J Infect Dis. 1998 Feb;177(2):425-30.

Do in vitro susceptibility data predict the microbiologic response to amphotericin B? Results of a prospective study of patients with Candida fungemia.

Author information

1
University of Florida College of Medicine, VA Medical Center, Gainesville 32610, USA. nguyen.med@shands.ufl.edu

Abstract

Outcome for 105 patients with candidemia treated with amphotericin B was correlated with amphotericin B in vitro susceptibility results. Thirty-three patients had microbiologic failure, which was defined as persistence of Candida in the bloodstream despite > or = 3 days of amphotericin B. Amphotericin B minimum inhibitory concentrations (MICs) were determined by the National Committee for Clinical Laboratory Standards methodology. After determination of MICs, the minimal lethal concentrations (MLCs) were determined. The isolates tested yielded a narrow range of amphotericin B MICs (0.06-2 microg/mL); only 5% (5/105) exhibited MICs > or = 1 microg/mL. The MLC range, on the other hand, was significantly broader (0.125 to > 16 microg/mL); 24% (25/105) exhibited MLCs > or = 1 microg/mL. The strongest predictor for microbiologic failure was 48-h MLC (P < .001), followed by 24-h MLC (P = .03) and 48-h MIC (P = .11). A resistant break point for amphotericin B of > 1 microg/mL for MLC and > or = 1 microg/mL for MIC could be inferred from this study.

PMID:
9466531
DOI:
10.1086/514193
[Indexed for MEDLINE]