Format
Sort by
Items per page

Send to

Choose Destination

Search results

Items: 1 to 20 of 52

1.

MPI Phantom Study with A High-Performing Multicore Tracer Made by Coprecipitation.

Kratz H, Mohtashamdolatshahi A, Eberbeck D, Kosch O, Hauptmann R, Wiekhorst F, Taupitz M, Hamm B, Schnorr J.

Nanomaterials (Basel). 2019 Oct 16;9(10). pii: E1466. doi: 10.3390/nano9101466.

2.

Resveratrol-Coated Balloon Catheters in Porcine Coronary and Peripheral Arteries.

Kamann S, Haase T, Stolzenburg N, Löchel M, Peters D, Schnorr J.

Int J Mol Sci. 2019 May 9;20(9). pii: E2285. doi: 10.3390/ijms20092285.

3.

Very small superparamagnetic iron oxide nanoparticles: Long-term fate and metabolic processing in atherosclerotic mice.

Poller WC, Pieber M, Boehm-Sturm P, Ramberger E, Karampelas V, Möller K, Schleicher M, Wiekhorst F, Löwa N, Wagner S, Schnorr J, Taupitz M, Stangl K, Stangl V, Ludwig A.

Nanomedicine. 2018 Nov;14(8):2575-2586. doi: 10.1016/j.nano.2018.07.013. Epub 2018 Sep 1.

PMID:
30179669
4.

Renal Denervation by Transaortic Periarterial Ethanol Injection: An Experimental Study in Porcines.

Freyhardt P, Schütze J, Donners R, Schnorr J, Stolzenburg N, Rinnenthal JL, Penzkofer T, Hamm B, Günther RW, Streitparth F.

Cardiovasc Intervent Radiol. 2018 Dec;41(12):1943-1951. doi: 10.1007/s00270-018-2045-6. Epub 2018 Aug 7.

PMID:
30088063
5.

Novel magnetic multicore nanoparticles designed for MPI and other biomedical applications: From synthesis to first in vivo studies.

Kratz H, Taupitz M, Ariza de Schellenberger A, Kosch O, Eberbeck D, Wagner S, Trahms L, Hamm B, Schnorr J.

PLoS One. 2018 Jan 4;13(1):e0190214. doi: 10.1371/journal.pone.0190214. eCollection 2018.

6.

Synthesis of europium-doped VSOP, customized enhancer solution and improved microscopy fluorescence methodology for unambiguous histological detection.

de Schellenberger AA, Hauptmann R, Millward JM, Schellenberger E, Kobayashi Y, Taupitz M, Infante-Duarte C, Schnorr J, Wagner S.

J Nanobiotechnology. 2017 Oct 10;15(1):71. doi: 10.1186/s12951-017-0301-6.

7.

Inflammation-induced brain endothelial activation leads to uptake of electrostatically stabilized iron oxide nanoparticles via sulfated glycosaminoglycans.

Berndt D, Millward JM, Schnorr J, Taupitz M, Stangl V, Paul F, Wagner S, Wuerfel JT, Sack I, Ludwig A, Infante-Duarte C.

Nanomedicine. 2017 May;13(4):1411-1421. doi: 10.1016/j.nano.2017.01.010. Epub 2017 Jan 25.

PMID:
28131884
8.

Renal denervation by CT-guided periarterial injection of hyperosmolar saline, vincristine, paclitaxel and guanethidine in a pig model.

Freyhardt P, Donners R, Riemert A, Schnorr J, Stolzenburg N, Rinnenthal JL, Bernhardt U, Hamm B, Günther RW, Streitparth F.

EuroIntervention. 2017 Apr 7;12(18):e2262-e2270. doi: 10.4244/EIJ-D-15-00354.

9.

Labeling of mesenchymal stem cells for MRI with single-cell sensitivity.

Ariza de Schellenberger A, Kratz H, Farr TD, Löwa N, Hauptmann R, Wagner S, Taupitz M, Schnorr J, Schellenberger EA.

Int J Nanomedicine. 2016 Apr 12;11:1517-35. doi: 10.2147/IJN.S101141. eCollection 2016.

10.

