectively) with the best predictive cut-off for basal posterior GRS at 43.65%, while it was 38.4% for basal inferior GRS. Conversely, GLS values were similar in the three group. 2D longitudinal strain is a valid technique to study HCM. Radial strain and particularly basal posterior and inferior segmental reduction could be able to identify mutation carriers in a pre-clinical phase of disease.

KEYWORDS:

Echocardiography; Hypertrophic cardiomyopathy; Sarcomeric mutations; Strain

PMID:
31321652
DOI:
10.1007/s10554-019-01668-9

Supplemental Content

Full text links

Icon for Springer
Loading ...
Support Center