Format
Sort by
Items per page

Send to

Choose Destination

Search results

Items: 1 to 20 of 133

1.

Evaluation of the Effect of Air Polishing With Different Abrasive Powders on the Roughness of Implant Abutment Surface: An In Vitro Study.

Biazussi BR, Perrotti V, D'Arcangelo C, Elias CN, Bianchini MA, Tumedei M, de Vasconcellos DK.

J Oral Implantol. 2019 Jun;45(3):202-206. doi: 10.1563/aaid-joi-D-18-00156. Epub 2019 Mar 15.

PMID:
30875272
2.

Correlation between Implant Geometry, Bone Density, and the Insertion Torque/Depth Integral: A Study on Bovine Ribs.

Di Stefano DA, Arosio P, Perrotti V, Iezzi G, Scarano A, Piattelli A.

Dent J (Basel). 2019 Mar 5;7(1). pii: E25. doi: 10.3390/dj7010025.

3.

Effects of air abrasive decontamination on titanium surfaces: A systematic review of in vitro studies.

Moharrami M, Perrotti V, Iaculli F, Love RM, Quaranta A.

Clin Implant Dent Relat Res. 2019 Apr;21(2):398-421. doi: 10.1111/cid.12747. Epub 2019 Mar 5.

PMID:
30838790
4.

Effectiveness of Different Commercial Chlorhexidine-Based Mouthwashes After Periodontal and Implant Surgery: A Systematic Review.

Chye RML, Perrotti V, Piattelli A, Iaculli F, Quaranta A.

Implant Dent. 2019 Feb;28(1):74-85. doi: 10.1097/ID.0000000000000854.

PMID:
30648980
5.

Bacterial leakage in external hexagon implants with and without the interposition of a sealing-connector.

Rizzo R, Tripodi D, Iaculli F, Piatelli A, Iezzi G, Perrotti V, D'Ercole S.

Am J Dent. 2018 Oct;31(5):234-238.

PMID:
30346668
6.

Rehabilitation of Postextractive Socket in the Premaxilla: A 12-Year Study on 27 Titanium Plasma Spray Resorbable Calcium Phosphate Coated Single Implants.

Perrotti V, Vozza I, Tumedei M, Pompa G, Iaculli F, Quaranta A.

Implant Dent. 2018 Aug;27(4):452-460. doi: 10.1097/ID.0000000000000790.

PMID:
30028390
7.

The effect of undersizing and tapping on bone to implant contact and implant primary stability: A histomorphometric study on bovine ribs.

Di Stefano DA, Perrotti V, Greco GB, Cappucci C, Arosio P, Piattelli A, Iezzi G.

J Adv Prosthodont. 2018 Jun;10(3):227-235. doi: 10.4047/jap.2018.10.3.227. Epub 2018 Jun 12.

8.

Influence of the Buccal Bone Crest Width on Peri-Implant Hard and Soft Tissues Dimensions: A Histomorphometric Study in Humans.

Omori Y, Iezzi G, Perrotti V, Piattelli A, Ferri M, Nakajima Y, Botticelli D.

Implant Dent. 2018 Aug;27(4):415-423. doi: 10.1097/ID.0000000000000772.

PMID:
29878920
9.

Four Stable and Functioning Dental Implants Retrieved for Fracture After 14 and 17 Years from the Same Patient: A Histologic and Histomorphometric Report.

Botticelli D, Perrotti V, Piattelli A, Iezzi G.

Int J Periodontics Restorative Dent. 2019 January/February;39(1):83–88. doi: 10.11607/prd.3116. Epub 2018 Mar 7.

PMID:
29513778
10.

Sinus augmentation and concomitant implant placement in low bone-density sites. A retrospective study on an undersized drilling protocol and primary stability.

Arosio P, Greco GB, Zaniol T, Iezzi G, Perrotti V, Di Stefano DA.

Clin Implant Dent Relat Res. 2018 Apr;20(2):151-159. doi: 10.1111/cid.12558. Epub 2017 Nov 22.

PMID:
29164788
11.

Regenerative properties of collagenated porcine bone grafts in human maxilla: demonstrative study of the kinetics by synchrotron radiation microtomography and light microscopy.

Giuliani A, Iezzi G, Mazzoni S, Piattelli A, Perrotti V, Barone A.

