Format
Sort by
Items per page

Send to

Choose Destination

Search results

Items: 19

1.

OSL dosimetric properties and efficiency of Brazilian natural calcium fluoride pellets.

Malthez ALMC, Marczewska B, Ferreira F, Umisedo NK, Nowak T, Bilski P, Yoshimura EM.

Appl Radiat Isot. 2018 May;135:166-170. doi: 10.1016/j.apradiso.2018.01.041. Epub 2018 Jan 31.

PMID:
29413833
2.

High-Dose TL Dosimetry of Reactor Neutrons.

Obryk B, Malik K, Bilski P, Igielski A, Dankowski J, Kurowski A, Prokopowicz R, Pytel K.

Radiat Prot Dosimetry. 2018 Aug 1;180(1-4):235-239. doi: 10.1093/rpd/ncx244.

PMID:
29136230
3.

Molecular and Vibrational Dynamics in the Cholesterol-Lowering Agent Lovastatin: Solid-State NMR, Inelastic Neutron Scattering, and Periodic DFT Study.

Bilski P, Drużbicki K, Jenczyk J, Mielcarek J, Wąsicki J.

J Phys Chem B. 2017 Apr 6;121(13):2776-2787. doi: 10.1021/acs.jpcb.7b01090. Epub 2017 Mar 23.

PMID:
28282493
4.

The relationship between reorientational molecular motions and phase transitions in [Mg(H2O)6](BF4)2, studied with the use of (1)H and (19)F NMR and FT-MIR.

Mikuli E, Hetmańczyk J, Grad B, Kozak A, Wąsicki JW, Bilski P, Hołderna-Natkaniec K, Medycki W.

J Chem Phys. 2015 Feb 14;142(6):064507. doi: 10.1063/1.4907372.

PMID:
25681923
5.

NUNDO: a numerical model of a human torso phantom and its application to effective dose equivalent calculations for astronauts at the ISS.

Puchalska M, Bilski P, Berger T, Hajek M, Horwacik T, Körner C, Olko P, Shurshakov V, Reitz G.

Radiat Environ Biophys. 2014 Nov;53(4):719-27. doi: 10.1007/s00411-014-0560-7. Epub 2014 Aug 15.

6.

The MATROSHKA experiment: results and comparison from extravehicular activity (MTR-1) and intravehicular activity (MTR-2A/2B) exposure.

Berger T, Bilski P, Hajek M, Puchalska M, Reitz G.

Radiat Res. 2013 Dec;180(6):622-37. doi: 10.1667/RR13148.1. Epub 2013 Nov 19.

PMID:
24252101
7.

Cosmic radiation exposure of biological test systems during the EXPOSE-E mission.

Berger T, Hajek M, Bilski P, Körner C, Vanhavere F, Reitz G.

Astrobiology. 2012 May;12(5):387-92. doi: 10.1089/ast.2011.0777.

8.

Method of thermoluminescent measurement of radiation doses from micrograys up to a megagray with a single LiF:Mg,Cu,P detector.

Obryk B, Bilski P, Olko P.

Radiat Prot Dosimetry. 2011 Mar;144(1-4):543-7. doi: 10.1093/rpd/ncq339. Epub 2010 Nov 3.

PMID:
21051430
9.

Astronaut's organ doses inferred from measurements in a human phantom outside the international space station.

Reitz G, Berger T, Bilski P, Facius R, Hajek M, Petrov V, Puchalska M, Zhou D, Bossler J, Akatov Y, Shurshakov V, Olko P, Ptaszkiewicz M, Bergmann R, Fugger M, Vana N, Beaujean R, Burmeister S, Bartlett D, Hager L, Pálfalvi J, Szabó J, O'Sullivan D, Kitamura H, Uchihori Y, Yasuda N, Nagamatsu A, Tawara H, Benton E, Gaza R, McKeever S, Sawakuchi G, Yukihara E, Cucinotta F, Semones E, Zapp N, Miller J, Dettmann J.

Radiat Res. 2009 Feb;171(2):225-35. doi: 10.1667/RR1559.1.

PMID:
19267549
10.

A procedural model of the diagnosis and treatment of osteoid osteoma in children.

Snela S, Bielak R, Cnota H, Bilski P.

Ortop Traumatol Rehabil. 2002 Dec 30;4(6):703-7.

PMID:
18034099
11.

Difficulties in treating chondrolysis and avascular necrosis of the hip in adolescent patients.

Bilski P, Snela S.

Ortop Traumatol Rehabil. 2006 Feb 28;8(1):34-40.

PMID:
17603453
12.

Absorbed dose measurements of a handheld 50 kVP X-ray source in water with thermoluminescence dosemeters.

Soares C, Drupieski C, Wingert B, Pritchett G, Pagonis V, O'Brien M, Sliski A, Bilski P, Olko P.

Radiat Prot Dosimetry. 2006;120(1-4):78-82. Epub 2006 May 30.

PMID:
16735571
13.

Analysis of spectrally resolved thermoluminescence of LiF:Mg,Cu,P detectors by the surface fitting method using algorithm for unrestricted peak positions.

Mandowska E, Mandowski A, Bilski P, Swiatek J.

Radiat Prot Dosimetry. 2006;119(1-4):89-92. Epub 2006 Apr 13.

PMID:
16614088
14.

[Assessment of orthopedic and sonographic hip examinations in the first days after birth based on research conducted in neonatal units and outpatient clinics].

Rydzak B, Snela S, Bielak R, Naszkiewicz B, Bilski P.

Chir Narzadow Ruchu Ortop Pol. 2004;69(2):105-7. Polish.

PMID:
15307381
15.

Post-dilatation intravascular brachytherapy trials on hypercholesterolemic rabbits using 32P-phosphate solutions in angioplasty balloons.

Walichiewicz P, Wilczek K, Petelenz B, Jacheć W, Jochem J, Tomasik A, Bilski P, Gaca P, Banaszczuk J, Ihnatowicz J, Wodniecki J.

Cardiovasc Intervent Radiol. 2004 Jan-Feb;27(1):42-50.

PMID:
15109228
16.

Modeling the response of thermoluminescence detectors exposed to low- and high-LET radiation fields.

Olko P, Bilski P, Budzanowski M, Waligórski MP, Reitz G.

J Radiat Res. 2002 Dec;43 Suppl:S59-62.

17.

Physical and chemical limitations to preparation of beta radioactive stents by direct neutron activation.

Petelenz B, Rajchel B, Bilski P, Misiak R, Bartyzel M, Wilczek K, Alber D.

Biomaterials. 2003 Feb;24(3):427-33.

PMID:
12423597
18.

Cryogenic dual-mode resonator for a fly-wheel oscillator for a caesium frequency standard.

Tobar ME, Hartnett JG, Ivanov EN, Cros D, Bilski P.

IEEE Trans Ultrason Ferroelectr Freq Control. 2002 Oct;49(10):1349-55.

PMID:
12403136
19.

Post-stenting intravascular brachytherapy trials on hypercholesterolemic rabbits using 32P liquid sources: implications for prevention of in-stent restenosis.

Wilczek K, Walichiewicz P, Petelenz B, Jache W, Jochem J, Tomasik A, Bilski P, Snietura M, Wodniecki J.

Cardiovasc Intervent Radiol. 2002 Jul-Aug;25(4):307-13. Epub 2002 Jun 4.

PMID:
12042990

Supplemental Content

Loading ...
Support Center