Format

Send to

Choose Destination
J Hosp Infect. 1995 Jan;29(1):65-8.

Stethoscope contamination in the neonatal intensive care unit.

Author information

1
Department of Paediatrics and Child Health, Leeds General Infirmary, UK.

Abstract

The level of contamination of stethoscopes used in a neonatal intensive care unit was studied, along with the practices used for cleaning these items. A policy of alcohol cleaning was introduced and the effect of this change on the level of bacterial growth was observed after a six-week period. It was found that 71% of stethoscopes had a significant bacterial growth and that this was reduced to 30% after the cleaning procedure change (P < 0.05). Stethoscopes and other equipment are a potential source of nosocomial infection on the neonatal intensive care unit.

PMID:
7738341
DOI:
10.1016/0195-6701(95)90294-5
[Indexed for MEDLINE]