Format

Send to

Choose Destination
Cancer Res Treat. 2018 Oct 15. doi: 10.4143/crt.2018.415. [Epub ahead of print]

Dummy Run of Quality Assurance Program before Prospective Study of Hippocampus-Sparing Whole-Brain Radiotherapy (HS-WBRT) and Simultaneous Integrated Boost (SIB) for Multiple Brain Metastases from Non-Small Cell Lung Cancer: Korean Radiation Oncology Group (KROG) 17-06 Study.

Author information

1
Department of Radiation Oncology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea.
2
Department of Radiation Oncology, Gachon University Gil Medical Center, Incheon, Korea.
3
Department of Radiation Oncology, Keimyung University Dongsan Medical Center, Daegu, Korea.
4
Department of Radiation Oncology, Kyung Hee University Hospital at Gangdong, Seoul, Korea.
5
Proton Therapy Center, National Cancer Center, Goyang, Korea.
6
Department of Radiation Oncology, Korea University Guro Hospital, Seoul, Korea.
7
Department of Radiation Oncology, Catholic University of Daegu School of Medicine, Daegu, Korea.
8
Department of Radiation Oncology, Seoul National University Hospital, Seoul, Korea.
9
Department of Radiation Oncology, College of Medicine, The Catholic University of Korea, Seoul, Korea.
10
Department of Radiation Oncology, Ajou University School of Medicine, Suwon, Korea.
11
Department of Radiation Oncology, Yeungnam University College of Medicine, Daegu, Korea.
12
Department of Radiation Oncology, Uijeongbu St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Uijeongbu, Korea.
13
Department of Radiation Oncology, Ewha Womans University School of Medicine, Seoul, Korea.
14
Department of Radiation Oncology, Jeju National University School of Medicine, Jeju, Korea.
15
Department of Radiation Oncology, Chungbuk National University College of Medicine, Cheongju, Korea.
16
Department of Radiation Oncology, School of Medicine, Kyungpook National University Daegu, Korea.
17
Department of Radiation Oncology, Inje University School of Medicine, Busan, Korea.
18
Department of Medical Device Management and Research, SAIHST, Sungkyunkwan University, Seoul, Korea.

Abstract

Purpose:

Lung Cancer Subcommittee of Korean Radiation Oncology Group (KROG) has recently launched a prospective clinical trial (KROG 17-06) of hippocampus-sparing whole brain radiotherapy (HS-WBRT) with simultaneous integrated boost (SIB) in treating multiple brain metastases from non-small cell lung cancer. In order to improve trial quality, dummy run studies among the participating institutions were designed. This work reported the results of two-step dummy run study of the KROG 17-06 protocol.

Materials and Methods:

Two steps tested hippocampus contouring variability and radiation therapy planning compliance. In the first step, the variation of the hippocampus delineation was investigated for two representative cases using the Dice similarity coefficients. In the second step, the participating institutions were requested to generate a HS-WBRT with SIB treatment plan for another representative case. The compliance of the treatment plans to the planning protocol was evaluated.

Results:

In the first step, the median Dice similarity coefficients of the hippocampus contours for two other dummy run cases changed from 0.669 (range, 0.073 to 0.712) to 0.690 (range, 0.522 to 0.750) and from 0.291 (range, 0.219 to 0.522) to 0.412 (range, 0.264 to 0.598) after providing the hippocampus contouring feedback. In the second step, with providing additional plan priority and extended dose constraints to the target volumes and normal structures, we observed the improved compliance of the treatment plans to the planning protocol.

Conclusion:

The dummy run studies demonstrated the notable inter-institutional variability in delineating the hippocampus and treatment plan generation, which could be decreased through feedback from the trial center.

KEYWORDS:

Dummy run; Hippocampus-sparing whole brain radiotherapy (HS-WBRT); Multi-institutional study; Non-small cell lung carcinoma; QA program

PMID:
30322229
DOI:
10.4143/crt.2018.415
Free full text

Supplemental Content

Full text links

Icon for Publishing M2Community
Loading ...
Support Center