Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My NCBI Filters

Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
1994 1
1995 1
1996 2
1997 2
1998 3
1999 3
2000 1
2001 4
2002 9
2003 4
2004 2
2005 5
2006 8
2007 6
2008 18
2009 19
2010 19
2011 18
2012 14
2013 37
2014 17
2015 15
2016 14
2017 16
2018 10
2019 10
2020 11
2021 8
2022 5
2023 3
2024 0

Text availability

Article attribute

Article type

Publication date

Search Results

248 results

Results by year

Filters applied: . Clear all
Page 1
Lead-Free HIFU Transducers.
Zawada T, Bove T, Astafiev K, Ringgaard E, Lou-Moeller R. Zawada T, et al. Ultrasound Med Biol. 2022 Dec;48(12):2530-2543. doi: 10.1016/j.ultrasmedbio.2022.08.010. Epub 2022 Sep 28. Ultrasound Med Biol. 2022. PMID: 36180313 Free article.
High-intensity focused ultrasound transducers operating at 4 MHz based on lead-free piezoceramics from the sodium bismuth titanate (NBT) family are described. ...It is found that the lead-free material from the NBT family is also a promising alt
High-intensity focused ultrasound transducers operating at 4 MHz based on lead-free piezoceramics from th
Design of HIFU Transducers for Generating Specified Nonlinear Ultrasound Fields.
Rosnitskiy PB, Yuldashev PV, Sapozhnikov OA, Maxwell AD, Kreider W, Bailey MR, Khokhlova VA. Rosnitskiy PB, et al. IEEE Trans Ultrason Ferroelectr Freq Control. 2017 Feb;64(2):374-390. doi: 10.1109/TUFFC.2016.2619913. Epub 2016 Oct 20. IEEE Trans Ultrason Ferroelectr Freq Control. 2017. PMID: 27775904 Free PMC article.
Various clinical applications of high-intensity focused ultrasound have different requirements for the pressure levels and degree of nonlinear waveform distortion at the focus. ...The accuracy of the method and its applicability to cases of strongly …
Various clinical applications of high-intensity focused ultrasound have different requirements for the pressure …
Ultrasound thrombolysis.
Siegel RJ, Luo H. Siegel RJ, et al. Ultrasonics. 2008 Aug;48(4):312-20. doi: 10.1016/j.ultras.2008.03.010. Epub 2008 Mar 28. Ultrasonics. 2008. PMID: 18462769 Review.
Ultrasound energy for thrombolysis dates back to 1976. Trubestein et al. demonstrated first in vitro that a rigid wire delivery low frequency ultrasound energy could disrupt clot. ...Subsequently, four basic approaches to ultrasonic thrombolysis have been pursued--t
Ultrasound energy for thrombolysis dates back to 1976. Trubestein et al. demonstrated first in vitro that a rigid wire delivery low f
Design, Development, and Operation of a Low-Intensity Focused Ultrasound Pulsation (LIFUP) System for Clinical Use.
Schafer ME, Spivak NM, Korb AS, Bystritsky A. Schafer ME, et al. IEEE Trans Ultrason Ferroelectr Freq Control. 2021 Jan;68(1):54-64. doi: 10.1109/TUFFC.2020.3006781. Epub 2020 Dec 23. IEEE Trans Ultrason Ferroelectr Freq Control. 2021. PMID: 32746201
Noninvasive low-intensity focused ultrasound pulsation (LIFUP) neuromodulation provides a unique approach to both investigating and treating the brain. This work describes a well-calibrated, simple-to-use ultrasound stimulation system for neuromodulation stud …
Noninvasive low-intensity focused ultrasound pulsation (LIFUP) neuromodulation provides a unique approach to both investigatin …
Design, characterization and evaluation of a laser-guided focused ultrasound system for preclinical investigations.
Anastasiadis P, Mohammadabadi A, Fishman MJ, Smith JA, Nguyen BA, Hersh DS, Frenkel V. Anastasiadis P, et al. Biomed Eng Online. 2019 Mar 28;18(1):36. doi: 10.1186/s12938-019-0656-z. Biomed Eng Online. 2019. PMID: 30922312 Free PMC article.
BACKGROUND: The clinical applications of transcranial focused ultrasound continue to expand and include ablation as well as drug delivery applications in the brain, where treatments are typically guided by MRI. ...METHODS: The system comprised an off-the-shel …
