Format
Sort by
Items per page

Send to

Choose Destination

Search results

Items: 9

1.

[Boundary-layer damping of traveling waves in a three-dimensional passive finite-element model of the human cochlea].

Böhnke F, Sigloch M.

Z Med Phys. 2020 Feb 21. pii: S0939-3889(19)30152-7. doi: 10.1016/j.zemedi.2019.12.001. [Epub ahead of print] German.

PMID:
32093906
2.

Electrical Stimulation in the Human Cochlea: A Computational Study Based on High-Resolution Micro-CT Scans.

Bai S, Encke J, Obando-Leitón M, Weiß R, Schäfer F, Eberharter J, Böhnke F, Hemmert W.

Front Neurosci. 2019 Dec 5;13:1312. doi: 10.3389/fnins.2019.01312. eCollection 2019.

3.

Influence of the Cochlear Implant Electrode Array Placement on the Current Spread in the Cochlea.

Schafer F, Enke J, Bohnke F, Hemmert W, Bai S.

Conf Proc IEEE Eng Med Biol Soc. 2018 Jul;2018:6145-6148. doi: 10.1109/EMBC.2018.8513666.

PMID:
30441737
4.

Effect of modeling parameters on the frequency response of the middle ear by means of finite element analysis.

Spiridon IF, Sakellarios AI, Rigas GA, Tagaris A, Bellos CV, Bibas A, Bohnke F, Iliopoulou D, Koutsouris D, Fotiadis DI.

Conf Proc IEEE Eng Med Biol Soc. 2015 Aug;2015:925-8. doi: 10.1109/EMBC.2015.7318514.

PMID:
26736414
5.

Reconstruction of cochlea based on micro-CT and histological images of the human inner ear.

Bellos C, Rigas G, Spiridon IF, Bibas A, Iliopoulou D, Böhnke F, Koutsouris D, Fotiadis DI.

Biomed Res Int. 2014;2014:485783. doi: 10.1155/2014/485783. Epub 2014 Aug 3.

6.

Simulations and Measurements of Human Middle Ear Vibrations Using Multi-Body Systems and Laser-Doppler Vibrometry with the Floating Mass Transducer.

Böhnke F, Bretan T, Lehner S, Strenger T.

Materials (Basel). 2013 Oct 22;6(10):4675-4688. doi: 10.3390/ma6104675.

7.

Three-dimensional representation of the human cochlea using micro-computed tomography data: presenting an anatomical model for further numerical calculations.

Braun K, Böhnke F, Stark T.

Acta Otolaryngol. 2012 Jun;132(6):603-13. doi: 10.3109/00016489.2011.653670. Epub 2012 Mar 4.

PMID:
22384791
8.

Bone conduction in a three-dimensional model of the cochlea.

Bohnke F, Arnold W.

ORL J Otorhinolaryngol Relat Spec. 2006;68(6):393-6. Epub 2006 Oct 26.

PMID:
17065835
9.

Representation of acoustic signals in the human cochlea in presence of a cochlear implant electrode.

Kiefer J, Böhnke F, Adunka O, Arnold W.

Hear Res. 2006 Nov;221(1-2):36-43. Epub 2006 Sep 7.

PMID:
16962268

Supplemental Content

Loading ...
Support Center