Abstract

INTRODUCTION:

Inadequate validation, floor/ceiling effects, and time constraints limit utilization of standardized patient-reported outcome measures. We aimed to validate Patient-reported Outcomes Measurement Information System (PROMIS) computer adaptive tests (CATs) for patients treated surgically for a lumbar disk herniation.

METHODS:

PROMIS, CATs, Oswestry Disability Index, and Short Form-12 measures were administered to 78 patients treated with lumbar microdiskectomy for symptomatic disk herniation with radiculopathy.

RESULTS:

PROMIS CATs demonstrated convergent validity with legacy measures; PROMIS scores were moderately to highly correlated with the Oswestry Disability Index and Short Form-12 physical component scores (r = 0.41 and 0.78, respectively). PROMIS CATs demonstrated similar responsiveness to change compared with legacy measures. On average, the PROMIS CATs were completed in 2.3 minutes compared with 5.7 minutes for legacy measures.

DISCUSSION:

The PROMIS CATs demonstrate convergent and known groups' validity and are comparable in responsiveness to legacy measures. These results suggest similar utility and improved efficiency of PROMIS CATs compared with legacy measures.

LEVELS OF EVIDENCE:

Level II.