Ophthalmic Physiol Opt. 1993 Jan;13(1):3-7.

Population distribution of stereoscopic ability.

Author information

1
Department of Molecular and Cell Biology, University of California, Berkeley 94720.

Abstract

Of 188 unselected biology students participating in one or both of two tests measuring stereoscopic depth detection ability, 183 (97.3%) were able to see a depth difference at horizontal disparities of 2.3 min arc or smaller. At least 80% could detect depth differences at 30 sec arc disparity. These findings indicate that most people are able to take advantage of the increasing utilization of stereoscopic displays.