Format

Send to

Choose Destination
Rev Inst Med Trop Sao Paulo. 2018 Oct 25;60:e61. doi: 10.1590/S1678-9946201860061.

Assessment and comparison of bacterial load levels determined by quantitative amplifications in blood culture-positive and negative neonatal sepsis.

Author information

1
Universidade Federal de Mato Grosso, Hospital Universitário Julio Muller, Laboratório de Análises Clínicas, Divisão de Microbiologia, Cuiabá, Mato Grosso, Brazil.
2
Universidade de São Paulo, Instituto de Medicina Tropical de São Paulo, Laboratório de Soroepidemiologia e Imunobiologia, São Paulo, São Paulo, Brazil.
3
Universidade de São Paulo, Faculdade de Medicina, Departamento de Moléstias Infecciosas e Parasitárias, LIM 48, São Paulo, São Paulo, Brazil.
4
Universidade Federal do Mato Grosso, Faculdade de Medicina, Departamento de Pediatria, Cuiabá, Mato Grosso, Brazil.
5
Universidade de São Paulo, Faculdade de Medicina, Departamento de Pediatria, São Paulo, São Paulo, Brazil.
6
Universidade de São Paulo, Faculdade de Medicina, Hospital das Clínicas, Instituto da Criança, Laboratório de Pediatria Clínica, LIM 36, São Paulo, São Paulo, Brazil.

Abstract

Bacterial sepsis remains a major cause of mortality and blood cultures are the gold standard of laboratory diagnosis even though they lack sensitivity in neonates. Culturenegative sepsis, also known as clinical sepsis, has long been considered a diagnosis in neonatal intensive care units because, as well as culture-positive infants, culture-negative neonates have worse prognosis in comparison with non-infected ones. Quantitative amplifications are used to detect bacterial infections in neonates but results are considered only in a qualitative way (positive or negative). The aim of the present study was to determine and compare bacterial load levels in blood culture-positive and culture-negative neonatal sepsis. Seventy neonates with clinical and laboratory evidence of infection admitted at three neonatal intensive care units were classified as blood culture-positive or culture-negative. Blood samples obtained at the same time of blood cultures had bacterial load levels assessed through a 16S rDNA qPCR. Blood cultures were positive in 29 cases (41.4%) and qPCR in 64 (91.4%). In the 29 culture-positive cases, 100% were also positive by qPCR, while in the 41 culture-negative cases, 35 (85.4%) were positive by qPCR. Bacterial load levels were in general < 50 CFU/mL, but were significantly higher in culture-positive cases (Mann-Whitney, p = 0.013), although clinical and laboratory findings were similar, excepting for deaths. In conclusion, the present study has shown that blood culture-negative neonates have lower bacteria load levels in their bloodstream when compared to blood culture-positive infants.

PMID:
30379228
PMCID:
PMC6201740
DOI:
10.1590/S1678-9946201860061
[Indexed for MEDLINE]
Free PMC Article

Supplemental Content

Full text links

Icon for Scientific Electronic Library Online Icon for PubMed Central
Loading ...
Support Center