Indian J Ophthalmol. 2019 Jul;67(7):1155-1157. doi: 10.4103/ijo.IJO_1703_18.

Silicone band loop myopexy for myopic strabismus fixus.

Author information

1
Advanced Eye Center, Postgraduate Institute of Medical Education and Research, Chandigarh, India.

Abstract

Myopic strabismus fixus causes inability of the eye to elevate and abduct in the setting of a myopic superotemporally herniated globe. We report a novel surgical technique to manage an 18-year-old male with myopic strabismus fixus. Radiological imaging demonstrated a nasally deviated superior rectus (SR) and inferiorly displaced lateral rectus (LR). Silicone band assisted myopexy of SR and LR was done along with anchoring them to the sclera with a dacron suture. The patient had satisfactory alignment postoperatively and did not require any intervention over 1-year follow-up.

KEYWORDS:

Loop myopexy; silicone; strabismus fixus

PMID:
31238434
DOI:
10.4103/ijo.IJO_1703_18