Impact of obesity on adverse in-hospital outcomes in patients undergoing percutaneous mitral valve edge-to-edge repair using MitraClip® procedure - Results from the German nationwide inpatient sample

Nutr Metab Cardiovasc Dis. 2020 Jul 24;30(8):1365-1374. doi: 10.1016/j.numecd.2020.04.009. Epub 2020 Apr 18.

Abstract

Background and aim: The number of percutaneous edge-to-edge mitral regurgitation (MR) valve repairs with MitraClip® implantations increased exponentially in recent years. Studies have suggested an obesity survival paradox in patients with cardiovascular diseases. We investigated the influence of obesity on adverse in-hospital outcomes in patients with MitraClip® implantation.

Methods and results: We analyzed data on characteristics of patients and in-hospital outcomes for all percutaneous mitral valve repairs using the edge-to-edge MitraClip®-technique in Germany 2011-2015 stratified for obesity vs. normal-weight/over-weight. The nationwide inpatient sample comprised 13,563 inpatients undergoing MitraClip® implantations. Among them, 1017 (7.5%) patients were coded with obesity. Obese patients were younger (75 vs.77 years,P < 0.001), more often female (45.4% vs.39.5%,P < 0.001), had more often heart failure (87.1% vs.79.2%,P < 0.001) and renal insufficiency (67.0% vs.56.4%,P < 0.001). Obese and non-obese patients were comparable regarding major adverse cardiac and cerebrovascular events (MACCE) and in-hospital death. The combined endpoint of cardio-pulmonary resuscitation (CPR), mechanical ventilation and death was more often reached in non-obese than in obese patients with a trend towards significance (20.6%vs.18.2%,P = 0.066). Obesity was an independent predictor of reduced events regarding the combined endpoint of CPR, mechanical ventilation and death (OR 0.75, 95%CI 0.64-0.89,P < 0.001), but not for reduced in-hospital mortality (P = 0.355) or reduced MACCE rate (P = 0.108). Obesity class III was associated with an elevated risk for pulmonary embolism (OR 5.66, 95%CI 1.35-23.77,P = 0.018).

Conclusions: We observed an obesity paradox regarding the combined endpoint of CPR, mechanical ventilation and in-hospital death in patients undergoing MitraClip® implantation, but our results failed to confirm an impact of obesity on in-hospital survival or MACCE.

Keywords: Edge-to-edge; MitraClip; Mitral valve regurgitation; Obesity; Percutaneus mitral valve repair; Survival.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Aged
  • Aged, 80 and over
  • Cardiac Catheterization / adverse effects
  • Cardiac Catheterization / instrumentation*
  • Cardiac Catheterization / mortality
  • Databases, Factual
  • Female
  • Germany / epidemiology
  • Heart Valve Prosthesis Implantation / adverse effects
  • Heart Valve Prosthesis Implantation / instrumentation*
  • Heart Valve Prosthesis Implantation / mortality
  • Heart Valve Prosthesis*
  • Hospital Mortality
  • Humans
  • Male
  • Mitral Valve Insufficiency / diagnosis
  • Mitral Valve Insufficiency / mortality
  • Mitral Valve Insufficiency / surgery*
  • Obesity / diagnosis
  • Obesity / epidemiology*
  • Obesity / mortality
  • Postoperative Complications / mortality
  • Postoperative Complications / therapy
  • Prosthesis Design
  • Risk Assessment
  • Risk Factors
  • Time Factors
  • Treatment Outcome