Format

Send to

Choose Destination
Clin Sci (Lond). 1996 Nov;91(5):633-8.

Chromatographic method for the determination of non-transferrin-bound iron suitable for use on the plasma and bronchoalveolar lavage fluid of preterm babies.

Author information

1
University Department of Paediatrics, Sheffield Children's Hospital, U.K.

Abstract

1. Non-protein-bound iron has been implicated in the aetiology of chronic lung disease of prematurity. 2. The modification of a method for the measurement of non-transferrin-bound iron in small volumes of plasma and bronchoalveolar lavage fluid from preterm babies is described. 3. The assay runs with a good degree of precision and a lower limit of detection of 0.02 mumol/l. 4. Non-transferrin-bound iron was detected in 50% of plasma samples and 11% of bronchoalveolar lavage fluid samples collected over the first week of life from babies born prematurely.

PMID:
8942403
DOI:
10.1042/cs0910633
[Indexed for MEDLINE]