Format

Send to

Choose Destination
J Med Microbiol. 1997 May;46(5):419-24.

Widely used, commercially available Chlamydia pneumoniae antigen contaminated with mycoplasma.

Author information

1
Department of Clinical Microbiology, Academic Hospital Dijkzigt, Rotterdam, The Netherlands.

Abstract

Mycoplasma contamination was detected in a widely used commercially available Chlamydia pneumoniae antigen preparation. Contamination was studied with a mycoplasma group-specific 16S rRNA polymerase chain reaction (PCR) and sequence analysis. Several lots of the purified C. pneumoniae antigen from the Washington Research Foundation appeared to be contaminated with the same Mycoplasma species, which appeared to be closely related to M. arginini. Antigen slides prepared for the detection of chlamydia antibodies by MRL Diagnostics were contaminated with the same Mycoplasma sp. Chlamydia antigen slides from Labsystems OY and two chlamydia complement fixation reagents (Virion International Distribution Ltd and Behring Werke) were not contaminated. It is concluded that commercially available C. pneumoniae antigens may contain mycoplasma antigens as well. Although the impact of such mycoplasma contamination on the results of chlamydia serology may not be significant, routine screening of all antigen preparations obtained by tissue culture before their distribution and use is recommended.

PMID:
9152039
DOI:
10.1099/00222615-46-5-419
[Indexed for MEDLINE]

Supplemental Content

Full text links

Icon for Ingenta plc
Loading ...