BACKGROUND: The clinical applications of transcranial focused ultrasound continue to expand and include ablation as wel …
Design and validation of an MR-conditional robot for transcranial focused ultrasound surgery in infants.
Price KD, Sin VW, Mougenot C, Pichardo S, Looi T, Waspe AC, Drake JM. Price KD, et al. Med Phys. 2016 Sep;43(9):4983. doi: 10.1118/1.4955174. Med Phys. 2016. PMID: 27587029
Current clinical and research focused ultrasound systems lack the capability to perform neonatal transcranial surgeries due to either range of motion or dexterity requirements. A novel robotic system is proposed to position a focused ultrasound tran
Current clinical and research focused ultrasound systems lack the capability to perform neonatal transcranial surgeries due to …
System and method for applying physiotherapeutic focused ultrasound.
Portilla Tuesta G, Montero de Espinosa F. Portilla Tuesta G, et al. Ultrasonics. 2022 Apr;121:106693. doi: 10.1016/j.ultras.2022.106693. Epub 2022 Jan 25. Ultrasonics. 2022. PMID: 35093669 Free article.
Despite many years of clinical use of ultrasound, the results of different reviews of controlled trials on the efficacy of ultrasound physical therapy for different musculoskeletal injuries continue to question its efficacy. ...The object of this work is the design, …
Despite many years of clinical use of ultrasound, the results of different reviews of controlled trials on the efficacy of ultraso
Design and Optimization of Ultrasound Phased Arrays for Large-Scale Ultrasound Neuromodulation.
Ilham SJ, Kashani Z, Kiani M. Ilham SJ, et al. IEEE Trans Biomed Circuits Syst. 2021 Dec;15(6):1454-1466. doi: 10.1109/TBCAS.2021.3133133. Epub 2022 Feb 17. IEEE Trans Biomed Circuits Syst. 2021. PMID: 34874867 Free PMC article.
Low-intensity transcranial focused ultrasound stimulation (tFUS), as a noninvasive neuromodulation modality, has shown to be effective in animals and even humans with improved millimeter-scale spatial resolution compared to its noninvasive counterparts. ...To achiev …
Low-intensity transcranial focused ultrasound stimulation (tFUS), as a noninvasive neuromodulation modality, has shown to be e …
Design and experiment of 256-element ultrasound phased array for noninvasive focused ultrasound surgery.
Lu M, Wan M, Xu F, Wang X, Chang X. Lu M, et al. Ultrasonics. 2006 Dec 22;44 Suppl 1:e325-30. doi: 10.1016/j.ultras.2006.07.015. Epub 2006 Aug 11. Ultrasonics. 2006. PMID: 16949119
A 256-element phased array high intensity focused ultrasound system has been designed and constructed in our laboratory. ...Then, the design guidelines of 256-element spherical-section focused ultrasound phased array and 256-channel drive …
A 256-element phased array high intensity focused ultrasound system has been designed and constructed in our lab …
Minimally invasive therapeutic ultrasound: Ultrasound-guided ultrasound ablation in neuro-oncology.
Belzberg M, Mahapatra S, Perdomo-Pantoja A, Chavez F, Morrison K, Xiong KT, Gamo NJ, Restaino S, Thakor N, Yazdi Y, Iyer R, Tyler B, Theodore N, Luciano MG, Brem H, Groves M, Cohen AR, Manbachi A. Belzberg M, et al. Ultrasonics. 2020 Dec;108:106210. doi: 10.1016/j.ultras.2020.106210. Epub 2020 Jun 20. Ultrasonics. 2020. PMID: 32619834 Free PMC article.
Focused ultrasound can often be performed noninvasively; however, it is more difficult to carry out in neuro-oncological tumors, as ultrasound is dramatically attenuated while propagating through the skull. ...CONCLUSION: We developed and validated an ultr
Focused ultrasound can often be performed noninvasively; however, it is more difficult to carry out in neuro-oncological tumor
248 results