Renal Stent Complications and Impact on Renal Function after Standard Fenestrated Endovascular Aneurysm Repair

Ann Vasc Surg. 2021 Apr:72:106-113. doi: 10.1016/j.avsg.2020.10.020. Epub 2020 Nov 27.

Abstract

Background: To report renal outcomes including long-term patency, secondary interventions, and related renal function after fenestrated endovascular aortic repair (fEVAR).

Methods: Single-center retrospective review of patients undergoing fEVAR between 2012 and 2018 using the Cook ZFEN device. Renal stent complications, defined as any stenosis, occlusion, kink, renal stent-related endoleak, and reinterventions were tabulated. Estimated glomerular filtration rate (eGFR) was estimated using the Modification of Diet in Renal Disease formula.

Results: During the study period, 114 patients underwent elective fEVAR. Of 329 total target vessels, 193 renal arteries were stented (133 Atrium iCAST, 60 Gore VBX). Technical success was achieved in 97.4%, and the mean follow-up was 23.3 months. Seventeen renal complications occurred in 14 patients (12.3%), including 4 occlusions, 9 stenosis, 3 dislocations, and 1 type III endoleak. All stent complications underwent endovascular reintervention with a median hospital stay of 1 day (0-10) and a technical success of 94.2%. One patient suffered renal hemorrhage that warranted embolization. Patients with occlusion were treated the day of diagnosis, and mean time from diagnosis to intervention for stenosis was 21.5 days. Estimated primary patency was 92.1 % and 81.5% at 24 and 48 months, respectively. On multivariate analysis, larger native renal artery diameter was the only independent protective factor against patency loss (HR 0.23 (0.09-0.59)). Secondary patency at latest follow-up was 99.4%. Mean eGFR was not significantly different at latest follow-up between patients with renal complications versus those without (43.75 vs. 55.58 mL/min/1.73 m2, P = 0.09). Comparing patients with and without renal stent complications, 81.4% and 72.7% of patients had stable or improved renal disease by chronic kidney disease staging compared with baseline (P = 0.51).

Conclusions: fEVAR is a durable option for the treatment of juxtarenal aortic aneurysms and is associated with excellent secondary patency. Renal stent complications have no significant impact on renal function, but smaller native renal arteries are at higher risk of stent-graft complications.

MeSH terms

  • Aged
  • Aged, 80 and over
  • Aortic Aneurysm, Abdominal / diagnostic imaging
  • Aortic Aneurysm, Abdominal / physiopathology
  • Aortic Aneurysm, Abdominal / surgery*
  • Blood Vessel Prosthesis Implantation* / adverse effects
  • Blood Vessel Prosthesis Implantation* / instrumentation
  • Blood Vessel Prosthesis*
  • Endovascular Procedures* / adverse effects
  • Endovascular Procedures* / instrumentation
  • Female
  • Glomerular Filtration Rate
  • Humans
  • Male
  • Middle Aged
  • Postoperative Complications / etiology*
  • Postoperative Complications / physiopathology
  • Postoperative Complications / therapy
  • Renal Artery / diagnostic imaging
  • Renal Artery / physiopathology
  • Renal Artery / surgery*
  • Retrospective Studies
  • Risk Assessment
  • Risk Factors
  • Stents*
  • Time Factors
  • Treatment Outcome
  • Vascular Patency