Determination of p-hydroxybenzoic acid esters in cosmetics by liquid chromatography with ultraviolet and fluorescence detection

J Assoc Off Anal Chem. 1988 Jul-Aug;71(4):823-5.

Abstract

A simple, precise, and accurate liquid chromatographic method with both ultraviolet (UV) and fluorescence detection is described for the determination of methyl, ethyl, propyl, and butyl p-hydroxybenzoates (PHBA-esters) in cosmetics. sec-Butyl p-hydroxybenzoate is added to the sample as an internal standard. Then the PHBA-esters are extracted with ether, the ether is evaporated to dryness, and the residue is dissolved in 60% (v/v) acetonitrile. The acetonitrile solution is passed through a Sep-Pak C18 cartridge to remove co-extracted lipids. PHBA-esters are determined by reverse-phase liquid chromatography with UV detection at 254 nm and fluorescence detection at ex 280 nm, em 305 nm. The mobile phase is acetonitrile-water (35 + 65). The method was linear over the concentration range of 0.005-0.15 mg/mL. Mean recoveries of each PHBA-ester were 98.9-102.7% (coefficients of variation less than or equal to 2.0%).

MeSH terms

  • Chromatography, Liquid
  • Cosmetics / analysis*
  • Hydroxybenzoates / analysis*
  • Indicators and Reagents
  • Spectrometry, Fluorescence
  • Spectrophotometry, Ultraviolet

Substances

  • Cosmetics
  • Hydroxybenzoates
  • Indicators and Reagents