A novel objective method for discriminating pathological and physiological colorectal uptake in the lower abdominal region using whole-body dynamic 18F-FDG-PET

Ann Nucl Med. 2023 Oct;37(10):561-571. doi: 10.1007/s12149-023-01857-6. Epub 2023 Jul 31.

Abstract

Objectives: To investigate whether the center-of-mass shift distance (CMSD) analysis on whole-body dynamic positron emission tomography (WBD-PET) with continuous bed motion is an objective index for discriminating pathological and physiological uptake in the lower abdominal colon.

Methods: We retrospectively analyzed the CMSD in 39 patients who underwent delayed imaging to detect incidental focal uptake that was difficult to determine as pathological and physiological on a conventional early-PET (early) image reconstructed by 5-phase WBD-PET images. The CMSD between each phase of WBD-PET images and between conventional early and delayed (two-phase) PET images were classified into pathological and physiological uptake groups based on endoscopic histology or other imaging diagnostics. The diagnostic performance of CMSD analysis on WBD-PET images was evaluated by receiver operator characteristic (ROC) analysis and compared to that of two-phase PET images.

Results: A total of 66 incidental focal uptake detected early image were classified into 19 and 47 pathological and physiological uptake groups, respectively. The CMSD on WBD-PET and two-phase PET images in the pathological uptake group was significantly lower than that in the physiological uptake group (p < 0.01), respectively. The sensitivity, specificity, and accuracy in CMSD analysis on WBD-PET images at the optimal cutoff of 5.2 mm estimated by the Youden index were 94.7%, 89.4%, and 89.4%, respectively, which were not significantly different (p = 0.74) from those of two-phase PET images.

Conclusions: The CMSD analysis on WBD-PET was useful in discriminating pathological and physiological colorectal uptake in the lower abdominal region, and its diagnostic performance was comparable to that of two-phase PET images. We suggested that CMSD analysis on WBD-PET images would be a novel objective method to omit unnecessary additional delayed imaging.

Keywords: Center-of-mass shift distance (CMSD); Diagnostic performance; Pathological uptake; Physiological uptake; Whole-body dynamic positron emission tomography (WBD-PET).