Format

Send to

Choose Destination
Clin Physiol Funct Imaging. 2019 Sep;39(5):327-338. doi: 10.1111/cpf.12582. Epub 2019 Jun 6.

A new vessel segmentation algorithm for robust blood flow quantification from two-dimensional phase-contrast magnetic resonance images.

Author information

1
Department of Clinical Sciences Lund, Clinical Physiology, Skane University Hospital, Lund University, Lund, Sweden.
2
Department of Biomedical Engineering, Faculty of Engineering, Lund University, Lund, Sweden.
3
Department of Clinical Sciences Lund, Diagnostic Radiology, Skane University Hospital, Lund University, Lund, Sweden.
4
Department of Health Sciences, Physiotherapy, Lund University, Lund, Sweden.
5
Laboratory of Computing, Medical Informatics and Biomedical - Imaging Technologies, School of Medicine, Aristotle University of Thessaloniki, Thessaloniki, Greece.
6
Wallenberg Center for Molecular Medicine, Lund University, Lund, Sweden.

Abstract

Blood flow measurements in the ascending aorta and pulmonary artery from phase-contrast magnetic resonance images require accurate time-resolved vessel segmentation over the cardiac cycle. Current semi-automatic segmentation methods often involve time-consuming manual correction, relying on user experience for accurate results. The purpose of this study was to develop a semi-automatic vessel segmentation algorithm with shape constraints based on manual vessel delineations for robust segmentation of the ascending aorta and pulmonary artery, to evaluate the proposed method in healthy volunteers and patients with heart failure and congenital heart disease, to validate the method in a pulsatile flow phantom experiment, and to make the method freely available for research purposes. Algorithm shape constraints were extracted from manual reference delineations of the ascending aorta (n = 20) and pulmonary artery (n = 20) and were included in a semi-automatic segmentation method only requiring manual delineation in one image. Bias and variability (bias ± SD) for flow volume of the proposed algorithm versus manual reference delineations were 0·0 ± 1·9 ml in the ascending aorta (n = 151; seven healthy volunteers; 144 heart failure patients) and -1·7 ± 2·9 ml in the pulmonary artery (n = 40; 25 healthy volunteers; 15 patients with atrial septal defect). Interobserver bias and variability were lower (P = 0·008) for the proposed semi-automatic method (-0·1 ± 0·9 ml) compared to manual reference delineations (1·5 ± 5·1 ml). Phantom validation showed good agreement between the proposed method and timer-and-beaker flow volumes (0·4 ± 2·7 ml). In conclusion, the proposed semi-automatic vessel segmentation algorithm can be used for efficient analysis of flow and shunt volumes in the aorta and pulmonary artery.

KEYWORDS:

PC-MRI; ascending aorta; interobserver variability; phantom experiments; pulmonary artery; semi-automatic analysis

PMID:
31102479
PMCID:
PMC6852024
DOI:
10.1111/cpf.12582
[Indexed for MEDLINE]
Free PMC Article

Supplemental Content

Full text links

Icon for Wiley Icon for PubMed Central
Loading ...
Support Center