Format
Sort by
Items per page

Send to

Choose Destination

Search results

Items: 1 to 20 of 31

1.

Failure load and stress analysis of orthodontic miniscrews with different transmucosal collar diameter.

Sfondrini MF, Gandini P, Alcozer R, Vallittu PK, Scribante A.

J Mech Behav Biomed Mater. 2018 Nov;87:132-137. doi: 10.1016/j.jmbbm.2018.07.032. Epub 2018 Jul 24.

PMID:
30059839
2.

Reliability of Orthodontic Miniscrews: Bending and Maximum Load of Different Ti-6Al-4V Titanium and Stainless Steel Temporary Anchorage Devices (TADs).

Scribante A, Montasser MA, Radwan ES, Bernardinelli L, Alcozer R, Gandini P, Sfondrini MF.

Materials (Basel). 2018 Jul 5;11(7). pii: E1138. doi: 10.3390/ma11071138.

3.

Diode Laser-Assisted Surgical Therapy for Early Treatment of Oral Mucocele in a Newborn Patient: Case Report and Procedures Checklist.

Vitale MC, Sfondrini MF, Croci GA, Paulli M, Carbone L, Gandini P, Scribante A.

Case Rep Dent. 2018 Apr 24;2018:3048429. doi: 10.1155/2018/3048429. eCollection 2018.

4.

Computerized Casts for Orthodontic Purpose Using Powder-Free Intraoral Scanners: Accuracy, Execution Time, and Patient Feedback.

Sfondrini MF, Gandini P, Malfatto M, Di Corato F, Trovati F, Scribante A.

Biomed Res Int. 2018 Apr 23;2018:4103232. doi: 10.1155/2018/4103232. eCollection 2018.

5.

VATS thymectomy for early stage thymoma and myasthenia gravis: combined right-sided uniportal and left-sided three-portal approach.

Infante M, Benato C, Giovannetti R, Bonadiman C, Canneto B, Falezza G, Lonardoni A, Gandini P.

J Vis Surg. 2017 Oct 18;3:144. doi: 10.21037/jovs.2017.09.01. eCollection 2017.

6.

Bending Properties of Fiber-Reinforced Composites Retainers Bonded with Spot-Composite Coverage.

Sfondrini MF, Gandini P, Tessera P, Vallittu PK, Lassila L, Scribante A.

Biomed Res Int. 2017;2017:8469090. doi: 10.1155/2017/8469090. Epub 2017 Oct 10.

7.

Spot-Bonding and Full-Bonding Techniques for Fiber Reinforced Composite (FRC) and Metallic Retainers.

Scribante A, Gandini P, Tessera P, Vallittu PK, Lassila L, Sfondrini MF.

Int J Mol Sci. 2017 Oct 4;18(10). pii: E2096. doi: 10.3390/ijms18102096.

8.

Dental Hygiene and Orthodontics: Effect of Ultrasonic Instrumentation on Bonding Efficacy of Different Lingual Orthodontic Brackets.

Scribante A, Sfondrini MF, Collesano V, Tovt G, Bernardinelli L, Gandini P.

Biomed Res Int. 2017;2017:3714651. doi: 10.1155/2017/3714651. Epub 2017 Aug 17.

9.

Orthodontic Metallic Lingual Brackets: The Dark Side of the Moon of Bond Failures?

Sfondrini MF, Gandini P, Gioiella A, Zhou FX, Scribante A.

J Funct Biomater. 2017 Jul 7;8(3). pii: E27. doi: 10.3390/jfb8030027.

10.

Sella turcica bridging and dental anomalies: is there an association?

Scribante A, Sfondrini MF, Cassani M, Fraticelli D, Beccari S, Gandini P.

Int J Paediatr Dent. 2017 Nov;27(6):568-573. doi: 10.1111/ipd.12301. Epub 2017 Apr 7.

PMID:
28387468
11.

Epidemiological survey of different clinical techniques of orthodontic bracket debonding and enamel polishing.

Sfondrini MF, Scribante A, Fraticelli D, Roncallo S, Gandini P.

J Orthod Sci. 2015 Oct-Dec;4(4):123-7. doi: 10.4103/2278-0203.173425.

12.

Effects of nanofillers on mechanical properties of fiber-reinforced composites polymerized with light-curing and additional postcuring.

Scribante A, Massironi S, Pieraccini G, Vallittu P, Lassila L, Sfondrini MF, Gandini P.

J Appl Biomater Funct Mater. 2015 Oct 16;13(3):e296-9. doi: 10.5301/jabfm.5000226.

PMID:
26108426
13.

A 15-month evaluation of bond failures of orthodontic brackets bonded with direct versus indirect bonding technique: a clinical trial.

Menini A, Cozzani M, Sfondrini MF, Scribante A, Cozzani P, Gandini P.

Prog Orthod. 2014 Dec 30;15:70. doi: 10.1186/s40510-014-0070-9.

14.

Reliability of skeletal maturity analysis using the cervical vertebrae maturation method on dedicated software.

Padalino S, Sfondrini MF, Chenuil L, Scudeller L, Gandini P.

Int Orthod. 2014 Dec;12(4):483-93. doi: 10.1016/j.ortho.2014.10.003. Epub 2014 Nov 20.

PMID:
25457719
15.

Clinical evaluation of bond failures and survival between mandibular canine-to-canine retainers made of flexible spiral wire and fiber-reinforced composite.

Sfondrini MF, Fraticelli D, Castellazzi L, Scribante A, Gandini P.

J Clin Exp Dent. 2014 Apr 1;6(2):e145-9. doi: 10.4317/jced.51379. eCollection 2014 Apr.

16.

Finishing effectiveness of different archwires using SmartClip™ self-ligating brackets: a clinical study.

Ferrari S, Bellincampi M, Sfondrini MF, Caprioglio A, Gandini P.

Int Orthod. 2014 Mar;12(1):125-38. doi: 10.1016/j.ortho.2013.12.001. Epub 2014 Jan 21. English, French.

PMID:
24456630
17.

The influence of no-primer adhesives and anchor pylons bracket bases on shear bond strength of orthodontic brackets.

Scribante A, Sfondrini MF, Fraticelli D, Daina P, Tamagnone A, Gandini P.

Biomed Res Int. 2013;2013:315023. doi: 10.1155/2013/315023. Epub 2013 Aug 4.

18.

Opening and closure forces of sliding mechanisms of different self-ligating brackets.

Gandini P, Orsi L, Sfondrini MF, Scribante A.

J Appl Oral Sci. 2013;21(3):231-4. doi: 10.1590/1679-7757201300063.

19.

Flexural strengths of conventional and nanofilled fiber-reinforced composites: a three-point bending test.

Sfondrini MF, Massironi S, Pieraccini G, Scribante A, Vallittu PK, Lassila LV, Gandini P.

Dent Traumatol. 2014 Feb;30(1):32-5. doi: 10.1111/edt.12055. Epub 2013 Jun 30.

PMID:
23809886
20.

Shear bond strength of orthodontic brackets and disinclusion buttons: effect of water and saliva contamination.

Sfondrini MF, Fraticelli D, Gandini P, Scribante A.

Biomed Res Int. 2013;2013:180137. doi: 10.1155/2013/180137. Epub 2013 May 15.

Supplemental Content

Loading ...
Support Center