Format

Send to

Choose Destination
Exp Eye Res. 2019 Feb;179:102-105. doi: 10.1016/j.exer.2018.11.004. Epub 2018 Nov 8.

Physiological pressure enhances the formation of tight junctions in engineered and native corneal endothelium.

Author information

1
Centre de recherche du Centre hospitalier universitaire (CHU) de Québec, Université Laval, axe médecine régénératrice, Hôpital du Saint-Sacrement, Québec, QC, Canada; Centre de recherche en organogénèse expérimentale de l'Université Laval / LOEX, Québec, QC, Canada; Département d'Ophtalmologie et d'oto-rhino-laryngologie-chirurgie cervico-faciale, Faculté de médecine, Université Laval, Québec, QC, Canada.
2
Centre de recherche de l'Hôpital Maisonneuve-Rosemont (HMR) and Département d'ophtalmologie, Université de Montréal, Montréal, QC, Canada.
3
Centre de recherche du Centre hospitalier universitaire (CHU) de Québec, Université Laval, axe médecine régénératrice, Hôpital du Saint-Sacrement, Québec, QC, Canada; Centre de recherche en organogénèse expérimentale de l'Université Laval / LOEX, Québec, QC, Canada; Département d'Ophtalmologie et d'oto-rhino-laryngologie-chirurgie cervico-faciale, Faculté de médecine, Université Laval, Québec, QC, Canada. Electronic address: stephanie.proulx@fmed.ulaval.ca.

Abstract

Cells and tissues are influenced by environmental conditions. In vivo, the corneal endothelium is subjected to hydrostatic intraocular pressure (IOP) and to the hydrokinetic pressure of the moving aqueous humor in the anterior chamber. In this paper, we used a corneal bioreactor to recreate the IOP condition and investigated the effect of the in vivo hydrodynamic environment of corneal endothelial cells on the formation of tight junctions. Native ex vivo corneas and engineered corneal endothelia subjected to pressure showed an increase in ZO-1 expression at the cell periphery. Pressure also improved the corneal transparency of engineered and native corneas. Corneal thickness was accordingly reduced from 926 ± 70 μm to 651 ± 70 μm for the engineered corneal endothelium and from 847 ± 27 μm to 571 ± 23 μm for the native endothelium. These results suggest that the hydrodynamic pressure of the anterior chamber is important for the cell junction integrity of the corneal endothelium.

KEYWORDS:

Corneal bioreactor; Corneal endothelium; Pressure; Tight junctions; ZO-1

PMID:
30414972
DOI:
10.1016/j.exer.2018.11.004
[Indexed for MEDLINE]