Clinical Targets for Continuous Glucose Monitoring Data Interpretation: Recommendations From the International Consensus on Time in Range

Diabetes Care. 2019 Aug;42(8):1593-1603. doi: 10.2337/dci19-0028. Epub 2019 Jun 8.

Abstract

Improvements in sensor accuracy, greater convenience and ease of use, and expanding reimbursement have led to growing adoption of continuous glucose monitoring (CGM). However, successful utilization of CGM technology in routine clinical practice remains relatively low. This may be due in part to the lack of clear and agreed-upon glycemic targets that both diabetes teams and people with diabetes can work toward. Although unified recommendations for use of key CGM metrics have been established in three separate peer-reviewed articles, formal adoption by diabetes professional organizations and guidance in the practical application of these metrics in clinical practice have been lacking. In February 2019, the Advanced Technologies & Treatments for Diabetes (ATTD) Congress convened an international panel of physicians, researchers, and individuals with diabetes who are expert in CGM technologies to address this issue. This article summarizes the ATTD consensus recommendations for relevant aspects of CGM data utilization and reporting among the various diabetes populations.

Publication types

  • Research Support, N.I.H., Extramural
  • Research Support, Non-U.S. Gov't
  • Review

MeSH terms

  • Blood Glucose / analysis*
  • Blood Glucose Self-Monitoring / standards
  • Consensus
  • Data Accuracy
  • Data Interpretation, Statistical*
  • Diabetes Mellitus / blood*
  • Glycated Hemoglobin / analysis
  • Humans
  • Internationality
  • Patient Care Planning*
  • Practice Guidelines as Topic*
  • Reference Values
  • Time Factors

Substances

  • Blood Glucose
  • Glycated Hemoglobin A
  • hemoglobin A1c protein, human