Clin Oral Investig. 2018 Jan;22(1):505-513. doi: 10.1007/s00784-017-2139-6. Epub 2017 Jun 2.

PMID:
28577053
12.

A stability evaluation of a novel titanium dental implant/interconnected porous hydroxyapatite complex under functional loading conditions.

Doi K, Kubo T, Kajihara S, Makihara Y, Oue H, Oki Y, Perrotti V, Piattelli A, Akagawa Y, Tsuga K.

Dent Mater J. 2017 Sep 26;36(5):647-653. doi: 10.4012/dmj.2016-346. Epub 2017 May 30.

13.

The Impact of Residual Subgingival Cement on Biological Complications Around Dental Implants: A Systematic Review.

Quaranta A, Lim ZW, Tang J, Perrotti V, Leichter J.

Implant Dent. 2017 Jun;26(3):465-474. doi: 10.1097/ID.0000000000000593. Review.

PMID:
28437366
14.

Molecular, Cellular and Pharmaceutical Aspects of Bone Grafting Materials and Membranes During Maxillary Sinus-lift Procedures. Part 1: A General Overview.

Iezzi G, Piattelli A, Giuliani A, Mangano C, Manzon L, Degidi M, Iaculli F, Scarano A, Filippone A, Perrotti V.

Curr Pharm Biotechnol. 2017;18(1):19-32. doi: 10.2174/1389201017666161221155237. Review.

PMID:
28003001
15.

Molecular, Cellular and Pharmaceutical Aspects of Bone Grafting Materials and Membranes During Maxillary Sinus-lift Procedures. Part 2: Detailed Characteristics of the Materials.

Iezzi G, Piattelli A, Giuliani A, Mangano C, Barone A, Manzon L, Degidi M, Scarano A, Filippone A, Perrotti V.

Curr Pharm Biotechnol. 2017;18(1):33-44. doi: 10.2174/1389201017666161202104002.

PMID:
27915982
16.

Implant-Abutment Contact Surfaces and Microgap Measurements of Different Implant Connections Under 3-Dimensional X-Ray Microtomography.

Scarano A, Valbonetti L, Degidi M, Pecci R, Piattelli A, de Oliveira PS, Perrotti V.

Implant Dent. 2016 Oct;25(5):656-62. doi: 10.1097/ID.0000000000000465.

PMID:
27551879
17.

Update of Surgical Techniques for Maxillary Sinus Augmentation: A Systematic Literature Review.

Carreño Carreño J, Aguilar-Salvatierra A, Gómez-Moreno G, García Carreño EM, Menéndez López-Mateos ML, Perrotti V, Piattelli A, Calvo-Guirado JL, Menéndez-Núñez M.

Implant Dent. 2016 Dec;25(6):839-844. Review.

PMID:
27540841
18.

Periimplant Bone Response in Human-Retrieved, Clinically Stable, Successful, and Functioning Dental Implants After a Long-Term Loading Period: A Report of 17 Cases From 4 to 20 Years.

Iezzi G, Piattelli A, Mangano C, Degidi M, Testori T, Vantaggiato G, Fiera E, Frosecchi M, Floris P, Perroni R, Ravera L, Moreno GG, De Martinis E, Perrotti V.

Implant Dent. 2016 Jun;25(3):380-6. doi: 10.1097/ID.0000000000000415.

PMID:
27002775
19.

Anatomical Remodeling of Buccal Bone Plate in 35 Premaxillary Post-Extraction Immediately Restored Single TPS Implants: 10-Year Radiographic Investigation.

Quaranta A, Perrotti V, Putignano A, Malchiodi L, Vozza I, Calvo Guirado JL.

Implant Dent. 2016 Apr;25(2):186-92. doi: 10.1097/ID.0000000000000375.

PMID:
26836125
20.

Degree of bacterial microleakage at the implant-abutment junction in Cone Morse tapered implants under loaded and unloaded conditions.

Tripodi D, D'Ercole S, Iaculli F, Piattelli A, Perrotti V, Iezzi G.

J Appl Biomater Funct Mater. 2015 Dec 18;13(4):e367-71. doi: 10.5301/jabfm.5000247.

PMID:
26660625

Supplemental Content

Loading ...
Support Center