Paclitaxel-Coated Balloons: Investigation of Drug Transfer in Healthy and Atherosclerotic Arteries - First Experimental Results in Rabbits at Low Inflation Pressure.

Stolzenburg N, Breinl J, Bienek S, Jaguszewski M, Löchel M, Taupitz M, Speck U, Wagner S, Schnorr J.

Cardiovasc Drugs Ther. 2016 Jun;30(3):263-70. doi: 10.1007/s10557-016-6658-1.

11.

Synthesis of acid-stabilized iron oxide nanoparticles and comparison for targeting atherosclerotic plaques: evaluation by MRI, quantitative MPS, and TEM alternative to ambiguous Prussian blue iron staining.

Scharlach C, Kratz H, Wiekhorst F, Warmuth C, Schnorr J, Genter G, Ebert M, Mueller S, Schellenberger E.

Nanomedicine. 2015 Jul;11(5):1085-95. doi: 10.1016/j.nano.2015.01.002. Epub 2015 Feb 4.

PMID:
25659644
12.

MR-guided high-focused ultrasound for renal sympathetic denervation-a feasibility study in pigs.

Freyhardt P, Heckmann L, Beck A, Stolzenburg N, Schnorr J, Kamp J, Rinnenthal JL, Hamm B, Günther RW, Streitparth F.

J Ther Ultrasound. 2014 Aug 4;2:12. doi: 10.1186/2050-5736-2-12. eCollection 2014.

13.

Direct coupling of annexin A5 to VSOP yields small, protein-covered nanoprobes for MR imaging of apoptosis.

Figge L, Appler F, Chen HH, Sosnovik DE, Schnorr J, Seitz O, Taupitz M, Hamm B, Schellenberger E.

Contrast Media Mol Imaging. 2014 Jul-Aug;9(4):291-9. doi: 10.1002/cmmi.1575.

14.

In vivo therapy monitoring of experimental rheumatoid arthritis in rats using near-infrared fluorescence imaging.

Vollmer S, Gemeinhardt I, Vater A, Schnorr B, Schnorr J, Voigt J, Ebert B.

J Biomed Opt. 2014 Mar;19(3):36011. doi: 10.1117/1.JBO.19.3.036011.

15.

XTEN-annexin A5: XTEN allows complete expression of long-circulating protein-based imaging probes as recombinant alternative to PEGylation.

Haeckel A, Appler F, Figge L, Kratz H, Lukas M, Michel R, Schnorr J, Zille M, Hamm B, Schellenberger E.

J Nucl Med. 2014 Mar;55(3):508-14. doi: 10.2967/jnumed.113.128108. Epub 2014 Feb 18.

16.

Author's reply: To PMID 23450179.

Taupitz M, Schnorr J, Wagner S.

Int J Nanomedicine. 2013;8:4675-6. No abstract available.

PMID:
24383105
17.

Synthetic routes to magnetic nanoparticles for MPI.

Kratz H, Eberbeck D, Wagner S, Taupitz M, Schnorr J.

Biomed Tech (Berl). 2013 Dec;58(6):509-15. doi: 10.1515/bmt-2012-0057. Review.

PMID:
23950566
18.

Iron oxide magnetic nanoparticles highlight early involvement of the choroid plexus in central nervous system inflammation.

Millward JM, Schnorr J, Taupitz M, Wagner S, Wuerfel JT, Infante-Duarte C.

ASN Neuro. 2013;5(1):e00110.

19.

Contrast-enhanced MR imaging of atherosclerosis using citrate-coated superparamagnetic iron oxide nanoparticles: calcifying microvesicles as imaging target for plaque characterization.

Wagner S, Schnorr J, Ludwig A, Stangl V, Ebert M, Hamm B, Taupitz M.

Int J Nanomedicine. 2013;8:767-79. doi: 10.2147/IJN.S38702. Epub 2013 Feb 20.

20.

Imaging of magnetic microfield distortions allows sensitive single-cell detection.

Lindquist RL, Papazoglou S, Scharlach C, Waiczies H, Schnorr J, Taupitz M, Hamm B, Schellenberger E.

Mol Imaging. 2013 Mar-Apr;12(2):83-9.

PMID:
23415396

Supplemental Content

Loading ...
Support Center