Format

Send to

Choose Destination
See comment in PubMed Commons below
Radiology. 1995 Dec;197(3):619-26.

Ovarian cancer: staging with CT and MR imaging.

Author information

1
Department of Radiology, University of California School of Medicine, San Francisco 94143-0628, USA.

Abstract

PURPOSE:

To evaluate ovarian cancer staging and tumor resectability with computed tomography (CT) or magnetic resonance (MR) imaging.

MATERIALS AND METHODS:

Eighty-two women underwent CT (n = 43) or MR imaging (n = 50); eleven of these 82 underwent both. Imaging was performed within 4 weeks of surgical staging. Radiologic, surgical, and histopathologic findings were compared.

RESULTS:

Overall staging accuracy was similar for CT and MR imaging (77% [33 of 43] vs 78% [39 of 50]). Evaluation of pelvic cancer extent was better with MR imaging than with CT. There was no difference in detection of abdominal disease. Most mesenteric and small-bowel implants were not detected with either CT or MR imaging. For CT, the positive predictive value for cancer nonresectability was 100% (three of three patients); the negative predictive value was 92% (37 of 40 patients). The positive and negative predictive values for MR imaging were 91% (10 of 11 patients) and 97% (38 of 39 patients).

CONCLUSION:

While the staging accuracy of both CT and MR imaging is only moderate, prediction of tumor resectability is excellent.

[Indexed for MEDLINE]