Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My NCBI Filters

Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
1966 1
1968 1
1976 1
1996 1
1998 1
1999 1
2000 2
2003 2
2004 1
2006 1
2007 1
2009 1
2010 1
2011 1
2012 1
2013 4
2014 6
2015 5
2016 4
2017 7
2018 5
2019 4
2020 9
2021 7
2022 4
2023 2
2024 3

Text availability

Article attribute

Article type

Publication date

Search Results

59 results

Results by year

Filters applied: . Clear all
Page 1
Respiratory monitoring: arterial blood gas analysis, pulse oximetry, and end-tidal carbon dioxide analysis.
Proulx J. Proulx J. Clin Tech Small Anim Pract. 1999 Nov;14(4):227-30. doi: 10.1016/S1096-2867(99)80015-2. Clin Tech Small Anim Pract. 1999. PMID: 10652840 Review.
The use of arterial blood gas analysis, pulse oximetry, and capnography has become commonplace in the assessment of veterinary patients. ...Pulse oximetry and capnography are not replacements for arterial blood gas analysis, but rather serve as adjunct …
The use of arterial blood gas analysis, pulse oximetry, and capnography has become commonplace in the assessment of veterinary …
Appraisal of the 'penumbra effect' using lingual pulse oximetry in anaesthetized dogs and cats.
Mair A, Ferreira J, Ricco C, Nitzan M. Mair A, et al. Vet Anaesth Analg. 2020 Mar;47(2):177-182. doi: 10.1016/j.vaa.2019.08.050. Epub 2019 Nov 5. Vet Anaesth Analg. 2020. PMID: 31982340
OBJECTIVE: Factors described as contributors to the 'penumbra effect' in relation to pulse oximetry include optical shunting, circulatory anastomoses and probe parallelity. ...STUDY DESIGN: Prospective clinical trial. ANIMALS: A total of 30 dogs and 15 cats ( …
OBJECTIVE: Factors described as contributors to the 'penumbra effect' in relation to pulse oximetry include optical shunting, …
Two different smartwatches exhibit high accuracy in evaluating heart rate and peripheral oxygen saturation in cats when compared with the electrocardiography and transmittance pulse oximetry.
Yanmaz LE, Okur S, Ersoz U, Senocak MG, Turgut F. Yanmaz LE, et al. J Am Vet Med Assoc. 2022 Nov 2;261(2):205-209. doi: 10.2460/javma.22.08.0357. J Am Vet Med Assoc. 2022. PMID: 36322488
OBJECTIVE: To evaluate the accuracy for 2 smartwatches with oximetry technology and optical wrist heart rate (HR) or single-lead Electrocardiography (ECG) technology (Fenix 5X Plus [GF5xp], Garmin Ltd and Apple Watch 6 [AppW6], Apple Inc, respectively) versus …
OBJECTIVE: To evaluate the accuracy for 2 smartwatches with oximetry technology and optical wrist heart rate (HR) or si …
Obesity-hypoventilation syndrome and associated factors.
Espínola Rodríguez A, Lores Obradors L, Parellada Esquius N, Rubio Muñoz F, Espinosa Gonzalez N, Arellano Marcuello E. Espínola Rodríguez A, et al. Med Clin (Barc). 2018 Feb 23;150(4):125-130. doi: 10.1016/j.medcli.2017.06.019. Epub 2017 Jul 23. Med Clin (Barc). 2018. PMID: 28743403 English, Spanish.
To determine the prevalence of OHS in the population of patients with morbid obesity and to know the comorbidity related with OHS, the associated respiratory symptoms and the pulse oximetry alterations. PATIENTS AND METHOD: Descriptive study. ...Noteworthy was the h …
To determine the prevalence of OHS in the population of patients with morbid obesity and to know the comorbidity related with OHS, the assoc …
Pilot Medical Certification.
Matthews MJ, Stretanski MF. Matthews MJ, et al. 2023 Feb 6. In: StatPearls [Internet]. Treasure Island (FL): StatPearls Publishing; 2024 Jan–. 2023 Feb 6. In: StatPearls [Internet]. Treasure Island (FL): StatPearls Publishing; 2024 Jan–. PMID: 33620822 Free Books & Documents.
The courses are free to the AME, covered by taxpayers, and the CME counts towards a regular medical license (Cat 1A), but travel and other expenses are the responsibility of the AME just like any other conference. ...There is a section for "other tests" that may be perform …
The courses are free to the AME, covered by taxpayers, and the CME counts towards a regular medical license (Cat 1A), but travel and …
Correlation of CAT Score With Peak Expiratory Flow in Acute Exacerbation of COPD Patients.
Kavalci C, Yilmaz MS, Kayipmaz AE, Isık B, Celikel E, Kavalci G, Yilmaz F, Ozlem M, Sonmez BM, Celebi S. Kavalci C, et al. J Natl Med Assoc. 2016 Autumn;108(3):164-168. doi: 10.1016/j.jnma.2016.06.002. Epub 2016 Jul 30. J Natl Med Assoc. 2016. PMID: 27692357
METHODS: This observational study was conducted prospectively. CAT score was calculated and PEF measured at the time of emergency department admission. ...RESULTS: Of 123 patients included in the study, 85 (69.1%) were male and 38 (30.9%) were female. Pulse pressure …
METHODS: This observational study was conducted prospectively. CAT score was calculated and PEF measured at the time of emergency dep …
[Pulmonary function testing in the cat - an overview].
Gareis H, Schulz B. Gareis H, et al. Tierarztl Prax Ausg K Kleintiere Heimtiere. 2021 Nov;49(6):441-454. doi: 10.1055/a-1640-4123. Epub 2021 Dec 3. Tierarztl Prax Ausg K Kleintiere Heimtiere. 2021. PMID: 34861722 Review. German.
This article provides an overview of currently available pulmonary function tests in cats, divided into invasive and non-invasive methods. Invasive techniques comprise arterial blood gas analysis and measurement of pulmonary mechanics. Non-invasive techniques include pu
This article provides an overview of currently available pulmonary function tests in cats, divided into invasive and non-invasive met …
Unilateral pulmonary edema associated factors after minimally invasive mitral valve surgery.
López-Baamonde M, Eulufi S, Ascaso M, Arguis MJ, Navarro-Ripoll R, Rovira I. López-Baamonde M, et al. Rev Esp Anestesiol Reanim (Engl Ed). 2022 Mar;69(3):134-142. doi: 10.1016/j.redare.2021.03.012. Epub 2022 Mar 16. Rev Esp Anestesiol Reanim (Engl Ed). 2022. PMID: 35305949
A significant association was found between the following collected variables and the development of postoperative UPE: preoperative baseline pulse oximetry, preoperative use of ACE inhibitors, postoperative atrial fibrillation and 24 first-hours cumulative chest tu …
A significant association was found between the following collected variables and the development of postoperative UPE: preoperative baselin …
Comparison of two sedation protocols for short electroretinography in cats.
Del Sole MJ, Nejamkin P, Cavilla V, Schaiquevich P, Moreno L. Del Sole MJ, et al. J Feline Med Surg. 2018 Feb;20(2):172-178. doi: 10.1177/1098612X17703011. Epub 2017 Apr 5. J Feline Med Surg. 2018. PMID: 28379112
Other variables recorded were: systolic blood pressure, cardiac rhythm, heart rate, pulse oximetry and respiratory rate. Recorded ERG variables included a- and b-wave amplitudes and implicit times under photopic, scotopic and scotopic mixed ERG …
Other variables recorded were: systolic blood pressure, cardiac rhythm, heart rate, pulse oximetry and respirato …
59 results